Filters · 3 active
Manufacturer:
Fujitsu Atlantic
PANASONIC
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(40)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(140)
CIAT
(36)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(561)
EQUATION
(5)
FUJI ELECTRIC
(138)
FUJITSU
(332)
GENERAL
(210)
GREE
(122)
GSS
(4)
HAIER
(449)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(292)
MIDEA
(842)
MITSUBISHI ELECTRIC
(621)
Mitsubishi Heavy Industries
(219)
NORD
(52)
Nobu
(8)
RIELLO
(38)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(312)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG22KATA/ABYG22KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
AOYG24KATA/AUXG24KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
CU-3Z68TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.56 | -15° | 6.80 | 4.80 | |
|
CU-3TZ52TBE/CS-TZ25ZKEW/CS-TZ42ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.82 | -15° | 5.20 | 4.80 | |
|
CU-4Z68TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.56 | -15° | 6.80 | 4.80 | |
|
AOYG18KATA/ABYG18KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
CU-4Z80TBE/CS-Z35ZKEW/CS-TZ71ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.90 | 3.85 | -15° | 8.00 | 5.50 | |
|
U-140PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.78 | 3.71 | 3.70 | -15° | 14.00 | 13.60 | |
|
AOYG14KATA/ARXG14KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
U-140PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.71 | 3.70 | -15° | 14.00 | 13.60 | |
|
AOYG22KATA/ARXG22KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXG22KMLB
ARXG**K
|
Fujitsu Atlantic | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG18KATA/AUXG18KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOYG22KATA/AUXG22KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG18KATA/ARXG18KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOYG36KATA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG12KATA/ARXG12KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
U-125PZH4E5 / S-2545PK4E(3x)
2024
|
PANASONIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.79 | 3.71 | -20° | 12.20 | 9.50 | |
|
U-125PZH4E8 / S-2545PK4E(3x)
2024
|
PANASONIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.79 | 3.71 | -20° | 12.20 | 9.50 | |
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
CU-PZ25WKE / CS-PZ25WKE
2019
|
PANASONIC | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 4.09 | -15° | 2.50 | 1.90 | |
|
AOYG12KATA/AUXG12KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
CU-TZ42WKE / CS-TZ42WKEW
2019
|
PANASONIC | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -15° | 4.20 | 3.60 | |
|
CU-PZ35WKE / CS-PZ35WKE
2019
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.69 | -15° | 3.40 | 2.40 | |
|
AOYG07KPCA/ASYG07KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.97 | -15° | 2.00 | 2.20 | |
|
AOYG30KATA/ABYG30KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.50 | -15° | 8.50 | 8.00 | |
|
AOYG09KPCA/ASYG09KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
AOYG025KPCA/ASYG025KPCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.54 | -15° | 2.50 | 2.40 | |
|
U-200PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.07 | 3.87 | 3.71 | -20° | 16.00 | 15.70 | |
|
U-140PZH4E5 + P‐VTVF140MC5‐PE
2025
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E8 + P‐VTVF140MC5‐PE
2025
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
CU-UZ35WKE / CS-UZ35WKE
2019
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.70 | -15° | 3.30 | 2.40 | |
|
U-125PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.76 | 3.89 | -15° | 12.50 | 12.50 | |
|
CU-FZ60WKE / CS-FZ60WKE
2019
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.15 | -15° | 6.00 | 4.40 | |
|
CU-BZ60XKE / CS-BZ60XKE
2022
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.16 | -15° | 6.00 | 4.40 | |
|
AOYG24KBTB/AUXG24KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.69 | -15° | 6.80 | 6.00 | |
|
CU-UZ25WKE / CS-UZ25WKE
2019
|
PANASONIC | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 4.05 | -15° | 2.50 | 1.90 | |
|
AOYG14KATA/AUXG14KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
CU-UZ35ZKE / CS-UZ35ZKE
2023
|
PANASONIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.72 | -15° | 3.30 | 2.40 | |
|
U-125PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 3.76 | 3.89 | -15° | 12.50 | 12.50 | |
|
CU-TZ71WKE / CS-TZ71WKEW
2019
|
PANASONIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.51 | -15° | 7.10 | 5.50 | |
|
AOYG12KPCA/ASYG12KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOYG035KPCA/ASYG035KPCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOYG14KBTB/ARXG14KLLAP
ARY**K
|
Fujitsu Atlantic | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
CU-3Z52TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 4.02 | -15° | 5.20 | 5.00 | |
|
AOYG09KATA/AUXG09KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
CU-PZ50WKE / CS-PZ50WKE
2019
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.44 | -15° | 5.00 | 4.00 | |
|
AOYG24KATA/AUXG24KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.81 | -15° | 6.80 | 5.40 | |
|
CU-5Z90TBE/CS-Z35ZKEW/CS-TZ71ZKEW
2023
|
PANASONIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -15° | 9.00 | 6.50 |