Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(11)
ATLANTIC
(12)
AUX
(0)
BOSCH
(14)
BRYANT
(0)
Buderus
(8)
CARRIER
(24)
CIAT
(1)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(2)
DAIKIN
(39)
EQUATION
(0)
FUJI ELECTRIC
(7)
FUJITSU
(16)
Fujitsu Atlantic
(9)
GENERAL
(16)
GREE
(5)
GSS
(0)
HAIER
(85)
HEC
(0)
HEIWA
(1)
HISENSE
(75)
HITACHI
(13)
IVT
(2)
Inventor
(25)
KAYSUN
(2)
LG
(13)
MIDEA
(114)
MITSUBISHI ELECTRIC
(70)
Mitsubishi Heavy Industries
(56)
NORD
(11)
Nobu
(0)
PANASONIC
(20)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(20)
THERMOR
(15)
TOSHIBA
(55)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(9)
YORK
(1)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAS-13J2AVSG-E1/RAS-B13J2FVG-E
Console
|
TOSHIBA | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 4.54 | 3.31 | -15° | 3.50 | 3.00 | |
|
SRC35ZSP-W1/SRK35ZSP-W1
ZSP-W
|
Mitsubishi Heavy Industries | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.50 | 3.87 | -10° | 3.20 | 2.80 | |
|
RXC25E / FTXC25E
RXC
|
DAIKIN | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.50 | 3.79 | -14° | 2.60 | 2.20 | |
|
CU-RZ35WKE / CS-RZ35WKEW
2019
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
RAS-35E2AVG-ND/RAS-B35E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.50 | 3.89 | -25° | 3.50 | 3.40 | |
|
RAS-07E2AVG-E/RAS-B07E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
RAS-07E2AVG-E/RAS-B07S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
38WHSM020A1A0TEE/40WHMW020D1A0TEE
40WHM
|
CARRIER | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.19 | 4.60 | 3.91 | -15° | 2.00 | 2.00 | |
|
CU-RZ35ZKE / CS-RZ35ZKEW
2023
|
PANASONIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
FDC71VNP-W/SRK71ZR-W
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 4.55 | 3.78 | -15° | 7.10 | 5.70 | |
|
AR50F15C1AHN/AR50F15C1AHX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.50 | 3.47 | -11° | 4.30 | 2.70 | |
|
CU-RZ35CKE / CS-RZ35CKEW
2025
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
MUZ-BT35VG2/MSZ-BT35VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.87 | -15° | 3.50 | 2.50 | |
|
AS35XV2EW/QH35XV2AG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
AS35XV2EW/QH35XV2BG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
AS35XV2FW/QH35XV2AG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
AS35XV2FW/QH35XV2BG
Energy Nordic Pro
|
HISENSE | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.80 | -10° | 3.50 | 2.90 | |
|
MUZ-BT35VG/MSZ-BT35VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.87 | -15° | 3.50 | 2.40 | |
|
RAS-13CAVG-E/RAS-B13CKVG-E
SEIYA
|
TOSHIBA | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.91 | -15° | 3.30 | 2.70 | |
|
RAS-13E2AVG-E/RAS-B13E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.91 | -15° | 3.30 | 2.70 | |
|
CU-TZ50WKE / CS-TZ50WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50ZKE / CS-TZ50ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50CKE / CS-TZ50CKEW
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
RZAG35B / FTXM35A
RZAG
|
DAIKIN | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.60 | 3.85 | -10° | 3.50 | 2.60 | |
|
RAS-10CAVG-E/RAS-B10CKVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
RAS-10E2AVG-E/RAS-B10E2KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
RAS-10E2AVG-E/RAS-B10S4KVG-E
SEIYA
|
TOSHIBA | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
38WHSM025A1A0TEE/40WHMW025D1A0TEE
40WHM
|
CARRIER | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 2.50 | 2.40 | |
|
FM48AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM49AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM48AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FM49AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
MOX230-12AFN8-QRD6GW/MSAGBU-12HRFN8-QRD1GW(GA)
Extreme save R32
|
MIDEA | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.81 | -10° | 3.50 | 2.40 | |
|
CL4000i 35 E / CL4000iU W 35 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.81 | -10° | 3.50 | 2.40 | |
|
YHKF12XEEDMH-RY / YHKF12YEEDMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.60 | 3.80 | -10° | 3.50 | 2.60 | |
|
SRC50ZS-W/SRK50ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
SRC50ZS-W/SRK50ZS-WF
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
SRC50ZS-W/SRK50ZS-WFB
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
SRC50ZS-W/SRK50ZS-WFT
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -10° | 5.00 | 3.80 | |
|
AOEH36KMTB/ASEH36KMTB
ASE**K
|
FUJITSU | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOHH36KMTB/ASHH36KMTB
ASY**K
|
GENERAL | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOYH36KMTB/ASYH36KMTB
ASY**K
|
FUJITSU | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
ROH36KMTB/RSH36KMTB
RS**K
|
FUJI ELECTRIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOYH36KMTB/ASYH36KMTB
ASY**K
|
Fujitsu Atlantic | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
NAGANO U.I 3500W R32 / E1U35LV2-NG
NAGANO MURALE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
NAGANO MURALE PURE IM35V2-NG / E1U35LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
DR2VO-12/DR2VI-12WFI
Dark
|
Inventor | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
MFVO-12/MFVI-12WFI
Comfort
|
Inventor | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 |