Filters · 8 active
Manufacturer:
BOSCH
COLIBRI
Candy
Inventor
LG
Vulcano
WESTPOINT
AIRCLASS
(4)
AIRWELL
(18)
ATLANTIC
(22)
AUX
(27)
BRYANT
(0)
Buderus
(20)
CARRIER
(31)
CIAT
(4)
CONFORT AIR
(2)
DAIKIN
(255)
DE DIETRICH
(7)
EQUATION
(2)
FUJI ELECTRIC
(21)
FUJITSU
(58)
Fujitsu Atlantic
(28)
GENERAL
(54)
GREE
(41)
GSS
(0)
HAIER
(139)
HEC
(0)
HEIWA
(4)
HISENSE
(82)
HITACHI
(30)
IVT
(9)
KAYSUN
(9)
MIDEA
(197)
MITSUBISHI ELECTRIC
(76)
Mitsubishi Heavy Industries
(69)
NORD
(16)
Nobu
(0)
PANASONIC
(76)
PITSOS
(0)
RIELLO
(4)
Rotenso
(0)
SAMSUNG
(47)
THERMOR
(16)
TOSHIBA
(50)
Viessmann
(0)
XTRON
(0)
YORK
(2)
Mounting:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RM2U15 U18 / RMN09 NSJ / RMN12 NSJ
MU
|
LG | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.09 | 4.00 | 4.38 | -10° | 4.10 | 3.60 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
CL5000i 35 E / CL5000iU W 35 E
Climate 5000i
|
BOSCH | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.30 | 3.93 | -10° | 3.30 | 2.60 | |
|
P09SND NS0/P09SND U12A
U12A
|
LG | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.60 | 4.32 | -10° | 2.50 | 2.70 | |
|
CL4000i 26 E / CL4000iU W 26 E
Climate 4000i
|
BOSCH | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 4.21 | -10° | 2.90 | 2.40 | |
|
CL4000i 35 E / CL4000iU W 35 E
Climate 4000i
|
BOSCH | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.81 | -10° | 3.50 | 2.40 | |
|
CL4000i 52 E / CL4000iU W 52 E
Climate 4000i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.72 | -10° | 5.20 | 3.40 | |
|
CY-12QBIN-A/CY-12QBOUT-A
Candy Aira 2025
|
Candy | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 3.30 | 2.80 | |
|
DR2VO-12/DR2VI-12WFI
Dark
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
MFVO-12/MFVI-12WFI
Comfort
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
EMPVO-12/EMPVI-12WFI
Emperor
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
EMPVO(W)-12/EMPVI(W)-12WFI
Emperor
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
H12S1D NS1/H12S1D U12
U12A
|
LG | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.35 | -10° | 3.50 | 2.80 | |
|
H12S1DA NS1 / H12S1DA U12
U12A
|
LG | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.35 | -10° | 3.50 | 2.80 | |
|
CL6000iP 35 / CL6000iP W 35
Climate 6000iP
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL6000iP 35 / CL6000iP W 35 F
Climate 6000iP
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL5100i 25 HE/CL5100i W 25 HE
Climate 5100i
|
BOSCH | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.20 | -10° | 2.80 | 2.60 | |
|
CL5100i 35 HE/CL5100i W 35 HE
Climate 5100i
|
BOSCH | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 3.50 | 2.60 | |
|
COLI12D8SHF/COLI12D8SHC
Wall mounted
|
COLIBRI | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
LEUVO-12/LEUVI-12WFI
Leon
|
Inventor | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
LHUVO-12/LHUVI-12WFI
Leon
|
Inventor | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
LEUVOCP-12/LEUVICP-12WFI
Leon
|
Inventor | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
INVO-12/INVI-12WFI
Intellia
|
Inventor | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
WITO-12322.MH/WIT-12322.MH
WIT
|
WESTPOINT | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
WIMO-12325.MH / WIM-12325.MH
WIM 325
|
WESTPOINT | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
CL6001i 35 E / CL6001iU W 35 E
Climate 6000i
|
BOSCH | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
CL6102i 35 HE / CL6102i W 35 HE
Climate 6102i
|
BOSCH | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
CY-09QBIN-A/CY-09QBOUT-A
Candy Aira 2025
|
Candy | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 2.70 | 2.40 | |
|
DR2VO-09/DR2VI-09WFI
Dark
|
Inventor | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
MFVO-09/MFVI-09WFI
Comfort
|
Inventor | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
EMPVO-09/EMPVI-09WFI
Emperor
|
Inventor | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
EMPVO(W)-09/EMPVI(W)-09WFI
Emperor
|
Inventor | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.60 | 2.40 | |
|
CL6001i 70 E / CL6001iU W 70 E
Climate 6000i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
LEUVO-24/LEUVI-24WFI
Leon
|
Inventor | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
LHUVO-24/LHUVI-24WFI
Leon
|
Inventor | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
LEUVOCP -24/LEUVICP-24WFI
Leon
|
Inventor | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WIMO-24322.MH/WIM-24322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WITO-24322.MH/WIT-24322.MH
WIT
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WIMO-24326.MH / WIM-24326.MH
WIM 326
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
Z3UW24GFA3 / ZMNW07GSJL2 / ZMNW18GSKL2
MU
|
LG | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.01 | 4.30 | 3.69 | -10° | 6.80 | 4.90 | |
|
WIMO-18324.MH / WIM-18324.MH
WIM 324
|
WESTPOINT | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
WIMO-18326.MH / WIM-18326.MH
WIM 326
|
WESTPOINT | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
CL6001i 53 E / CL6001iU W 53 E
Climate 6000i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
LEUVO-18/LEUVI-18WFI
Leon
|
Inventor | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
LHUVO-18/LHUVI-18WFI
Leon
|
Inventor | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
LEUVOCP-18/LEUVICP-18WFI
Leon
|
Inventor | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WIMO-18322.MH/WIM-18322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WITO-18322.MH/WIT-18322.MH
WIT
|
WESTPOINT | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
CL6001i 26 E / CL6001iU W 26 E
Climate 6000i
|
BOSCH | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
CL6102i 25 HE / CL6102i W 25 HE
Climate 6102i
|
BOSCH | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 |