Filters · 3 active
Manufacturer:
TOSHIBA
AIRCLASS
(0)
AIRWELL
(21)
ATLANTIC
(0)
AUX
(14)
BOSCH
(21)
BRYANT
(0)
Buderus
(3)
CARRIER
(24)
CIAT
(13)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(230)
EQUATION
(0)
FUJI ELECTRIC
(44)
FUJITSU
(133)
Fujitsu Atlantic
(69)
GENERAL
(69)
GREE
(6)
GSS
(0)
HAIER
(99)
HEC
(0)
HEIWA
(0)
HISENSE
(40)
HITACHI
(41)
IVT
(2)
Inventor
(18)
KAYSUN
(29)
LG
(67)
MIDEA
(119)
MITSUBISHI ELECTRIC
(168)
Mitsubishi Heavy Industries
(100)
NORD
(13)
Nobu
(0)
PANASONIC
(50)
RIELLO
(13)
Rotenso
(3)
SAMSUNG
(23)
THERMOR
(8)
Viessmann
(9)
Vulcano
(0)
WESTPOINT
(0)
YORK
(9)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GV1401AT8P-E+RAV-HM1401BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.00 | -15° | 12.10 | 7.80 | |
|
RAV-GV1101ATP-E/RAV-HM1101BTP-E
DIC
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.33 | -15° | 9.50 | 7.60 | |
|
RAV-GV1401ATP-E/RAV-HM1401BTP-E
DIC
|
TOSHIBA | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.05 | -15° | 11.50 | 7.80 | |
|
RAV-GV1101AT8P-E/RAV-HM1101BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.80 | 3.40 | -15° | 9.50 | 7.60 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.32 | 3.70 | 3.18 | -10° | 23.50 | 12.30 | |
|
RAV-GV561ATP-E/RAV-HM561BTP-E
DIC
|
TOSHIBA | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.90 | 3.21 | -15° | 5.00 | 2.80 | |
|
RAV-GM2803AT8P-E/RAV-RM2801DTP-E2
DI 3ph
|
TOSHIBA | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.70 | 3.15 | -10° | 22.50 | 12.30 | |
|
RAV-GM1601ATP-E/RAV-HM1601BTP-E
DI
|
TOSHIBA | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.90 | 3.41 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601BTP-E
DI 3ph
|
TOSHIBA | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.90 | 3.41 | -15° | 14.00 | 8.00 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.80 | 3.32 | -10° | 20.00 | 11.40 | |
|
RAV-GV801ATP-E/RAV-HM801BTP-E
DIC
|
TOSHIBA | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 4.00 | 3.00 | -15° | 6.70 | 4.80 | |
|
RAV-GM1402AT8W-E/RAV-HM1401BTP-E
DI 3ph
|
TOSHIBA | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 3.84 | 3.71 | -15° | 12.10 | 8.40 | |
|
RAV-GM802ATW-E/RAV-HM801SDTY-E
DI
|
TOSHIBA | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 4.00 | 3.44 | -15° | 6.70 | 5.10 | |
|
RAV-GM561ATP-E1/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.68 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
RAV-GM562ATP-E/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
RAV-GM1602AT8W-E/RAV-HM1601BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.96 | 3.43 | -15° | 14.00 | 8.40 | |
|
RAV-GM1102AT8W-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.92 | 3.90 | -15° | 9.50 | 8.40 | |
|
RAV-GM2243AT8P-E/RAV-RM2241DTP-E2
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 3.80 | 3.24 | -10° | 19.00 | 11.40 | |
|
RAV-GM561ATP-E1/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.39 | 4.08 | 3.27 | -15° | 5.00 | 2.80 | |
|
RAV-GM402ATP-E/RAV-HM401SDTY-E
DI
|
TOSHIBA | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.00 | 4.12 | -15° | 3.60 | 2.70 | |
|
RAV-GP1601AT8-E/RAV-HM1601BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.81 | 3.96 | 3.50 | -20° | 14.00 | 12.00 | |
|
RAV-GM1402ATW-E/RAV-HM1401BTP-E
DI
|
TOSHIBA | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 3.92 | 3.66 | -15° | 12.10 | 8.40 | |
|
RAV-GM801ATP-E/RAV-HM801BTP-E
DI
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.20 | 4.13 | 3.32 | -15° | 6.70 | 5.10 | |
|
RAV-GV1601ATP-E1/RAV-HM1601BTP-E
DIC 1ph
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 4.90 | 4.15 | 3.38 | -15° | 13.00 | 8.00 | |
|
RAV-GV1601AT8P-E1/RAV-HM1601BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 4.90 | 4.15 | 3.38 | -15° | 13.00 | 8.00 | |
|
RAV-GP1401AT8-E1/RAV-HM1401BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.98 | 3.83 | -20° | 12.50 | 11.80 | |
|
RAV-GM1101ATP-E/RAV-HM1101BTP-E
DI
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.28 | 4.19 | 3.75 | -15° | 9.50 | 7.60 | |
|
RAV-GM1101AT8P-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.28 | 4.19 | 3.75 | -15° | 9.50 | 7.60 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401BTP-E
DI 3ph
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.36 | 4.19 | 3.61 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401BTP-E
DI
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.36 | 4.19 | 3.61 | -15° | 12.10 | 7.60 | |
|
RAV-GM1602ATW-E/RAV-HM1601BTP-E
DI
|
TOSHIBA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.05 | 3.38 | -15° | 14.00 | 8.40 | |
|
RAV-GM562ATP-E/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.11 | 3.27 | -15° | 5.00 | 2.80 | |
|
RAV-GM1102ATW-E/RAV-HM1101BTP-E
DI
|
TOSHIBA | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.85 | -15° | 9.50 | 8.40 | |
|
RAV-GM302ATP-E/RAV-HM301SDTY-E
DI
|
TOSHIBA | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.21 | 3.95 | -15° | 2.50 | 2.60 | |
|
RAV-GP561ATW-E/RAV-HM561BTP-E
SDI
|
TOSHIBA | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.81 | 4.27 | 3.48 | -27° | 5.00 | 3.80 | |
|
RAV-GP1101AT8-E/RAV-HM1101BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.19 | 4.06 | -20° | 10.00 | 10.80 | |
|
RAV-GM901ATP-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
RAV-GM802ATW-E/RAV-HM801BTP-E
DI
|
TOSHIBA | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.37 | 4.30 | 3.77 | -15° | 6.70 | 5.10 | |
|
RAV-GP561ATW-E/RAV-HM561SDTY-E
SDI
|
TOSHIBA | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.23 | 3.56 | -27° | 5.00 | 3.80 | |
|
RAV-GM902ATW-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.75 | 4.30 | 4.00 | -15° | 8.00 | 6.30 | |
|
RAV-GP561ATW-E/RAV-HM561MUTP-E
SDI
|
TOSHIBA | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.27 | 4.32 | 3.50 | -27° | 5.00 | 3.80 | |
|
RAV-GP1401AT-E1/RAV-HM1401BTP-E
SDI
|
TOSHIBA | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.28 | 3.86 | -27° | 12.50 | 9.60 | |
|
RAV-GP801ATW-E/RAV-HM801SDTY-E
SDI
|
TOSHIBA | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.27 | 3.77 | -27° | 7.10 | 5.10 | |
|
RAV-GP1101AT-E/RAV-HM1101BTP-E
SDI
|
TOSHIBA | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.19 | 4.30 | 4.10 | -27° | 10.00 | 9.20 | |
|
RAV-GP801ATW-E/RAV-HM801BTP-E
SDI
|
TOSHIBA | Ducted | 99 ★ best in class Score ≥ 99 — top of its capacity class. Why? | 7.86 | 4.85 | 4.32 | -27° | 7.10 | 5.10 |