Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(77)
ATLANTIC
(40)
AUX
(135)
BOSCH
(127)
BRYANT
(6)
Buderus
(37)
CARRIER
(132)
CIAT
(30)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(560)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(138)
FUJITSU
(332)
Fujitsu Atlantic
(165)
GENERAL
(210)
GREE
(131)
GSS
(4)
HAIER
(439)
HEC
(5)
HEIWA
(8)
HISENSE
(380)
HITACHI
(130)
IVT
(10)
Inventor
(117)
KAYSUN
(42)
LG
(290)
MIDEA
(680)
MITSUBISHI ELECTRIC
(476)
Mitsubishi Heavy Industries
(219)
NORD
(52)
Nobu
(8)
PANASONIC
(254)
PITSOS
(6)
RIELLO
(32)
Rotenso
(0)
SAMSUNG
(182)
THERMOR
(58)
TOSHIBA
(253)
Viessmann
(18)
Vulcano
(15)
WESTPOINT
(24)
XTRON
(4)
YORK
(25)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AR70H09CACBN/AR70H09CACBX
RAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
CU-TZ71CKEW / CS-TZ71CKEW
2025
|
PANASONIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.71 | -15° | 7.10 | 5.50 | |
|
AB71S2SA1FA(H)/1U71S2SR3FA
1-way cassette-Monosplit
|
HAIER | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.72 | -10° | 6.90 | 5.00 | |
|
AB71S2SR1FA(H)/1U71S2SR2FA
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.72 | -10° | 7.10 | 5.00 | |
|
RPIL-1.5UNE1NH / RAS-1.5UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.82 | -15° | 3.52 | 3.52 | |
|
U-36PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 4.15 | -15° | 3.40 | 2.40 | |
|
AOYG22KATA/AUXG22KRLB
AUXG**K
|
FUJITSU | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.63 | -15° | 6.00 | 4.40 | |
|
ROG22KATA/RCG22KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.63 | -15° | 6.00 | 4.40 | |
|
AOHG22KATA/AUXG22KRLB
AUXG**K
|
GENERAL | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.63 | -15° | 6.00 | 4.40 | |
|
AOEG22KATA/AUXG22KRLB
AUXG**K
|
FUJITSU | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.63 | -15° | 6.00 | 4.40 | |
|
AOYG22KATA/AUXG22KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.63 | -15° | 6.00 | 4.40 | |
|
AC026RXADKG/AC026TNXDKG
CAC
|
SAMSUNG | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.75 | -20° | 2.60 | 2.10 | |
|
MUZ-DW50VF/MSZ-DW50VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MUZ-HR50VF/MSZ-HR50VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MUZ-HR50VF2/MSZ-HR50VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MOX130-12HFN8-QRD2GW/MSGPBU-12HRFN8-QRD2GW
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
MX1-12RD1H/EF-12RD1H
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
MX1H-12RD1H/EF-12RD1H
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
NRO-12/NRI-12WFI
Nura
|
Inventor | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
DURA-12RD1-OUT/DURA-12RD1-IN
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
LINE-12RD1-OUT/LINE-12RD1-IN
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
PRO-12RD1-OUT/PRO-12RD1-IN
Solunar
|
MIDEA | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
42QCE012D8SM*/38QCE012D8SM
Wall mounted
|
CARRIER | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
AOYG18KATA/AUXG18KRLB
AUXG**K
|
FUJITSU | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
ROG18KATA/RCG18KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
AOHG18KATA/AUXG18KRLB
AUXG**K
|
GENERAL | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
AOEG18KATA/AUXG18KRLB
AUXG**K
|
FUJITSU | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/AUXG18KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.61 | -15° | 5.20 | 3.80 | |
|
GWH09AGC-K6DNA1F
MONOSPLITS
|
GREE | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | -10° | 2.70 | 2.70 | ||
|
GWH09ACCXB-K6DNA1Y
MONOSPLITS
|
GREE | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 4.28 | -10° | 2.70 | 2.70 | |
|
RXC60D / FTXC60D
RXC
|
DAIKIN | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.24 | 3.81 | -14° | 6.21 | 4.10 | |
|
U-100PZ3E5 / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 3.93 | -15° | 9.00 | 9.00 | |
|
U-100PZ3E8 / S-6010PK3E
2021
|
PANASONIC | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 3.93 | -15° | 9.00 | 9.00 | |
|
AUW52U4RS7/ACT52UR4RCC8
Super Inverter R32
|
HISENSE | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.72 | -10° | 5.00 | 4.00 | |
|
UUA1 UL0 / UT12FH NQ0
UU
|
LG | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 4.00 | -10° | 3.40 | 2.80 | |
|
RZAG71NV1 / FAA71B
RZAG
|
DAIKIN | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.58 | 4.20 | 3.42 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FAA71B
RZAG
|
DAIKIN | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.58 | 4.20 | 3.42 | -10° | 6.80 | 4.70 | |
|
RAV-GM1102AT8W-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.92 | 3.90 | -15° | 9.50 | 8.40 | |
|
RAV-GM901ATP-E/RAV-HM901KRTP-E
DI
|
TOSHIBA | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.10 | -15° | 8.00 | 6.30 | |
|
AB25S2SA1FA/1U25S2SM1FA-2
Cassette 620 -Monosplit
|
HAIER | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.72 | -10° | 2.60 | 2.10 | |
|
AB25S2SA1FA(H)/1U25S2SM1FA-2
Cassette 620 -Monosplit
|
HAIER | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.72 | -10° | 2.60 | 2.10 | |
|
RAV-GM561ATP-E1/RAV-HM561BTP-E
DI
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.39 | 4.08 | 3.27 | -15° | 5.00 | 2.80 | |
|
AC71S2SG2FA(H)/1U71S2SR3FA
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
YDAM-070R-09M22/FDHM-070N-09M22
OASIS
|
AIRWELL | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 7.10 | 5.00 | |
|
CU-UZ25CKE / CS-UZ25CKE
2025
|
PANASONIC | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.06 | -15° | 2.50 | 2.10 | |
|
42QZL024D8S*/38QUS024D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
42HU24VDS8C/38HU24VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
SC270HIDS8/AIC270HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.90 | -10° | 7.20 | 5.50 | |
|
RAV-GM402ATP-E/RAV-HM401KRTP-E
DI
|
TOSHIBA | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.24 | 3.57 | -15° | 3.60 | 2.70 | |
|
U-100PZH4E5 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.90 | 3.88 | -20° | 9.50 | 8.00 |