Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(1)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(10)
EQUATION
(0)
FUJI ELECTRIC
(1)
FUJITSU
(7)
Fujitsu Atlantic
(1)
GENERAL
(5)
GREE
(0)
GSS
(0)
HAIER
(2)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(1)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(6)
MIDEA
(4)
MITSUBISHI ELECTRIC
(16)
Mitsubishi Heavy Industries
(0)
NORD
(1)
Nobu
(0)
PANASONIC
(11)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(9)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZAG35B / FFA35A9
RZAG
|
DAIKIN | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -10° | 3.50 | 4.20 | |
|
RZAG35B / FDXM35F9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
RZAG35B / FNA35A9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
RZAG35A / FFA35A9
RZAG
|
DAIKIN | Cassette | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.80 | 3.71 | -20° | 3.50 | 4.20 | |
|
RZAG35A / FDXM35F9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RZAG35A / FNA35A9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
CU-CZ35WKE / CS-CZ35WKE
2020
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.08 | -25° | 3.50 | 3.60 | |
|
CU-CZ35ZKE / CS-CZ35ZKE
2023
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.12 | -25° | 3.50 | 3.60 | |
|
RAS-35G3AVSG-ND/RAS-B35G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.77 | -25° | 3.50 | 3.60 | |
|
MUFZ-KW35VGHZ2/MFZ-KW35VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
AS35PCHHRA-NR/1U35KEFFRA-NR
Pearl Nordic
|
HAIER | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.50 | -10° | 3.50 | 3.90 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
MFZ-KW35VG/MUFZ-KW35VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
AOYG12KVCA/AGYG12KVCA
AGY**K
|
FUJITSU | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOHG12KVCA/AGHG12KVCA
AGH**K
|
GENERAL | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
ROG12KVCA/RGG12KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOEG12KVCA/AGEG12KVCA
AGE**K
|
FUJITSU | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOEG12KVCA/AGYG12KVCA
AGY**K
|
FUJITSU | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AOYG12KVCA/AGYG12KVCA
AGY**K
|
Fujitsu Atlantic | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.10 | 3.70 | -15° | 3.50 | 3.50 | |
|
AS35XCHHRA-NR/1U35KEHFRA-NR
Wall mounted - EXPERT Nordic
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.20 | -10° | 3.50 | 3.60 | |
|
RZAG35B / FBA35A9
RZAG
|
DAIKIN | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 4.10 | 4.40 | -10° | 3.50 | 4.20 | |
|
MUFZ-KW25VGHZ2/MFZ-KW25VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
MFZ-KW25VG/MUFZ-KW25VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
RZAG35A / FBA35A9
RZAG
|
DAIKIN | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.12 | 4.10 | 4.40 | -20° | 3.50 | 4.20 | |
|
AOYG12KMCEN/ASYG12KMCEN
ASY**K
|
FUJITSU | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
AOHG12KMCEN/ASHG12KMCEN
ASH**K
|
GENERAL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
AOYG12KMCEN/ASEG12KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
AOHG12KMCEN/ASHG12KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.17 | -25° | 3.40 | 3.60 | |
|
NH12SP U24A / NH12SP NS1
U24A
|
LG | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.82 | -10° | 3.50 | 3.80 | |
|
NH09SP U24A / NH09SP NS1
U24A
|
LG | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 5.25 | -10° | 2.50 | 3.80 | |
|
RAS-35G3AVSG-ND/RAS-B35G3KVSG-ND
SHORAI
|
TOSHIBA | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 5.10 | 4.57 | -25° | 3.50 | 3.60 | |
|
RAS-35G3AVSG-ND/RAS-B35G3KVSGB-ND
SHORAI
|
TOSHIBA | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 5.10 | 4.57 | -25° | 3.50 | 3.60 | |
|
RAS-35G3AVSG-ND/RAS-B35N4KVRG-ND
HAORI
|
TOSHIBA | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 5.10 | 4.42 | -25° | 3.50 | 3.60 | |
|
CU-NZ35YKE / CS-NZ35YKE
2023
|
PANASONIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 5.00 | 4.65 | -25° | 3.50 | 3.60 | |
|
CU-NZ35YKE / CS-NZ35YKE-1
2024
|
PANASONIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.00 | 5.00 | 4.65 | -25° | 3.50 | 3.60 | |
|
MUZ-FT35VGHZ/MSZ-FT35VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 3.92 | -25° | 3.50 | 4.00 | |
|
MUZ-FT35VGHZ2/MSZ-FT35VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.60 | 3.92 | -25° | 3.50 | 4.00 | |
|
RAC-35FXE / RAF-35RXE
RAC-FXE
|
HITACHI | Floor standing | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 3.90 | -20° | 3.50 | 3.53 | |
|
MOX430-09HFN8-QRE1GW/MSEX1BU-09HRFN8-QRE1GW
Raynor
|
MIDEA | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.10 | 4.42 | -10° | 2.70 | 4.00 | |
|
EXH-09RE1N-O/EX-09RE1N-I
Raynor
|
MIDEA | Wall mounted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.10 | 4.42 | -10° | 2.70 | 4.00 | |
|
CU-Z35UFEA-1 / CS-Z35UFEAW-1
2018
|
PANASONIC | Console | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.06 | -25° | 3.50 | 3.60 | |
|
CU-Z35CFEA-1 / CS-Z35CFEAW-1
2025
|
PANASONIC | Console | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.80 | 4.60 | 4.06 | -25° | 3.50 | 3.60 | |
|
EXH-12RE1N-O/EX-12RE1N-I
Raynor
|
MIDEA | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.42 | -10° | 3.50 | 4.00 | |
|
MOX430-12HFN8-QRE1GW/MSEX1BU-12HRFN8-QRE1GW
Raynor
|
MIDEA | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 5.10 | 4.42 | -10° | 3.50 | 4.00 | |
|
F12MT U24 / F12MT NSM
U24A
|
LG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 5.10 | -10° | 3.50 | 3.80 | |
|
F09MT U24 / F09MT NSM
U24A
|
LG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.40 | -10° | 2.50 | 3.70 | |
|
NH12SP2 U24A / NH12SP2 NS2
U24A
|
LG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 3.50 | 3.80 | |
|
NH09SP2 U24A / NH09SP2 NS2
U24A
|
LG | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 5.42 | -10° | 2.50 | 3.80 | |
|
ND35MDAHRA/1N35MEAFRA-W
NORD - MSP Duct
|
NORD | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 3.50 | 3.60 | |
|
CL9100i 85 E / CL9100i-W 85 E
Climate 9100i
|
BOSCH | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 5.37 | -25° | 3.50 | 4.00 |