Filters · 1 active
Manufacturer:
LG
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PZ18EYN CSK1 / PZ18EYU CL21
U18A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 5.00 | 3.90 | |
|
EZ18CYN CSK1 / EZ18CYU CL21
U18A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 5.00 | 3.90 | |
|
EZ18CSN CSK1 / EZ18CSU CL21
U18A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 5.00 | 3.90 | |
|
AA18SB NS1 / AA18SP U18
U18A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.72 | -10° | 5.00 | 3.90 | |
|
PZ18EYN ASK1 / PZ18EYU AL21
U18A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 5.00 | 3.90 | |
|
EZ18CYN ASK1 / EZ18CYU AL21
U18A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 5.00 | 3.90 | |
|
DZ18RTK ASK1 / DZ18RTK AL21
U18A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 5.00 | 3.90 | |
|
PZ18AYN ASK1 / PZ18AYU AL21
U18A
|
LG | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 5.00 | 3.90 | |
|
UUD1 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD3 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZTNW60GALA1
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUC1 U40 / CM24F N10
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUC1 U40TK / ZBNW24GM1A1
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUC1 U40 / CM24F N11
U4
|
LG | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 3.90 | 3.31 | -10° | 6.80 | 5.40 | |
|
Z5UW36GFA3 / ZMNW12GSJL2 / ZMNW24GSKL2
MU
|
LG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.11 | 4.01 | 3.10 | -10° | 9.00 | 5.90 | |
|
UUB1 U20 / CL24F N30
UU
|
LG | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.11 | -10° | 6.80 | 4.20 | |
|
PZ24NYN CSK1 / PZ24NYU C241
U24A
|
LG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.45 | -10° | 6.60 | 4.90 | |
|
PZ24EYN CSK1 / PZ24EYU C241
U24A
|
LG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.45 | -10° | 6.60 | 4.90 | |
|
EZ24CYN CSK1 / EZ24CYU C241
U24A
|
LG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.45 | -10° | 6.60 | 4.90 | |
|
EZ24CSN CSK1 / EZ24CSU C241
U24A
|
LG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.45 | -10° | 6.60 | 4.90 | |
|
PZ24EYN ASK1 / PZ24EYU A241
U24A
|
LG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.45 | -10° | 6.60 | 4.90 | |
|
EZ24CYN ASK1 / EZ24CYU A241
U24A
|
LG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.45 | -10° | 6.60 | 4.90 | |
|
DZ24RTK ASK1 / DZ24RTK A241
U24A
|
LG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.45 | -10° | 6.60 | 4.90 | |
|
PZ24AYN ASK1 / PZ24AYU A241
U24A
|
LG | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.45 | -10° | 6.60 | 4.90 | |
|
S24EQ U24 / S24EQ NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
S3UW24K23BA / S3NW24K23BA
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
S24ET U24 / S24ET NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
AC24BH U24 / AC24BH NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
DC24RK U24 / DC24RK NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
AC24BK U24 / AC24BK NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
PC24SK U24 / PC24SK NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
AB24BK U24 / AB24BK NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
PC24ST U24 / PC24ST NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
S24EQ NSKS/S24EQ U24S
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
S24ET NSKS/S24ET U24S
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
S24EQ U24R / S24EQ NSKR
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
PC24SQ U24 / PC24SQ NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
H24S1D NS1/H24S1D U24
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
H24S1DA NS1 / H24S1DA U24
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
S24EC U24S / S24EC NSKS
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
PC24SC U24T / PC24SC NSKT
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
AC24BK NSKC/AC24BK U24C
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
PC24ST NSKC/PC24ST U24C
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
DC24RH U24 / DC24RH NSK
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.35 | -10° | 6.60 | 5.00 | |
|
S24ETK NSKS / S24ETK U24S
U24A
|
LG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.45 | -10° | 6.60 | 5.00 | |
|
Z4UW30GFA3 / ZMNW07GSJL2 / ZMNW24GSKL2
MU
|
LG | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.01 | 3.50 | -10° | 7.70 | 5.90 | |
|
UUD1 U30 / UT48F NA0
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
UUD3 U30 / UT48F NA0
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
UUD1 U30TK / ZTNW48GALA1
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
MU5R36 U36A0 / MJ18PC NSK0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.15 | 3.25 | -10° | 9.20 | 6.80 |