Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(65)
ATLANTIC
(34)
AUX
(42)
BOSCH
(105)
BRYANT
(5)
Buderus
(34)
CARRIER
(103)
CIAT
(23)
COLIBRI
(5)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(443)
EQUATION
(5)
FUJI ELECTRIC
(110)
FUJITSU
(254)
Fujitsu Atlantic
(132)
GENERAL
(176)
GREE
(92)
GSS
(4)
HAIER
(346)
HEC
(5)
HEIWA
(8)
HISENSE
(299)
HITACHI
(92)
IVT
(10)
Inventor
(103)
KAYSUN
(28)
LG
(241)
MIDEA
(613)
MITSUBISHI ELECTRIC
(300)
Mitsubishi Heavy Industries
(87)
NORD
(43)
Nobu
(8)
PANASONIC
(207)
RIELLO
(25)
Rotenso
(0)
SAMSUNG
(141)
THERMOR
(51)
TOSHIBA
(187)
Viessmann
(12)
Vulcano
(13)
WESTPOINT
(21)
YORK
(20)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM562ATP-E/RAV-HM561CTP-E
DI
|
TOSHIBA | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.34 | 3.90 | -15° | 5.00 | 2.80 | |
|
SUZ-M50VA/PLA-M50EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.10 | 3.46 | -10° | 5.50 | 4.30 | |
|
SUZ-M50VA2/PLA-M50EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.10 | 3.46 | -10° | 5.50 | 4.30 | |
|
AR70F18C1AWN/AR70F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1AWN/AR60F18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18CAAWN/AR60F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR60F18C1KWN/AR60F18C1KWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR70H18C1AWN/AR70H18C1AWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
AR70H18CACWN/AR70H18CACWX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.73 | -11° | 5.00 | 3.80 | |
|
MX4-22RD1-EF/EF-22RD1
Solunar
|
MIDEA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.10 | 3.71 | -10° | 6.10 | 4.80 | |
|
RAS-35G3AVSG-ND/RAS-B35G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.77 | -25° | 3.50 | 3.60 | |
|
RAC-25NPE / RAD-25RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.84 | |
|
RAC-25NPE / RAI-25RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.84 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
WIM-09323.MH
WIM 323
|
WESTPOINT | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
AOEG14KBTB/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG14KBTB/ARXH14KMTAP
ARX**K
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOYG14KBTB/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOYG14KBTB/ARXH14KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 4.30 | 3.80 | |
|
AS 007 NBB.UI/1U 007 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.00 | -10° | 2.10 | 1.90 | |
|
MUZ-SF35VE/MSZ-SF35VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 3.88 | -15° | 3.50 | 2.90 | |
|
RXC50D / FTXC50D
RXC
|
DAIKIN | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.45 | 4.42 | 3.71 | -14° | 5.08 | 3.90 | |
|
SUZ-M50VA/SLZ-M50FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.20 | 3.20 | -10° | 4.60 | 3.60 | |
|
SUZ-M50VA2/SLZ-M50FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.20 | 3.20 | -10° | 4.60 | 3.60 | |
|
U-71PZ3E5A/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.40 | 4.10 | -15° | 6.90 | 5.20 | |
|
MUZ-AY15VG/MSZ-AY15VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -15° | 1.50 | 1.60 | |
|
MUZ-AY15VG2/MSZ-AY15VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -15° | 1.50 | 1.60 | |
|
AC026RXADKG/AC026RNJDKG
CAC
|
SAMSUNG | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.30 | -20° | 2.60 | 2.00 | |
|
RZAG71NV1 / FVA71A
RZAG
|
DAIKIN | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.34 | 4.05 | 3.39 | -10° | 6.80 | 4.70 | |
|
RZAG71NY1 / FVA71A
RZAG
|
DAIKIN | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.34 | 4.05 | 3.39 | -10° | 6.80 | 4.70 | |
|
RXC50E / FTXC50E
RXC
|
DAIKIN | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.40 | 3.71 | -14° | 5.10 | 3.90 | |
|
RZASG71MV1 / FBA71A9
RZASG
|
DAIKIN | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.01 | -10° | 6.80 | 4.50 | ||
|
SUZ-M60VA/SEZ-M60DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA/SEZ-M60DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
SUZ-M60VA2/SEZ-M60DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.50 | 4.20 | 3.61 | -10° | 6.10 | 4.60 | |
|
AS71S2SF1FA-MW3/1U71S2ST1FA
Super Match mono-Flexis Plus
|
HAIER | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
AS71S2SF1FA-WH/1U71WEGFRA
RAC Flexis
|
HAIER | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
Virtus-24K-IN/Virtus-24K-OUT
Wall mounted - Tundra Plus
|
EQUATION | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.26 | -10° | 7.00 | 5.60 | |
|
AOYG12KBTB/ARXG12KLLAP
ARY**K
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOHG12KBTB/ARXG12KLLAP
ARH**K
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
ROG12KBTB/RDG12KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOEG12KBTB/ARXG12KLLAP
ARXG**K
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
AOYG12KBTB/ARXG12KLLAP
ARY**K
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.80 | -15° | 3.50 | 3.40 | |
|
AR50F07C1AHN/AR50F07C1AHX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.20 | 4.68 | -11° | 2.00 | 2.10 | |
|
5MWXM90A9 / FBA71A9
5MWXM
|
DAIKIN | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.00 | 3.89 | -15° | 6.80 | 4.60 | |
|
RAV-GM801ATP-E/RAV-HM801BTP-E
DI
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.20 | 4.13 | 3.32 | -15° | 6.70 | 5.10 | |
|
MUZ-SF35VEH/MSZ-SF35VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.88 | -20° | 3.50 | 2.90 | |
|
CU-RZ35ZKE / CS-RZ35ZKEW
2023
|
PANASONIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
AOYG12KETA /ASYG12KETE
ASY**K
|
FUJITSU | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KETA /ASYG12KETE-B
ASY**K
|
FUJITSU | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 |