Filters · 5 active
Manufacturer:
BOSCH
Candy
Rotenso
Viessmann
Vulcano
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(145)
BRYANT
(6)
Buderus
(38)
CARRIER
(159)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
DAIKIN
(882)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(139)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(409)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(74)
LG
(358)
MIDEA
(843)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
PITSOS
(6)
RIELLO
(47)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
WESTPOINT
(24)
XTRON
(4)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UE-E3CM 41/2 / UI-E3CU M 26 + UI-E3CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
CL5000L 105 E-3 / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
T140Xi R16/UO140Xo R15
Tenji
|
Rotenso | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
T160Xi R16/UO160Xo R15
Tenji
|
Rotenso | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
Vitoclima 050-S IWAA050MFA026/Vitoclima 050-S OWAA050MFA026
Wall mounted
|
Viessmann | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
T120Xi R16/UO120Xo R14
Tenji
|
Rotenso | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
UE-EC 53 / UI-ECU M 53
Easy 3 Cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL3000i 70 E / CL3000iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 70 E / CL3200iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24DW31/ASI24DW31
Series 4
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24AW31/ASI24AW31
Series 6
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
UE-L2C 70 / UI-L2CU M 70
Line cool
|
Vulcano | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 26 E / CL3000iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
CL3000i 26 E / CL3200iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
ASO09DW31/ASI09DW31
Series 4
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
UE-L2C 26 / UI-L2CU M 26
Line cool
|
Vulcano | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
CL5000L 105 E-3 / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
CL5000M 53/2 E / CL5000iM CN 26E + CL5000iM CN 26E
Climate 5000 M
|
BOSCH | Console | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
Vitoclima 050-S IWAA050MFA052/Vitoclima 050-S OWAA050MFA052
Wall mounted
|
Viessmann | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.00 | 3.31 | -10° | 5.20 | 4.10 | |
|
CL3000i 35 E / CL3000iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
CL3000i 35 E / CL3200iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
ASO12DW31/ASI12DW31
Series 4
|
BOSCH | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
UE-L2C 35 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
CL5001L 70 E / CL5000iU 4C 70 E
Climate 5001 L
|
BOSCH | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
Vitoclima100-SIC8AA100MFA070/Vitoclima100-SPROOFAA100MFP070
Cassette
|
Viessmann | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
Vitoclima100-SIFCAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ceiling suspended
|
Viessmann | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
Vitoclima100-SPROIC8AA100MFP105/Vitoclima100-SPROOFAA100TFP105
Cassette
|
Viessmann | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
ASO18DW31/ASI18DW31
Series 4
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
ASO18AW31/ASI18AW31
Series 6
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
UE-L2C 53 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL5000L 53 E / CL5000iL CF 53 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
J160Xi R14/UO160Xo R15
Jato
|
Rotenso | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
J140Xi R14/UO140Xo R15
Jato
|
Rotenso | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
CL5001L 53 E / CL5001iU 4CC 53 E
Climate 5001 L
|
BOSCH | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
Vitoclima100-SIC8AA100MFA052/Vitoclima100-SPROOFAA100MFP052
Cassette
|
Viessmann | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 3.57 | -10° | 5.30 | 4.20 | |
|
CL5000L 70 E / CL5000iU D 70 E
Climate 5000i U
|
BOSCH | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.10 | 5.40 | |
|
Vitoclima100-SPROIFCAA100MFP105/Vitoclima100-SPROOFAA100TFP105
Ceiling suspended
|
Viessmann | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
CL5000L 105 E / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
Vitoclima100-SPROIC8AA100MFP105/Vitoclima100-SPROOFAA100MFP105
Cassette
|
Viessmann | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
CL5000L 35 E / CL5000iU 4CC 35 E
Climate 5000i L
|
BOSCH | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
N140Xi R15/UO140Xo R15
Nevo
|
Rotenso | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
CL6102i 55 HE / CL6102i W 55 HE
Climate 6102i
|
BOSCH | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.10 | 3.40 | -10° | 5.30 | 4.40 | |
|
CL5000L 105 E-3 / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 |