Filters · 5 active
Manufacturer:
BOSCH
Candy
LG
SAMSUNG
WESTPOINT
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(145)
BRYANT
(6)
Buderus
(38)
CARRIER
(159)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
DAIKIN
(882)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(139)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(409)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(74)
MIDEA
(843)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
PITSOS
(6)
RIELLO
(47)
Rotenso
(8)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
XTRON
(4)
YORK
(39)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UUD3 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD1 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
AC120RXADKG/AC120RN4DKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.18 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RN4DKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
AC120RXADKG/AC120RN4PKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RN4PKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
CL5000L 53 E / CL5000iU 4CC 53 E
Climate 5000i L
|
BOSCH | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.48 | -10° | 5.30 | 4.20 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
UUB1 U20 / CL18F N60
UU
|
LG | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.28 | -10° | 5.00 | 4.10 | |
|
AC071RXADKG/AC071TNXDKG
CAC
|
SAMSUNG | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.40 | -20° | 7.10 | 3.60 | |
|
AC035RXADKG/AC035RNJDKG
CAC
|
SAMSUNG | Floor standing | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.07 | -20° | 3.50 | 2.00 | |
|
WIMO-09225.MH / WIM-09225.MH
WIM 225
|
WESTPOINT | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
AJ050TXJ2KH / AJ025TNAPKH / AJ025TNAPKH
FJM
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.01 | 3.68 | -10° | 5.00 | 4.21 | |
|
UUD1 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD1 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUC1 U40 / CM24F NA0
U4
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.31 | -10° | 6.80 | 5.40 | |
|
UUA1 UL0 / UM12FH N10
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 4.10 | -10° | 3.50 | 2.80 | |
|
UUA1 UL0 / UM12FH NA0
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 4.10 | -10° | 3.50 | 2.80 | |
|
AR18BXHQASIN / AR18BXHQASIX
RAC
|
SAMSUNG | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -10° | 5.30 | 4.20 | |
|
AR12TXFZBWKN/AR12TXFZBWKX
RAC
|
SAMSUNG | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.30 | 3.64 | -11° | 3.50 | 2.40 | |
|
UUC1 U40 / UM36F N20
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
UUC1 U40 / UM36F N21
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
AR09TXFZBWKN/AR09TXFZBWKX
RAC
|
SAMSUNG | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.30 | 3.95 | -11° | 2.50 | 2.30 | |
|
CL2000 53 E / CL2000U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
CL2001 53 E / CL2001U W 53 E
Climate 2000
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.60 | -10° | 5.20 | 4.10 | |
|
APUW48GT3EA / APNW48GT3EA
UU
|
LG | Floor standing | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.41 | -10° | 13.40 | 11.00 | |
|
W24TI UEU / W24TI NEU
24TI
|
LG | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -15° | 7.00 | 5.20 | |
|
CL3000i 70 E / CL3000iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
CL3000i 70 E / CL3200iU W 70 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24DW31/ASI24DW31
Series 4
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
ASO24AW31/ASI24AW31
Series 6
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
WIMO-24222.MH / WIM-24222.MH
WIM 222
|
WESTPOINT | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.38 | -25° | 7.00 | 4.90 | |
|
AC035RXADKG/AC035RN1DKG
CAC
|
SAMSUNG | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.12 | -20° | 3.50 | 2.00 | |
|
CL3000i 26 E / CL3000iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
CL3000i 26 E / CL3200iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
ASO09DW31/ASI09DW31
Series 4
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
CL5000L 105 E-3 / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
AC035RXADKG/AC035BNLDKG
CAC
|
SAMSUNG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.31 | -20° | 3.50 | 2.00 | |
|
CL5000M 53/2 E / CL5000iM CN 26E + CL5000iM CN 26E
Climate 5000 M
|
BOSCH | Console | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 3.71 | -10° | 5.30 | 4.50 | |
|
UUC1 U40 / CL24F N30
U4
|
LG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 3.90 | 3.52 | -10° | 6.80 | 5.40 | |
|
MU4R27 U42 / MJ09PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.70 | 3.80 | 3.60 | -10° | 6.80 | 6.70 | |
|
MU5R30 U42 / MJ12PC NSJ0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 3.80 | 3.40 | -10° | 7.30 | 6.90 | |
|
CL3000i 35 E / CL3000iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
CL3000i 35 E / CL3200iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
ASO12DW31/ASI12DW31
Series 4
|
BOSCH | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
UUB1 U20 / US30F NR0
UU
|
LG | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.60 | -10° | 7.50 | 4.30 |