Filters · 3 active
Manufacturer:
PANASONIC
WESTPOINT
AIRCLASS
(4)
AIRWELL
(18)
ATLANTIC
(22)
AUX
(4)
BOSCH
(57)
BRYANT
(0)
Buderus
(20)
CARRIER
(31)
CIAT
(4)
COLIBRI
(2)
CONFORT AIR
(2)
Candy
(2)
DAIKIN
(255)
EQUATION
(2)
FUJI ELECTRIC
(21)
FUJITSU
(58)
Fujitsu Atlantic
(28)
GENERAL
(54)
GREE
(32)
GSS
(0)
HAIER
(141)
HEC
(0)
HEIWA
(4)
HISENSE
(82)
HITACHI
(30)
IVT
(9)
Inventor
(40)
KAYSUN
(6)
LG
(30)
MIDEA
(197)
MITSUBISHI ELECTRIC
(76)
Mitsubishi Heavy Industries
(69)
NORD
(16)
Nobu
(0)
RIELLO
(4)
Rotenso
(0)
SAMSUNG
(47)
THERMOR
(16)
TOSHIBA
(50)
Viessmann
(0)
Vulcano
(0)
YORK
(2)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
WIM-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
CU-2Z35TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 5.00 | -15° | 3.50 | 3.20 | |
|
CU-2Z41TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.84 | -15° | 4.10 | 3.50 | |
|
CU-2TZ41CBE/CS-MTZ16CKE/CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.20 | 4.07 | -15° | 4.10 | 3.50 | |
|
WITO-12322.MH/WIT-12322.MH
WIT
|
WESTPOINT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -10° | 3.50 | 2.60 | |
|
WIMO-12325.MH / WIM-12325.MH
WIM 325
|
WESTPOINT | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
CU-2Z50TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.63 | -15° | 5.00 | 4.20 | |
|
WIMO-24322.MH/WIM-24322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WITO-24322.MH/WIT-24322.MH
WIT
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WIMO-24326.MH / WIM-24326.MH
WIM 326
|
WESTPOINT | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.71 | -10° | 7.00 | 5.00 | |
|
WIMO-18322.MH/WIM-18322.MH
NEW GENERATION A+++
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WITO-18322.MH/WIT-18322.MH
WIT
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 3.71 | -10° | 5.30 | 4.30 | |
|
WIMO-18324.MH / WIM-18324.MH
WIM 324
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
WIMO-18326.MH / WIM-18326.MH
WIM 326
|
WESTPOINT | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.72 | -10° | 5.00 | 3.40 | |
|
WIMO-09325.MH / WIM-09325.MH
WIM 325
|
WESTPOINT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.30 | -10° | 2.60 | 2.50 | |
|
WIMO-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -10° | 2.60 | 2.40 | |
|
WIM-12323.MH
WIM 323
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIMO-12323.MH
WIM 323
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WIMO-12326.MH / WIM-12326.MH
WIM 326
|
WESTPOINT | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.90 | -25° | 3.50 | 2.60 | |
|
WITO-09322.MH/WIT-09322.MH
WIT
|
WESTPOINT | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.51 | -25° | 2.80 | 2.40 | |
|
WIMO-18325.MH / WIM-18325.MH
WIM 325
|
WESTPOINT | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 5.00 | 4.00 | |
|
CU-Z42YKEA / CS-Z42YKEA
2022
|
PANASONIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 3.93 | -15° | 4.20 | 3.60 | |
|
CU-Z42YKEA-1 / CS-Z42YKEA-1
2024
|
PANASONIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 3.93 | -15° | 4.20 | 3.60 | |
|
CU-Z20XKE / CS-Z20XKEW
2021
|
PANASONIC | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.80 | 4.52 | -15° | 2.10 | 2.10 | |
|
CU-Z20XKE / CS-XZ20XKEW
2021
|
PANASONIC | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.80 | 4.52 | -15° | 2.10 | 2.10 | |
|
CU-NZ25YKE / CS-NZ25YKE
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
CU-NZ25YKE / CS-NZ25YKE-1
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
WIMO-24325.MH / WIM-24325.MH
WIM 325
|
WESTPOINT | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 6.10 | 4.80 | |
|
CU-2Z50ABEC/CS-Z25CKEW/CS-Z25CKEW
2025
|
PANASONIC | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.40 | 4.18 | -25° | 5.30 | 5.10 | |
|
CU-Z25YKEA / CS-Z25YKEA
2022
|
PANASONIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.50 | 4.60 | 4.86 | -15° | 2.50 | 2.70 | |
|
CU-Z25YKEA-1 / CS-Z25YKEA-1
2024
|
PANASONIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.50 | 4.60 | 4.86 | -15° | 2.50 | 2.70 | |
|
WIMO-09326.MH / WIM-09326.MH
WIM 326
|
WESTPOINT | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 4.50 | -25° | 2.60 | 2.40 | |
|
CU-Z35YKEA / CS-Z35YKEA
2022
|
PANASONIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.60 | 4.60 | 4.44 | -15° | 3.50 | 3.20 | |
|
CU-Z35YKEA-1 / CS-Z35YKEA-1
2024
|
PANASONIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.60 | 4.60 | 4.44 | -15° | 3.50 | 3.20 | |
|
U-50PZH3E5/S-2545PK4E/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 4.03 | -20° | 5.00 | 4.50 | |
|
U-50PZH3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.60 | 4.03 | -20° | 5.00 | 4.50 | |
|
CU-Z50YKEA / CS-Z50YKEA
2022
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 4.08 | -15° | 4.70 | 4.20 | |
|
CU-Z50YKEA-1 / CS-Z50YKEA-1
2024
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 4.08 | -15° | 5.00 | 4.20 | |
|
CU-Z20ZKE / CS-Z20ZKEW
2023
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
CU-Z20ZKE / CS-XZ20ZKEW
2023
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
CU-Z20ZKE / CS-XZ20ZKEW-H
2023
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
CU-Z20CKE / CS-Z20CKEW
2025
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
CU-Z20CKE / CS-XZ20CKEW
2025
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
CU-Z20CKE / CS-XZ20CKEW-H
2025
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.80 | 4.67 | -20° | 2.10 | 2.40 | |
|
U-36PZH3E5 / S-3650PK3E
2021
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.40 | 4.90 | 4.82 | -20° | 3.60 | 3.60 | |
|
CU-2Z50CBE / CS-Z25CKEW / CS-Z25CKEW
2025
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 4.63 | -15° | 5.00 | 4.20 | |
|
CU-NZ35YKE / CS-NZ35YKE
2023
|
PANASONIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 5.00 | 4.65 | -25° | 3.50 | 3.60 | |
|
CU-NZ35YKE / CS-NZ35YKE-1
2024
|
PANASONIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 5.00 | 4.65 | -25° | 3.50 | 3.60 | |
|
CU-2Z50ABEC/CS-HZ25ZKE/CS-HZ25ZKE
2024
|
PANASONIC | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 4.60 | 4.71 | -25° | 5.30 | 5.20 | |
|
CU-Z35CBEA / CS-Z35CFEAW
2025
|
PANASONIC | Console | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 4.60 | 3.98 | -15° | 3.50 | 3.20 |