Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(5)
AUX
(0)
BOSCH
(10)
BRYANT
(0)
Buderus
(4)
CARRIER
(5)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(55)
EQUATION
(0)
FUJI ELECTRIC
(6)
FUJITSU
(16)
Fujitsu Atlantic
(10)
GENERAL
(18)
GREE
(0)
GSS
(0)
HAIER
(3)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(8)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(9)
MIDEA
(2)
MITSUBISHI ELECTRIC
(25)
Mitsubishi Heavy Industries
(22)
NORD
(0)
Nobu
(0)
PANASONIC
(23)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(18)
THERMOR
(0)
TOSHIBA
(14)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AS 007 NBB.UI/1U 007 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.00 | -10° | 2.10 | 1.90 | |
|
AS 007 JDB.UI/1U 007 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.75 | 4.20 | 4.80 | -10° | 2.40 | 2.50 | |
|
SRC20ZS-W/SRK20ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WF
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WFB
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WFT
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
AS07SHBHRA/1U07DEBFRA
S-MATT
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO SMART BLANC & UE MONO 2,1 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM BLANC & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM NOIR & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AS07SHBHRA-GA-Q3/1U07DEBFRA-GA-Q3
S-MATT
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AS07SHBHRA-GA-Q3/1U07DEBFRA-GA-Q3
Wall mounted - S
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
MUZ-AY20VG/MSZ-AY20VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 4.17 | -20° | 2.00 | 2.30 | |
|
MUZ-AY20VG2/MSZ-AY20VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 4.17 | -20° | 2.00 | 2.30 | |
|
H09S1D NS1/H09S1D U12
U12A
|
LG | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.35 | -10° | 2.50 | 2.80 | |
|
H09S1DA NS1 / H09S1DA U12
U12A
|
LG | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.35 | -10° | 2.50 | 2.80 | |
|
MFZ-KW25VG/MUFZ-KW25VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
AR50F09C1CHN/AR50F09C1CHX
RAC
|
SAMSUNG | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
AOYG09KVCA/AGYG09KVCA
AGY**K
|
FUJITSU | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOHG09KVCA/AGHG09KVCA
AGH**K
|
GENERAL | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
ROG09KVCA/RGG09KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOEG09KVCA/AGEG09KVCA
AGE**K
|
FUJITSU | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOEG09KVCA/AGYG09KVCA
AGY**K
|
FUJITSU | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOYG09KVCA/AGYG09KVCA
AGY**K
|
Fujitsu Atlantic | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
SRC25ZS-W2/SRK25ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.32 | -10° | 2.50 | 2.70 | |
|
SRC25ZS-W2/SRK25ZS-WF
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.32 | -10° | 2.50 | 2.70 | |
|
SRC25ZS-W2/SRK25ZS-WFB
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.32 | -10° | 2.50 | 2.70 | |
|
SRC25ZS-W2/SRK25ZS-WFT
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.32 | -10° | 2.50 | 2.70 | |
|
MUZ-EF25VEH/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.57 | -20° | 2.50 | 2.40 | |
|
AR80F09CAAWN/AR80F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
AR80H09CAAWN/AR80H09CAAWX
RAC
|
SAMSUNG | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
MUZ-EF25VE/MSZ-EF25VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.70 | 4.57 | -15° | 2.50 | 2.40 | |
|
RAC-VJ25WHAE / RAK-VJ25RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.64 | -15° | 2.50 | 2.47 | |
|
NH09SP U24A / NH09SP NS1
U24A
|
LG | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 5.25 | -10° | 2.50 | 3.80 | |
|
MUZ-FT25VGHZ/MSZ-FT25VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.21 | -25° | 2.50 | 3.20 | |
|
MUZ-FT25VGHZ2/MSZ-FT25VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.21 | -25° | 2.50 | 3.20 | |
|
RAC-VJ18WHAE / RAK-VJ18RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.82 | -15° | 2.00 | 2.30 | |
|
CU-Z25YKEA / CS-Z25YKEA
2022
|
PANASONIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.50 | 4.60 | 4.86 | -15° | 2.50 | 2.70 | |
|
CU-Z25YKEA-1 / CS-Z25YKEA-1
2024
|
PANASONIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.50 | 4.60 | 4.86 | -15° | 2.50 | 2.70 | |
|
MUZ-EF25VGH2/MSZ-EF25VGK2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.10 | 4.60 | 4.57 | -20° | 2.50 | 2.50 | |
|
RAS-10J2AVSG-E1/RAS-B10N4KVRG-E1
HAORI
|
TOSHIBA | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.32 | -15° | 2.50 | 2.50 | |
|
38WHSH025A1A0TEE/40WHPF025D1A0TEE
40WHP
|
CARRIER | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.32 | -15° | 2.50 | 2.50 | |
|
CLC8001i 25 E / CLC8001i-W 25 E
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ET
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ES
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ER
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
MUZ-EF25VGH/MSZ-EF25VG(K)(W)(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 9.10 | 4.60 | 4.57 | -20° | 2.50 | 2.40 | |
|
ARXD25A / ATXD25A
ARXD
|
DAIKIN | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.60 | -15° | 2.50 | 2.40 | |
|
RAS-07J2AVSG-E1/RAS-B07G3KVSG-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.00 | -15° | 2.00 | 2.30 | |
|
RAS-07J2AVSG-E1/RAS-B07G3KVSGB-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.00 | -15° | 2.00 | 2.30 |