Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(28)
ATLANTIC
(19)
AUX
(0)
BOSCH
(56)
BRYANT
(3)
Buderus
(14)
CARRIER
(42)
CIAT
(6)
COLIBRI
(3)
CONFORT AIR
(2)
Candy
(10)
DAIKIN
(161)
EQUATION
(2)
FUJI ELECTRIC
(57)
FUJITSU
(116)
Fujitsu Atlantic
(66)
GENERAL
(98)
GREE
(53)
GSS
(2)
HAIER
(124)
HEC
(2)
HEIWA
(3)
HISENSE
(166)
HITACHI
(29)
IVT
(5)
Inventor
(48)
KAYSUN
(15)
LG
(111)
MIDEA
(274)
MITSUBISHI ELECTRIC
(103)
Mitsubishi Heavy Industries
(46)
NORD
(19)
Nobu
(4)
PANASONIC
(100)
RIELLO
(8)
Rotenso
(0)
SAMSUNG
(77)
THERMOR
(26)
TOSHIBA
(69)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(12)
YORK
(8)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CU-BZ35ZKE / CS-BZ35ZKE
2023
|
PANASONIC | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.72 | -15° | 3.30 | 2.40 | |
|
ARXF20E / ATXF20E
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 | |
|
ARXF20F / ATXF20F
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 | |
|
MOX104-09HFNX-QRD1GW/MSCB1BU-09HRFN8-QRD1GW
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
CB1-09HFNX-O/CB1-09HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
MOM-09N8D0/MCB1-07N8
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
MOM-09N8D0/MCB1-09N8
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
MOX104-09HFN8-QRD1GW/MSCB1BU-09HRFN8-QRD1GW
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
CB1-09HFNX-O(B)/CB1-09HRFN8-I(B)
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
CB1-09HFNX-O(A)/CB1-09HRFN8-I(A)
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
MOM-09NXD0/MCB1-07N8
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
MOM-09NXD0/MCB1-09N8
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
CB1-09HFNX-O(R)/CB1-09HFN8-I(R)
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
CB1-09HFNX-O-GR/CB1-09HRFN8-I-GR
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
CB1-09HFNX-O/CB1-09HRFN8-I
Breezeless E
|
MIDEA | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.60 | 4.10 | 4.10 | -10° | 2.80 | 2.60 | |
|
AR60F12C1KWN/AR60F12C1KWX
RAC
|
SAMSUNG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
AR70F12C1DBN/AR70F12C1DBX
RAC
|
SAMSUNG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
RZAG35A / FDXM35F9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RZAG35A / FNA35A9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
MUZ-WN35VA/MSZ-WN35VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -15° | 3.10 | 2.40 | |
|
ARXF35F / ATXF35F
ARXF
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.72 | -15° | 3.50 | 2.60 | |
|
SRC20ZTL-W/SRK20ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.40 | 4.22 | -10° | 2.00 | 2.40 | |
|
UUA1 UL0 / CT09F NR0
UU
|
LG | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 4.30 | -10° | 2.50 | 2.80 | |
|
UUA1 UL0 / CT12F NR0
UU
|
LG | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.71 | -10° | 3.40 | 2.80 | |
|
ARXF25F / ATXF25F
ARXF
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
AR70H12CACBN/AR70H12CACBX
RAC
|
SAMSUNG | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
ARXM35R9 / ADEA35A
ARXM
|
DAIKIN | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 4.00 | 3.97 | -15° | 3.40 | 2.90 | |
|
RAC-CJ35WHAE / RAK-CJ35PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 3.71 | -15° | 3.20 | 2.80 | |
|
RAS-25E2AVG-ND/RAS-B25E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.45 | 4.27 | -25° | 2.50 | 2.80 | |
|
RXF35E / FTXF35E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.72 | -15° | 3.50 | 2.60 | |
|
RXF35F / FTXF35F
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.72 | -15° | 3.50 | 2.60 | |
|
AC035RXADKG/AC035TNXDKG
CAC
|
SAMSUNG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.10 | 3.31 | -20° | 3.50 | 2.10 | |
|
RXF25E / FTXF25E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
RXF25F / FTXF25F
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
CU-BZ35CKE / CS-BZ35CKE
2025
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.72 | -15° | 3.30 | 2.40 | |
|
AR60F09C1KWN/AR60F09C1KWX
RAC
|
SAMSUNG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AR70F09C1DBN/AR70F09C1DBX
RAC
|
SAMSUNG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
U-25PZ3E5/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 4.52 | -15° | 2.50 | 2.50 | |
|
CU-BZ25ZKE / CS-BZ25ZKE
2023
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.30 | 4.09 | -15° | 2.50 | 1.90 | |
|
RXF20E / FTXF20E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.75 | -15° | 2.00 | 2.20 | |
|
RXF20F / FTXF20F
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.75 | -15° | 2.00 | 2.20 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 | |
|
AOEH07KLTA/ASEH07KLTA
ASE**K
|
FUJITSU | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
AOHH07KLTA/ASHH07KLTA
ASH**K
|
GENERAL | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
ROH07KLTA/RSH07KLTA
RS**K
|
FUJI ELECTRIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
AOHH07KLTA/ASHH07KLTBL
ASH**K
|
GENERAL | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
AOEH07KLTA/ASEH07KLTBL
ASE**K
|
FUJITSU | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.10 | 3.75 | -15° | 2.00 | 2.20 | |
|
SUZ-M25VA2/MFZ-KT25VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.71 | -10° | 2.50 | 2.20 | |
|
AR70H09CACBN/AR70H09CACBX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
A09GA1 U18 / A09GA1 NSE
U18A
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.30 | 4.08 | -10° | 2.60 | 2.80 |