Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(4)
AUX
(0)
BOSCH
(11)
BRYANT
(0)
Buderus
(4)
CARRIER
(5)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(35)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(8)
FUJITSU
(21)
Fujitsu Atlantic
(12)
GENERAL
(22)
GREE
(0)
GSS
(0)
HAIER
(3)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(8)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(9)
MIDEA
(2)
MITSUBISHI ELECTRIC
(16)
Mitsubishi Heavy Industries
(15)
NORD
(0)
Nobu
(0)
PANASONIC
(33)
PITSOS
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(12)
THERMOR
(0)
TOSHIBA
(15)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(0)
Mounting:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
RXM25R9 / FFA25A9
RXM
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.24 | 3.90 | -15° | 2.50 | 2.31 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
AOYG09KMCEN/ASYG09KMCEN
ASY**K
|
FUJITSU | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN
ASH**K
|
GENERAL | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOYG09KMCEN/ASEG09KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AS 007 JDB.UI/1U 007 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.75 | 4.20 | 4.80 | -10° | 2.40 | 2.50 | |
|
SRC20ZS-W/SRK20ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WF
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WFB
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WFT
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
CU-Z25UBEA / CS-Z25UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 4.05 | -15° | 2.50 | 2.70 | |
|
AS07SHBHRA/1U07DEBFRA
Serene
|
HAIER | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO SMART BLANC & UE MONO 2,1 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM BLANC & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM NOIR & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AS07SHBHRA-GA-Q3/1U07DEBFRA-GA-Q3
Serene
|
HAIER | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AS07SHBHRA-GA-Q3/1U07DEBFRA-GA-Q3
Serene
|
HAIER | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AR09TXFYBWKN/AR09TXFYBWKX
RAC
|
SAMSUNG | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.74 | -11° | 2.50 | 2.30 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
H09S1D NS1/H09S1D U12
U12A
|
LG | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.35 | -10° | 2.50 | 2.80 | |
|
H09S1DA NS1 / H09S1DA U12
U12A
|
LG | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.35 | -10° | 2.50 | 2.80 | |
|
AOYG09KVCA/AGYG09KVCA
AGY**K
|
FUJITSU | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOHG09KVCA/AGHG09KVCA
AGH**K
|
GENERAL | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
ROG09KVCA/RGG09KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOEG09KVCA/AGEG09KVCA
AGE**K
|
FUJITSU | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOEG09KVCA/AGYG09KVCA
AGY**K
|
FUJITSU | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOYG09KVCA/AGYG09KVCA
AGY**K
|
Fujitsu Atlantic | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
MUZ-EF25VEH/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.57 | -20° | 2.50 | 2.40 | |
|
CU-Z20XKE / CS-Z20XKEW
2021
|
PANASONIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.80 | 4.52 | -15° | 2.10 | 2.10 | |
|
CU-Z20XKE / CS-XZ20XKEW
2021
|
PANASONIC | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.80 | 4.52 | -15° | 2.10 | 2.10 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOHG09KBTB/AUXG09KVLA
AUH**K
|
GENERAL | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG09KBTB/RCG09KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOEG09KBTB/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
MUZ-EF25VE/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.57 | -15° | 2.50 | 2.40 | |
|
CU-NZ25YKE / CS-NZ25YKE
2023
|
PANASONIC | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
CU-NZ25YKE / CS-NZ25YKE-1
2024
|
PANASONIC | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
RAC-VJ25WHAE / RAK-VJ25RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.64 | -15° | 2.50 | 2.47 | |
|
NH09SP U24A / NH09SP NS1
U24A
|
LG | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 5.25 | -10° | 2.50 | 3.80 | |
|
RAC-VJ18WHAE / RAK-VJ18RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.82 | -15° | 2.00 | 2.30 | |
|
CU-Z25YKEA / CS-Z25YKEA
2022
|
PANASONIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.50 | 4.60 | 4.86 | -15° | 2.50 | 2.70 | |
|
CU-Z25YKEA-1 / CS-Z25YKEA-1
2024
|
PANASONIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.50 | 4.60 | 4.86 | -15° | 2.50 | 2.70 | |
|
MUZ-EF25VGH2/MSZ-EF25VGK2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.10 | 4.60 | 4.57 | -20° | 2.50 | 2.50 | |
|
RAS-10J2AVSG-E1/RAS-B10N4KVRG-E1
HAORI
|
TOSHIBA | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.32 | -15° | 2.50 | 2.50 | |
|
38WHSH025A1A0TEE/40WHPF025D1A0TEE
40WHP
|
CARRIER | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.32 | -15° | 2.50 | 2.50 | |
|
CLC8001i 25 E / CLC8001i-W 25 E
Climate Class 8000i
|
BOSCH | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 |