Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(145)
BOSCH
(136)
BRYANT
(6)
Buderus
(38)
CARRIER
(159)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(869)
DE DIETRICH
(20)
EQUATION
(5)
FUJI ELECTRIC
(168)
FUJITSU
(412)
Fujitsu Atlantic
(207)
GENERAL
(251)
GREE
(139)
GSS
(4)
HAIER
(575)
HEC
(5)
HEIWA
(8)
HISENSE
(408)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(74)
LG
(355)
MIDEA
(843)
MITSUBISHI ELECTRIC
(617)
Mitsubishi Heavy Industries
(401)
NORD
(56)
Nobu
(8)
PANASONIC
(308)
PITSOS
(6)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(207)
THERMOR
(58)
TOSHIBA
(310)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(24)
XTRON
(4)
YORK
(39)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U-100PZ3E8/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.88 | -20° | 9.50 | 8.00 | |
|
Z2UW18GFA3 / ZMNW09GSJL2 / ZMNW09GSJL2
MU
|
LG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.05 | 3.57 | -10° | 5.20 | 3.70 | |
|
AC120RXADKG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.42 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.48 | -20° | 12.00 | 6.50 | |
|
CU-BZ25ZKE / CS-BZ25ZKE
2023
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.30 | 4.09 | -15° | 2.50 | 1.90 | |
|
PUZ-M125VKA2/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA2/PCA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA3/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA3/PCA-M125KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 4.14 | 3.41 | -15° | 12.10 | 8.50 | |
|
SUZ-M50VA/PCA-M50KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.71 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/PCA-M50KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.71 | -10° | 5.00 | 4.30 | |
|
AR5VO-18/AR5VI-18WFI
Aria (AR5)
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.70 | -10° | 5.30 | 4.10 | |
|
RXF42E / FTXF42E
RXF
|
DAIKIN | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.71 | -15° | 4.20 | 3.30 | |
|
RXF42F / FTXF42F
RXF
|
DAIKIN | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.71 | -15° | 4.20 | 3.30 | |
|
AD140S2SM3FA/1UH140P1ERG
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.43 | 13.40 | 10.00 | ||
|
AD140S2SM3FA/1UH140P1ERK
Smart Power - Duct
|
HAIER | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.43 | 13.40 | 10.00 | ||
|
MOX301-18HFN8-QRD0GW/MSAGCU-18HRFNX-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3000iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
GFCAGCU-18HRFN8/GFCAGCU-18HRFN8
Extreme save R32
|
CONFORT AIR | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOD-18N8D0/MAG1-18N8
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOM-18N8D0/MAG2-18N8
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOM-18N8D0-1/MAG2-18N8-1
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
UE-L2C 53 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AC166i.2-5,3 / AC166i.2-5,3 W
Logacool
|
Buderus | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
Ν2UVO-18/Ν2UVI-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOX301-18HFN8-QRD0GW/MSAGCU-18HRFNX-QRD0GW-CARBON
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
X3BP-18N8D0-O/AGF-18NXD1-I
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N2VOCP-18/Ν2VICP-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOX301-18HFN8-QRD0GW-GR/MSAGCU-18HRFNX-QRD0GW-GR
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOX301-18HFN8-QRD0GW-Lite/MSAGCU-18HRFNX-QRD0GW-Lite
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
NPVO-18/NPVI-18WFI
Neo Plus
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
N3VO-18/N3VI-18WFI
Neo
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
VERO-18/VERI-18WFI
Vero
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
CL3000i 53 E / CL3200iU W 53 E
Climate 3000i
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
ASO18DW31/ASI18DW31
Series 4
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
ASO18AW31/ASI18AW31
Series 6
|
BOSCH | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
MOX301-18HFN8/LT/MSAGCU2-18HRFNX
Extreme save R32
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
AC166i.2-5,3 / AC166i.3-5,3 W
Logacool
|
Buderus | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
WIMO-18222.MH / WIM-18222.MH
WIM 222
|
WESTPOINT | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.31 | -25° | 5.30 | 4.20 | |
|
38QUS018D8S2-2/42QHE09D8SH*
Wall mounted
|
CARRIER | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.56 | 4.00 | 4.29 | -10° | 5.79 | 4.50 | |
|
RAS-3HVRC3 / RPK-3.0FSR(H)M
UTOPIA PRIME
|
HITACHI | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.11 | 3.90 | 3.19 | -25° | 7.10 | 5.60 | |
|
U-25PZ3E5/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 4.52 | -15° | 2.50 | 2.50 | |
|
RXF20E / FTXF20E
RXF
|
DAIKIN | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.75 | -15° | 2.00 | 2.20 | |
|
RXF20F / FTXF20F
RXF
|
DAIKIN | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.75 | -15° | 2.00 | 2.20 | |
|
AR60F09C1KWN/AR60F09C1KWX
RAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AR70F09C1DBN/AR70F09C1DBX
RAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AF50S2SD1FA(H)/1U50S2SJ2FA-2
Console-Monosplit
|
HAIER | Console | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.24 | -10° | 5.00 | 3.40 | |
|
RXC60E / FTXC60E
RXC
|
DAIKIN | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.81 | -14° | 6.20 | 4.10 | |
|
ARXC60E / ATXC60E
ARXC
|
DAIKIN | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.71 | -14° | 6.20 | 4.10 |