Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(3)
AUX
(0)
BOSCH
(12)
BRYANT
(0)
Buderus
(4)
CARRIER
(7)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(63)
EQUATION
(0)
FUJI ELECTRIC
(10)
FUJITSU
(24)
Fujitsu Atlantic
(14)
GENERAL
(28)
GREE
(0)
GSS
(0)
HAIER
(3)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(10)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(11)
MIDEA
(2)
MITSUBISHI ELECTRIC
(24)
Mitsubishi Heavy Industries
(23)
NORD
(0)
Nobu
(0)
PANASONIC
(40)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(22)
THERMOR
(0)
TOSHIBA
(23)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-07E2AVG-E/RAS-B07E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
RAS-07E2AVG-E/RAS-B07S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
38WHSM020A1A0TEE/40WHMW020D1A0TEE
40WHM
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
CU-RZ25WKE / CS-RZ25WKEW
2019
|
PANASONIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
CU-RZ25ZKE / CS-RZ25ZKEW
2023
|
PANASONIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
CU-RZ25CKE / CS-RZ25CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
AOYG09KMCEN/ASYG09KMCEN
ASY**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOYG09KMCEN/ASEG09KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
ARXP25N / ATXP25N
ARXP
|
DAIKIN | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.60 | 4.36 | -15° | 2.50 | 2.40 | |
|
ARXP25N9 / ATXP25N9
ARXP
|
DAIKIN | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.60 | 4.36 | -15° | 2.50 | 2.40 | |
|
SRC25ZTL-W/SRK25ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.70 | 4.55 | -10° | 2.50 | 2.70 | |
|
DC09RK UL2 / DC09RK NSJ
UL2
|
LG | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.50 | -10° | 2.50 | 2.80 | |
|
CU-TZ20WKE / CS-TZ20WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.15 | -15° | 2.00 | 1.90 | |
|
P09SND NS0/P09SND U12A
U12A
|
LG | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.60 | 4.32 | -10° | 2.50 | 2.70 | |
|
CU-TZ25WKE / CS-TZ25WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.18 | -15° | 2.50 | 2.40 | |
|
RAS-10CAVG-E/RAS-B10CKVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
RAS-10E2AVG-E/RAS-B10E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
RAS-10E2AVG-E/RAS-B10S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
38WHSM025A1A0TEE/40WHMW025D1A0TEE
40WHM
|
CARRIER | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
CU-TZ20ZKE / CS-TZ20ZKEW
2023
|
PANASONIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.15 | -15° | 2.00 | 2.10 | |
|
CU-TZ20CKE / CS-TZ20CKEW
2025
|
PANASONIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 4.15 | -15° | 2.00 | 2.10 | |
|
CU-TZ25ZKE / CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.60 | 4.18 | -15° | 2.50 | 2.40 | |
|
CU-TZ25CKE / CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.60 | 4.18 | -15° | 2.50 | 2.40 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
SRC20ZS-W/SRK20ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WF
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WFB
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WFT
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
RAC-DJ25WHAE / RAK-DJ25RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.65 | -15° | 2.50 | 2.47 | |
|
AS07SHBHRA/1U07DEBFRA
S-MATT
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO SMART BLANC & UE MONO 2,1 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM BLANC & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM NOIR & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AS07SHBHRA-GA-Q3/1U07DEBFRA-GA-Q3
S-MATT
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AS07SHBHRA-GA-Q3/1U07DEBFRA-GA-Q3
Wall mounted - S
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AR60F09C1AWN/AR60F09C1AWX
RAC
|
SAMSUNG | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.16 | -11° | 2.50 | 2.20 | |
|
AR60F09CAAWN/AR60F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.16 | -11° | 2.50 | 2.20 | |
|
MUZ-BT25VG/MSZ-BT25VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.60 | 4.20 | -15° | 2.50 | 1.90 | |
|
AR70H09CACWN/AR70H09CACWX
RAC
|
SAMSUNG | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.60 | 4.21 | -11° | 2.50 | 2.20 | |
|
ARXP20N / ATXP20N
ARXP
|
DAIKIN | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.64 | 4.77 | -15° | 2.00 | 2.20 | |
|
ARXP20N9 / ATXP20N9
ARXP
|
DAIKIN | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.64 | 4.77 | -15° | 2.00 | 2.20 | |
|
AR09TXFYBWKN/AR09TXFYBWKX
RAC
|
SAMSUNG | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.74 | -11° | 2.50 | 2.30 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
MUZ-BT25VG2/MSZ-BT25VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.60 | 4.20 | -15° | 2.50 | 2.40 | |
|
AOEH09KMCG/ASEH09KMCG
ASE**K
|
FUJITSU | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYH09KMCG/ASYH09KMCG
ASY**K
|
FUJITSU | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHH09KMCG/ASHH09KMCG
ASH**K
|
GENERAL | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
ROH09KMCG/RSH09KMCG
RS**K
|
FUJI ELECTRIC | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 |