Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(11)
BOSCH
(2)
BRYANT
(0)
Buderus
(2)
CARRIER
(2)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
DE DIETRICH
(3)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(8)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(3)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(0)
NORD
(2)
Nobu
(0)
PANASONIC
(0)
PITSOS
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AS35QUA1-H/1U35QUA1
NORD - P Premium
|
NORD | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.10 | -10° | 3.30 | 2.80 | |
|
AG-12RD6N7H-O/AG-12RD6N7-I
Extreme save R290
|
MIDEA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
MOX331-12HFN7-QRD6GW/MSAGBU-12HRFN7-QRD6GW(A)
Extreme save R290
|
MIDEA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
MOX331-12HFN7-QRD6GW/MSAGBU-12HRFN7-QRD6GW(B)
Extreme save R290
|
MIDEA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL6000iP 35 / CL6000iP W 35
Climate 6000iP
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL6000iP 35 / CL6000iP W 35 F
Climate 6000iP
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
AC176iP-3,5 / AC176iP-3,5 W
AC176iP
|
Buderus | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
AC176iP-3,5 / AC176iP-3,5 W S
AC176iP
|
Buderus | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
42QCE009D8SH*/38QCE009D8SH*
Wall mounted
|
CARRIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.30 | -10° | 3.50 | 2.60 | |
|
42QCE012D8SH*/38QCE012D8SH*
Wall mounted
|
CARRIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.30 | -10° | 3.52 | 2.60 | |
|
AS35SBBHRA-MW/1U35DEBFRA-S
Serene
|
HAIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MB/1U35DEBFRA-S
Serene
|
HAIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MWV/1U35DEBFRA-SH
Serene
|
HAIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MW/1U35DEBFRA-SH
Serene
|
HAIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MB/1U35DEBFRA-SH
Serene
|
HAIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35PBBHRA-PA/1U35DEBFRA-S
HAIER-PEARL PREMIUM
|
HAIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35RBBHRA-RBS/1U35DEBFRA-S
HAIER-TIDE PREMIUM
|
HAIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SAT1-W/US35SAT1
NORD - S
|
NORD | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-S/1U35DEBFRA-S
Serene
|
HAIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
RTX52MCA-T1A/FTXM52CA-A
C SERIES
|
AUX | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
RTX71MCA-T1A/FTXM71CA-A
C SERIES
|
AUX | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.08 | -10° | 6.10 | 5.40 | |
|
ASW-H18E3A4/MAR3DI-C7 / ASW-H18E3A4/MAR3DI-C7
M SERIES
|
AUX | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
MOST 50 (7886451) / UMT 50 (7886445)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
MOST 50 (7886451) / UMT 2 50 (7906264)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
ASW-H18E3A4/CCR3DI-C7 / ASW-H18E3A4/CCR3DI-C7
C SERIES
|
AUX | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
RTX52MCU1-T1A/FTXM52CU1-A
C SERIES
|
AUX | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
ASW-H18E3A4/CAR3DI-C7 / ASW-H18E3A4/CAR3DI-C7
C SERIES
|
AUX | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
ASW-H18E3A4/CMR3DI-C7 / ASW-H18E3A4/CMR3DI-C7
C SERIES
|
AUX | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.20 | -10° | 5.40 | 4.40 | |
|
ASW-H24F4A4/CAR3DI-C8 / ASW-H24F4A4/CAR3DI-C8
C SERIES
|
AUX | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.08 | -10° | 6.10 | 5.40 | |
|
ASW-H24F4A4/MAR3DI-C8 / ASW-H24F4A4/MAR3DI-C8
M SERIES
|
AUX | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.04 | -10° | 6.10 | 5.40 | |
|
MOST 70 (7906267) / UMT 2 70 (7906265)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.04 | -10° | 6.10 | 5.40 | |
|
RTX71MCU1-T1A/FTXM71CU1-A
C SERIES
|
AUX | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.08 | -10° | 6.10 | 5.40 | |
|
ASW-H24F1A4/CMR3DI-C8 / ASW-H24F1A4/CMR3DI-C8
C SERIES
|
AUX | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 4.60 | 3.08 | -10° | 6.10 | 5.40 |