Filters · 3 active
Manufacturer:
LG
SAMSUNG
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(4)
AUX
(6)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(10)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(112)
EQUATION
(0)
FUJI ELECTRIC
(17)
FUJITSU
(54)
Fujitsu Atlantic
(19)
GENERAL
(12)
GREE
(0)
GSS
(0)
HAIER
(51)
HEC
(0)
HEIWA
(0)
HISENSE
(5)
HITACHI
(14)
IVT
(0)
Inventor
(8)
KAYSUN
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(43)
Mitsubishi Heavy Industries
(64)
NORD
(0)
Nobu
(0)
PANASONIC
(21)
RIELLO
(6)
Rotenso
(0)
THERMOR
(0)
TOSHIBA
(29)
Viessmann
(4)
Vulcano
(0)
WESTPOINT
(0)
YORK
(4)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
UUD1 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
UUD3 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
AC120RXADKG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.45 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.47 | -20° | 12.00 | 6.50 | |
|
AC140RXADKG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
UUD1 U30 / UV48F N20
UU
|
LG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.25 | 13.40 | 9.50 | ||
|
UUD3 U30 / UV48F N20
UU
|
LG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.25 | 13.40 | 9.50 | ||
|
AC100RXADKG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -20° | 10.00 | 5.20 | |
|
UUC1 U40 / UV36F N20
U4
|
LG | Ceiling suspended | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.70 | -10° | 9.50 | 5.50 | |
|
UUD1 U30 / UV42F N20
UU
|
LG | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.60 | 12.10 | 9.50 | ||
|
UUD3 U30 / UV42F N20
UU
|
LG | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.60 | 12.10 | 9.50 | ||
|
UUD1 U30 / UV36F N20
UU
|
LG | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 4.15 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UV36F N20
UU
|
LG | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 4.15 | -10° | 9.50 | 9.50 | |
|
UUB1 U20 / UV24F N10
UU
|
LG | Ceiling suspended | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.28 | -10° | 6.80 | 4.30 | |
|
UUB1 U20 / UV18F N10
UU
|
LG | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.29 | -10° | 5.00 | 4.20 | |
|
UUB1 U20 / UV30F N10
UU
|
LG | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.23 | -10° | 7.50 | 4.40 | |
|
UUA1 UL0 / UV18F N10
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 3.70 | -10° | 5.00 | 2.90 | |
|
UUD1 U30 / UV42FH N20
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.60 | 12.10 | 9.50 | ||
|
UUD3 U30 / UV42FH N20
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.30 | 3.60 | 12.10 | 9.50 | ||
|
UUC1 U40 / UV24F N10
U4
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.20 | 3.41 | -10° | 6.70 | 4.90 | |
|
UUD1 U30 / UV36FH N20
UU
|
LG | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 4.25 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UV36FH N20
UU
|
LG | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 4.25 | -10° | 9.50 | 9.50 | |
|
UUC1 U40 / UV30F N10
U4
|
LG | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.40 | 3.44 | -10° | 7.70 | 5.40 | |
|
UUB1 U20 / UV18FH N10
UU
|
LG | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.71 | -10° | 5.00 | 4.30 | |
|
UUC1 U40 / UV30FH N20
U4
|
LG | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.60 | 3.72 | -10° | 8.00 | 5.40 | |
|
UUC1 U40 / UV24FH N20
U4
|
LG | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.60 | 4.11 | -10° | 6.80 | 5.40 | |
|
AC071BXAPKG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
AC071BXAPNG/AC071BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.79 | -25° | 7.10 | 4.70 | |
|
AC052BXAPKG/AC052BNCPKG
CAC HEE
|
SAMSUNG | Ceiling suspended | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.80 | 4.58 | -25° | 5.00 | 4.00 |