Filters · 3 active
Manufacturer:
PANASONIC
THERMOR
AIRCLASS
(0)
AIRWELL
(8)
ATLANTIC
(4)
AUX
(42)
BOSCH
(19)
BRYANT
(0)
Buderus
(12)
CARRIER
(29)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(3)
DAIKIN
(214)
EQUATION
(1)
FUJI ELECTRIC
(7)
FUJITSU
(23)
Fujitsu Atlantic
(8)
GENERAL
(16)
GREE
(9)
GSS
(0)
HAIER
(140)
HEC
(2)
HEIWA
(0)
HISENSE
(0)
HITACHI
(38)
IVT
(0)
Inventor
(9)
KAYSUN
(0)
LG
(8)
MIDEA
(70)
MITSUBISHI ELECTRIC
(120)
Mitsubishi Heavy Industries
(152)
NORD
(11)
Nobu
(0)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(16)
TOSHIBA
(53)
Viessmann
(0)
Vulcano
(8)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
IM26-NS + IM26-NS/E3U55LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.00 | -10° | 4.60 | 3.80 | |
|
IM35-NS + IM35-NS/E3U70LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 2.90 | -10° | 6.20 | 4.80 | |
|
IM26V2-NG + IM26V2-NG/E3U55LV2-NG-NS
MULTI -NAGANO MURALE PURE
|
THERMOR | Wall mounted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.10 | -10° | 4.80 | 4.00 | |
|
IM52-NS + IM35-NS/E4U85LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 2.90 | -10° | 7.30 | 6.30 | |
|
IM35V2-NG + IM35V2-NG/E3U70LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.00 | -10° | 6.40 | 5.00 | |
|
IM52-NS + IM70-NS/E5U10LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.00 | -10° | 8.20 | 7.30 | |
|
IM52V2-NG + IM35V2-NG/E4U85LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.00 | -10° | 7.50 | 6.50 | |
|
NAGANO U.I 2600W R32+NAGANO U.I 3500W R32/NAGANO U.E BI 4000W R32
NAGANO MURALE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
IM26V2-NG + IM35V2-NG/NAGANO U.E BI 4000W R32
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
IM52V2-NG + IM70V2-NG/E5U10LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
CU-3Z68TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.56 | -15° | 6.80 | 4.80 | |
|
CU-3TZ52TBE/CS-TZ25ZKEW/CS-TZ42ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.82 | -15° | 5.20 | 4.80 | |
|
CU-4Z68TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.56 | -15° | 6.80 | 4.80 | |
|
CU-4Z80TBE/CS-Z35ZKEW/CS-TZ71ZKEW
2023
|
PANASONIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.90 | 3.85 | -15° | 8.00 | 5.50 | |
|
IM35V2-NG + IM35V2-NG/E2U50LV2-NG-NS
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 5.00 | 4.70 | |
|
U-200PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.07 | 3.87 | 3.71 | -20° | 16.00 | 15.70 | |
|
CU-3Z52TBE/CS-Z35ZKEW/CS-Z35ZKEW
2023
|
PANASONIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 4.02 | -15° | 5.20 | 5.00 | |
|
CU-5Z90TBE/CS-Z35ZKEW/CS-TZ71ZKEW
2023
|
PANASONIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -15° | 9.00 | 6.50 | |
|
U-140PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
U-140PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
CU-3TZ52CBE/CS-TZ42CKEW/CS-TZ42CKEW
2025
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.60 | -15° | 5.20 | 4.80 | |
|
U-100PZ3E5/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZ3E8/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-125PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
U-125PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
CU-5Z90CBE/CS-Z71CKEW/CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 4.43 | -15° | 9.00 | 8.50 | |
|
CU-2TZ41TBE/CS-TZ25ZKEW/CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 4.49 | -15° | 4.10 | 3.50 | |
|
CU-2Z35TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 5.00 | -15° | 3.50 | 3.20 | |
|
CU-4Z80CBE/CS-Z71CKEW/CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.33 | -15° | 8.00 | 6.80 | |
|
CU-3Z52CBE / CS-Z42CKEW / CS-Z42CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 4.12 | -15° | 5.20 | 5.20 | |
|
CU-2TZ50TBE/CS-TZ25ZKEW/CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.35 | -15° | 5.00 | 4.50 | |
|
U-250PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 3.75 | 3.55 | -20° | 22.00 | 17.20 | |
|
CU-2Z41TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.84 | -15° | 4.10 | 3.50 | |
|
CU-2TZ41CBE/CS-MTZ16CKE/CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.20 | 4.07 | -15° | 4.10 | 3.50 | |
|
U-200PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 3.83 | 3.55 | -20° | 19.00 | 16.00 | |
|
CU-3Z68CBE / CS-Z50CKEW / CS-Z50CKEW
2025
|
PANASONIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.15 | -15° | 6.80 | 5.20 | |
|
CU-4Z68CBE / CS-Z50CKEW / CS-Z50CKEW
2025
|
PANASONIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 4.15 | -15° | 6.80 | 5.20 | |
|
CU-2TZ50CBE/CS-TZ25CKEW/CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.20 | 3.97 | -15° | 5.00 | 4.20 | |
|
CU-2Z50TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.63 | -15° | 5.00 | 4.20 | |
|
U-100PZH4E5/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-100PZH4E8/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.89 | -20° | 9.50 | 8.00 | |
|
U-71PZH4E5/S-2545PK4E/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-71PZH4E8/S-2545PK4E/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 4.00 | -20° | 7.10 | 5.20 | |
|
U-140PZH4E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.31 | 3.71 | -20° | 13.40 | 10.60 | |
|
U-140PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.31 | 3.71 | -20° | 13.40 | 10.60 | |
|
CU-3Z75ABEC/CS-Z50CKEW/CS-Z50CKEW
2025
|
PANASONIC | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 4.32 | -25° | 7.50 | 5.60 | |
|
U-125PZH4E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
U-125PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.88 | 4.32 | 4.09 | -20° | 12.50 | 9.50 | |
|
CU-2Z50ABEC/CS-Z25CKEW/CS-Z25CKEW
2025
|
PANASONIC | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.40 | 4.18 | -25° | 5.30 | 5.10 | |
|
CU-3Z75ABEC/CS-HZ35ZKE/CS-HZ35ZKE
2024
|
PANASONIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.34 | -25° | 7.00 | 5.70 |