Filters · 9 active
Manufacturer:
BOSCH
COLIBRI
Candy
Inventor
Rotenso
TOSHIBA
Vulcano
WESTPOINT
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(0)
AUX
(10)
BRYANT
(0)
Buderus
(2)
CARRIER
(22)
CIAT
(11)
CONFORT AIR
(0)
DAIKIN
(230)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(44)
FUJITSU
(133)
Fujitsu Atlantic
(69)
GENERAL
(69)
GREE
(6)
GSS
(0)
HAIER
(91)
HEC
(0)
HEIWA
(0)
HISENSE
(34)
HITACHI
(41)
IVT
(0)
KAYSUN
(26)
LG
(64)
MIDEA
(96)
MITSUBISHI ELECTRIC
(168)
Mitsubishi Heavy Industries
(100)
NORD
(10)
Nobu
(0)
PANASONIC
(42)
PITSOS
(0)
RIELLO
(11)
SAMSUNG
(23)
THERMOR
(5)
Viessmann
(7)
XTRON
(0)
YORK
(9)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GV1401AT8P-E+RAV-HM1401BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.00 | -15° | 12.10 | 7.80 | |
|
RAV-GV1101ATP-E/RAV-HM1101BTP-E
DIC
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.33 | -15° | 9.50 | 7.60 | |
|
RAV-GV1401ATP-E/RAV-HM1401BTP-E
DIC
|
TOSHIBA | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.05 | -15° | 11.50 | 7.80 | |
|
RAV-GV1101AT8P-E/RAV-HM1101BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.80 | 3.40 | -15° | 9.50 | 7.60 | |
|
CL5000M 53/2 E / CL5000iM D 26 E + CL5000iM D 26 E
Climate 5000 M
|
BOSCH | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 5.30 | 4.60 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.32 | 3.70 | 3.18 | -10° | 23.50 | 12.30 | |
|
RAV-GV561ATP-E/RAV-HM561BTP-E
DIC
|
TOSHIBA | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.90 | 3.21 | -15° | 5.00 | 2.80 | |
|
RAV-GM2803AT8P-E/RAV-RM2801DTP-E2
DI 3ph
|
TOSHIBA | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.70 | 3.15 | -10° | 22.50 | 12.30 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
RAV-GM1601ATP-E/RAV-HM1601BTP-E
DI
|
TOSHIBA | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.90 | 3.41 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601BTP-E
DI 3ph
|
TOSHIBA | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.90 | 3.41 | -15° | 14.00 | 8.00 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.80 | 3.32 | -10° | 20.00 | 11.40 | |
|
RAV-GV801ATP-E/RAV-HM801BTP-E
DIC
|
TOSHIBA | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 4.00 | 3.00 | -15° | 6.70 | 4.80 | |
|
RAV-GM1402AT8W-E/RAV-HM1401BTP-E
DI 3ph
|
TOSHIBA | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 3.84 | 3.71 | -15° | 12.10 | 8.40 | |
|
RAV-GM802ATW-E/RAV-HM801SDTY-E
DI
|
TOSHIBA | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 4.00 | 3.44 | -15° | 6.70 | 5.10 | |
|
U7RT-50/V7DI-50WiFiR
Ducted R32
|
Inventor | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
RAV-GM561ATP-E1/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.68 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
RAV-GM562ATP-E/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
RAV-GM1602AT8W-E/RAV-HM1601BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.96 | 3.43 | -15° | 14.00 | 8.40 | |
|
RAV-GM1102AT8W-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.92 | 3.90 | -15° | 9.50 | 8.40 | |
|
RAV-GM2243AT8P-E/RAV-RM2241DTP-E2
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 3.80 | 3.24 | -10° | 19.00 | 11.40 | |
|
RAV-GM561ATP-E1/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.39 | 4.08 | 3.27 | -15° | 5.00 | 2.80 | |
|
CL5000L 70 E / CL5000iU D 70 E
Climate 5000i U
|
BOSCH | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
U7RS-24/V7DI-24WiFiR
Ducted R32
|
Inventor | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
RAV-GM402ATP-E/RAV-HM401SDTY-E
DI
|
TOSHIBA | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.00 | 4.12 | -15° | 3.60 | 2.70 | |
|
RAV-GP1601AT8-E/RAV-HM1601BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.81 | 3.96 | 3.50 | -20° | 14.00 | 12.00 | |
|
RAV-GM1402ATW-E/RAV-HM1401BTP-E
DI
|
TOSHIBA | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 3.92 | 3.66 | -15° | 12.10 | 8.40 | |
|
RAV-GM801ATP-E/RAV-HM801BTP-E
DI
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.20 | 4.13 | 3.32 | -15° | 6.70 | 5.10 | |
|
RAV-GV1601ATP-E1/RAV-HM1601BTP-E
DIC 1ph
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 4.90 | 4.15 | 3.38 | -15° | 13.00 | 8.00 | |
|
RAV-GV1601AT8P-E1/RAV-HM1601BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 4.90 | 4.15 | 3.38 | -15° | 13.00 | 8.00 | |
|
U7iRT-50/V7iDI-50WiFiR
Ducted R32
|
Inventor | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
N140Xi R15/UO140Xo R15
Nevo
|
Rotenso | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
RAV-GP1401AT8-E1/RAV-HM1401BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.98 | 3.83 | -20° | 12.50 | 11.80 | |
|
CL5000L 105 E-3 / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
CL5001L 105 E-3 / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
CL5000L 35 E / CL5000iU D 35 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
U7RS-12/V7DI-12WiFiR
Ducted R32
|
Inventor | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
U7RS-42/V7DI-42WiFiR
Ducted R32
|
Inventor | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -10° | 12.10 | 9.50 | |
|
N120Xi R15/UO120Xo R14
Nevo
|
Rotenso | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
CL5000L 105 E / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
U7RS-36/V7DI-36WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
CL5000L 53 E / CL5000iU D 53 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
U7RS-18/V7DI-18WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 5.40 | 4.30 | |
|
U7RS-42/V7iDI-42WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
RAV-GM1101ATP-E/RAV-HM1101BTP-E
DI
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.28 | 4.19 | 3.75 | -15° | 9.50 | 7.60 | |
|
RAV-GM1101AT8P-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.28 | 4.19 | 3.75 | -15° | 9.50 | 7.60 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401BTP-E
DI 3ph
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.36 | 4.19 | 3.61 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401BTP-E
DI
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.36 | 4.19 | 3.61 | -15° | 12.10 | 7.60 | |
|
U7RT-60/V7DI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
U7iRT-60/V7iDI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 |