Filters · 3 active
Manufacturer:
FUJITSU
THERMOR
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(40)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(130)
CIAT
(36)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(560)
EQUATION
(5)
FUJI ELECTRIC
(138)
Fujitsu Atlantic
(165)
GENERAL
(210)
GREE
(122)
GSS
(4)
HAIER
(449)
HEC
(5)
HEIWA
(8)
HISENSE
(314)
HITACHI
(148)
IVT
(10)
Inventor
(124)
KAYSUN
(47)
LG
(292)
MIDEA
(728)
MITSUBISHI ELECTRIC
(472)
Mitsubishi Heavy Industries
(219)
NORD
(52)
Nobu
(8)
PANASONIC
(254)
RIELLO
(38)
Rotenso
(0)
SAMSUNG
(191)
TOSHIBA
(252)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(31)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
IM26-NS + IM26-NS/E3U55LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.00 | -10° | 4.60 | 3.80 | |
|
IM35-NS + IM35-NS/E3U70LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 2.90 | -10° | 6.20 | 4.80 | |
|
IM26V2-NG + IM26V2-NG/E3U55LV2-NG-NS
MULTI -NAGANO MURALE PURE
|
THERMOR | Wall mounted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.10 | -10° | 4.80 | 4.00 | |
|
IM52-NS + IM35-NS/E4U85LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 2.90 | -10° | 7.30 | 6.30 | |
|
NAGANO CASSETTE IK26-F66-NG/E1U26LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
NAGANO CASSETTE IK35-F66-NG / E1U35LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 3.00 | |
|
IM35V2-NG + IM35V2-NG/E3U70LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.00 | -10° | 6.40 | 5.00 | |
|
NISEKO COMPACT IM20-NSC/E1U20L-NSC
NISEKO COMPACT
|
THERMOR | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.30 | -10° | 2.60 | 1.90 | |
|
IM52-NS + IM70-NS/E5U10LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.00 | -10° | 8.20 | 7.30 | |
|
NISEKO MURALE IM35-NS / E1U35L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.50 | 2.80 | |
|
NAGANO UI CASSETTE 600 x 600 5000W R32 / NAGANO U.E MONO 5200W R32
NAGANO CASSETTE
|
THERMOR | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.42 | -10° | 5.00 | 4.00 | |
|
NISEKO MURALE IM20-NS / E1U20L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 2.40 | |
|
NISEKO MURALE IM26-NS / E1U26L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 2.40 | |
|
IM52V2-NG + IM35V2-NG/E4U85LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.00 | -10° | 7.50 | 6.50 | |
|
AOYG22KATA/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ABEG22KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ABYG22KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.35 | -15° | 6.00 | 4.40 | |
|
NAGANO U.I 2600W R32+NAGANO U.I 3500W R32/NAGANO U.E BI 4000W R32
NAGANO MURALE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
IM26V2-NG + IM35V2-NG/NAGANO U.E BI 4000W R32
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
AOYG24KATA/AUXG24KVLA
AUXG**K
|
FUJITSU | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
AOEG24KATA/AUXG24KVLA
AUXG**K
|
FUJITSU | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.61 | -15° | 6.80 | 5.40 | |
|
IM52V2-NG + IM70V2-NG/E5U10LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
AOYG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABEG18KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ABYG18KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOYG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
NISEKO MURALE IM42-NS / E1U42L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
NISEKO MURALE IM52-NS / E1U52L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.60 | |
|
AOYG22KATA/ARXG22KMLA
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/ARXG22KMLB
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/ARXG22KMLB
ARXG**K
|
FUJITSU | Ducted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG18KATA/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.49 | -15° | 5.20 | 3.80 | |
|
AOYG22KATA/AUXG22KVLA
AUXG**K
|
FUJITSU | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/AUXG22KVLA
AUXG**K
|
FUJITSU | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.50 | -15° | 6.00 | 4.40 | |
|
AOYG18KATA/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/ARXG18KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.51 | -15° | 5.20 | 3.80 | |
|
AOYG36KATA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/ABEG36KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KQTA/ABEG36KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KQTA/ABYG36KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG12KATA/ARXG12KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOEG12KATA/ARXG12KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOEG09KATA/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
NAGANO GAINABLE MP IG71MP-NG / E1U70LV2-NG
NAGANO GAINABLE MOYENNE PRESSION
|
THERMOR | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 7.10 | 5.00 | |
|
NAGANO CASSETTE IK70-F88-NG / E1U70LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.72 | -10° | 7.10 | 5.00 |