Filters · 4 active
Manufacturer:
GSS
Rotenso
Vulcano
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(133)
CIAT
(38)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(845)
EQUATION
(5)
FUJI ELECTRIC
(165)
FUJITSU
(404)
Fujitsu Atlantic
(199)
GENERAL
(243)
GREE
(118)
HAIER
(549)
HEC
(5)
HEIWA
(8)
HISENSE
(341)
HITACHI
(138)
IVT
(10)
Inventor
(130)
KAYSUN
(52)
LG
(342)
MIDEA
(746)
MITSUBISHI ELECTRIC
(576)
Mitsubishi Heavy Industries
(223)
NORD
(56)
Nobu
(8)
PANASONIC
(272)
RIELLO
(41)
SAMSUNG
(206)
THERMOR
(58)
TOSHIBA
(291)
Viessmann
(24)
WESTPOINT
(22)
YORK
(33)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UE-EC 35 / UI-ECU M 35
Easy 3 Cool
|
Vulcano | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
GSX-IDU-009/GSX-ODU-009
GSX
|
GSS | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.75 | -10° | 2.50 | 2.45 | |
|
UE-EC 26 / UI-ECU M 26
Easy 3 Cool
|
Vulcano | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
UE-E3CM 82/4 / UI-L2CU M 26 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 3.80 | 3.40 | -10° | 8.20 | 6.00 | |
|
GSX-IDU-018/GSX-ODU-018
GSX
|
GSS | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.05 | 4.10 | |
|
UE-E3CM 53/2 / UI-L2CU M 26 + UI-L2CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
UE-EC 70 / UI-ECU M 70
Easy 3 Cool
|
Vulcano | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.05 | -10° | 7.00 | 4.80 | |
|
UE-E3CM 79/3 / UI-L2CU M 26 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 7.80 | 5.50 | |
|
UE-E3CM 62/2 / UI-L2CU M 26 + UI-L2CU M 35
Easy Cool M
|
Vulcano | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 6.10 | 5.70 | |
|
UE-E3CM 53/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
GSX-IDU-012/GSX-ODU-012
GSX
|
GSS | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.73 | -10° | 3.50 | 2.60 | |
|
GSX-IDU-024/GSX-ODU-024
GSX
|
GSS | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.71 | -10° | 6.95 | 5.20 | |
|
UE-E3CM 105/4 / UI-L2CU M 53 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
UE-E3CM 41/2 / UI-L2CU M 26 + UI-L2CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
T120Xi R16/UO120Xo R14
Tenji
|
Rotenso | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
UE-EC 53 / UI-ECU M 53
Easy 3 Cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
UE-L2C 26 / UI-L2CU M 26
Line cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
UE-L2C 70 / UI-L2CU M 70
Line cool
|
Vulcano | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
UE-L2C 35 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
UE-L2C 53 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N120Xi R15/UO120Xo R14
Nevo
|
Rotenso | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 |