Filters · 7 active
Manufacturer:
AIRCLASS
COLIBRI
Candy
EQUATION
LG
Vulcano
WESTPOINT
AIRWELL
(84)
ATLANTIC
(42)
AUX
(145)
BOSCH
(136)
BRYANT
(6)
Buderus
(38)
CARRIER
(159)
CIAT
(44)
CONFORT AIR
(4)
DAIKIN
(882)
DE DIETRICH
(20)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(139)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(409)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(74)
MIDEA
(843)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
PITSOS
(6)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
XTRON
(4)
YORK
(39)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
A5UW40GFA1 / ZMNW18GSKC0 / ZMNW24GSKC0
MU
|
LG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.81 | 3.10 | -15° | 10.00 | 8.00 | |
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
FM40AH.U34
MU
|
LG | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.30 | 12.10 | 8.60 | ||
|
FM41AH.U34
MU
|
LG | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.30 | 12.10 | 8.60 | ||
|
WIZO-09225.MH / WIZ-09225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 4.00 | -10° | 2.50 | 2.50 | |
|
UUD1 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD1 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUB1 U20 / CL18F N60
UU
|
LG | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.28 | -10° | 5.00 | 4.10 | |
|
WIMO-09225.MH / WIM-09225.MH
WIM 225
|
WESTPOINT | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
UUD1 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD1 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUC1 U40 / CM24F NA0
U4
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUA1 UL0 / UM12FH N10
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 4.10 | -10° | 3.50 | 2.80 | |
|
UUA1 UL0 / UM12FH NA0
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 4.10 | -10° | 3.50 | 2.80 | |
|
UUC1 U40 / UM36F N20
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
UUC1 U40 / UM36F N21
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
UE-EC 53 / UI-ECU M 53
Easy 3 Cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
APUW48GT3EA / APNW48GT3EA
UU
|
LG | Floor standing | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.41 | -10° | 13.40 | 11.00 | |
|
W24TI UEU / W24TI NEU
24TI
|
LG | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -15° | 7.00 | 5.20 | |
|
Virtus-12K-IN/Virtus-12K-OUT
Tundra Plus
|
EQUATION | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 3.81 | -10° | 3.50 | 2.80 | |
|
UE-L2C 70 / UI-L2CU M 70
Line cool
|
Vulcano | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
WIMO-24222.MH / WIM-24222.MH
WIM 222
|
WESTPOINT | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
Virtus-9K-IN/Virtus-9K-OUT
Tundra Plus
|
EQUATION | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
UE-L2C 26 / UI-L2CU M 26
Line cool
|
Vulcano | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
UUC1 U40 / CL24F N30
U4
|
LG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 3.90 | 3.52 | -10° | 6.80 | 5.40 | |
|
COLI18R8SHF/COLI18R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.00 | 3.31 | -10° | 5.20 | 4.10 | |
|
MU4R27 U42 / MJ09PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.70 | 3.80 | 3.60 | -10° | 6.80 | 6.70 | |
|
MU5R30 U42 / MJ12PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 3.80 | 3.40 | -10° | 7.30 | 6.90 | |
|
UE-L2C 35 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
Virtus-18K-IN/Virtus-18K-OUT
Tundra Plus
|
EQUATION | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
UUB1 U20 / US30F NR0
UU
|
LG | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.60 | -10° | 7.50 | 4.30 | |
|
RM2U15 U18 / RMN09 NSJ / RMN12 NSJ
MU
|
LG | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.09 | 4.00 | 4.38 | -10° | 4.10 | 3.60 | |
|
UUA1 UL0 / CT09F NR0
UU
|
LG | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 4.30 | -10° | 2.50 | 2.80 | |
|
UUA1 UL0 / CT12F NR0
UU
|
LG | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.71 | -10° | 3.40 | 2.80 | |
|
S3UM12EL26A / S3NM12EL26A
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA1 U18 / A12GA1 NSE
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2 U18 / A12GA2 NSE
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2U EEU / A12GA2N EEU
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2 U18T / A12GA2 NSET
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
UUD1 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
UUD3 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
UUC1 U40 / UM30F N10
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
UUC1 U40 / UM30F N11
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
UUC1 U40 / US36F NR0
U4
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 9.50 | 5.80 | |
|
Z2UW18GFA3 / ZMNW09GSJL2 / ZMNW09GSJL2
MU
|
LG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.05 | 3.57 | -10° | 5.20 | 3.70 | |
|
UE-L2C 53 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 |