Filters · 3 active
Manufacturer:
Candy
MITSUBISHI ELECTRIC
AIRCLASS
(0)
AIRWELL
(2)
ATLANTIC
(4)
AUX
(0)
BOSCH
(4)
BRYANT
(0)
Buderus
(4)
CARRIER
(1)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
DAIKIN
(42)
EQUATION
(0)
FUJI ELECTRIC
(16)
FUJITSU
(43)
Fujitsu Atlantic
(21)
GENERAL
(19)
GREE
(3)
GSS
(0)
HAIER
(95)
HEC
(0)
HEIWA
(1)
HISENSE
(1)
HITACHI
(16)
IVT
(0)
Inventor
(11)
KAYSUN
(3)
LG
(18)
MIDEA
(40)
Mitsubishi Heavy Industries
(19)
NORD
(0)
Nobu
(0)
PANASONIC
(15)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(9)
THERMOR
(14)
TOSHIBA
(11)
Viessmann
(0)
Vulcano
(2)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MUZ-HJ25VA/MSZ-HJ25VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.62 | -10° | 2.50 | 1.90 | |
|
MUZ-HJ35VA/MSZ-HJ35VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.62 | -10° | 3.10 | 2.40 | |
|
PUZ-SM140VKA3/PEAD-SM140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA3/PEAD-SM140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3/PEAD-SM140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3/PEAD-SM140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA2/PEAD-SM140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA2/PEAD-SM140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
MXZ-3E54VA/MSZ-EF18VE3W(B)(S)/MSZ-EF35VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.54 | -15° | 5.30 | 4.80 | |
|
MXZ-4E72VA/MSZ-EF22VE3W(B)(S)/MSZ-EF50VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.70 | 3.80 | 3.11 | -15° | 6.40 | 5.50 | |
|
MXZ-3E68VA/MSZ-EF18VE3W(B)(S)/MSZ-EF50VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.50 | 3.80 | 2.97 | -15° | 6.20 | 5.10 | |
|
MXZ-4E83VA/MSZ-EF42VE3W(B)(S)/MSZ-EF42VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 2.97 | -15° | 7.00 | 5.90 | |
|
PUHZ-SHW230YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.81 | 3.51 | 3.47 | -25° | 19.00 | 23.00 | |
|
PUZ-M200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.48 | 3.61 | 3.40 | -20° | 19.00 | 15.50 | |
|
MXZ-2D42VA2/MSZ-SF20VA/MSZ-SF20VA
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 3.80 | 4.04 | -15° | 4.00 | 4.00 | |
|
PUZ-M200YDA/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.77 | 3.40 | -20° | 19.00 | 15.50 | |
|
PUZ-M250YDA/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.40 | 3.59 | 3.30 | -20° | 22.00 | 17.00 | |
|
PUZ-M250YKA2/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.39 | 3.56 | 3.30 | -20° | 22.00 | 20.20 | |
|
MXZ-6F120VF2/MSZ-AP60VG/MSZ-AP60VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 3.80 | 4.24 | -15° | 9.60 | 9.70 | |
|
MXZ-6F120VF3/MSZ-AP60VGK(P)2/MSZ-AP60VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 3.80 | 4.24 | -15° | 9.60 | 9.70 | |
|
PUZ-ZM250YKA2/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 3.57 | 3.40 | -20° | 22.00 | 20.20 | |
|
PUZ-ZM250YKA3/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 3.57 | 3.40 | -20° | 22.00 | 20.20 | |
|
PUZ-ZM200YKA3/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.61 | 3.50 | -20° | 19.00 | 18.90 | |
|
PUZ-ZM200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.62 | 3.50 | -20° | 19.00 | 18.90 |