Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(70)
ATLANTIC
(38)
AUX
(59)
BOSCH
(73)
BRYANT
(6)
Buderus
(28)
CARRIER
(106)
CIAT
(35)
COLIBRI
(5)
CONFORT AIR
(3)
Candy
(16)
DAIKIN
(305)
EQUATION
(5)
FUJI ELECTRIC
(113)
FUJITSU
(293)
Fujitsu Atlantic
(143)
GENERAL
(155)
GREE
(71)
GSS
(4)
HAIER
(520)
HEC
(5)
HEIWA
(6)
HISENSE
(270)
HITACHI
(118)
IVT
(3)
Inventor
(135)
KAYSUN
(62)
LG
(265)
MIDEA
(718)
MITSUBISHI ELECTRIC
(463)
Mitsubishi Heavy Industries
(266)
NORD
(51)
Nobu
(8)
PANASONIC
(155)
RIELLO
(38)
Rotenso
(8)
SAMSUNG
(160)
THERMOR
(56)
TOSHIBA
(216)
Viessmann
(22)
Vulcano
(16)
WESTPOINT
(17)
YORK
(35)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GP1101AT-E/RAV-HM1101KRTP-E
SDI
|
TOSHIBA | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.36 | 4.42 | 3.58 | -27° | 10.00 | 9.20 | |
|
FDC125VNX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 5.10 | 3.10 | 12.50 | 11.40 | ||
|
RAC-VJ25NHAE / RAD-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.28 | 4.00 | -15° | 2.50 | 2.57 | |
|
FDC125VNX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.80 | 3.10 | 12.50 | 11.40 | ||
|
RAS-4HVRC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.18 | 4.38 | 3.73 | -20° | 10.00 | 8.70 | |
|
RAS-5HVNC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.34 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-5HRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.79 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAS-4HVNC2E / RPIH-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.44 | 3.79 | -20° | 10.00 | 8.70 | |
|
AC120BXAPNG / AC120BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.40 | 4.00 | -25° | 12.10 | 9.50 | |
|
U-71PZH4E8 / S-6071PT3E
2023
|
PANASONIC | Ceiling suspended | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.70 | 3.96 | -20° | 6.80 | 4.70 | |
|
AUV125UR4RC8/AUW125U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
AUV125UR4RC8/AUW125U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
RAS-5HVRC2E / RPIH-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.06 | 4.36 | 3.52 | -20° | 11.90 | 11.93 | |
|
RAC-VJ35NHAE / RAD-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.70 | |
|
U-71PZH4E5 / S-6071PT3E
2023
|
PANASONIC | Ceiling suspended | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.70 | 3.96 | -20° | 6.80 | 4.70 | |
|
AC071BXAPKG/AC071BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.30 | 3.79 | -25° | 6.80 | 4.70 | |
|
AC071BXAPNG/AC071BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.30 | 3.79 | -25° | 6.80 | 4.70 | |
|
RAV-GP1401AT-E1/RAV-HM1401FT-E
SDI
|
TOSHIBA | Floor standing | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.49 | 4.38 | 3.00 | -27° | 12.30 | 9.60 | |
|
PUZ-ZM140YDA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.09 | 5.09 | 3.60 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.10 | 5.09 | 3.60 | -20° | 13.40 | 10.60 | |
|
U-60PZH3E5 / S-6071PF3E
2021
|
PANASONIC | Ducted | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 3.74 | -20° | 5.70 | 4.70 | |
|
PUZ-ZM140VDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.15 | 5.10 | 3.60 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.15 | 5.10 | 3.60 | -20° | 13.40 | 10.60 | |
|
AC052BXAPKG/AC052BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.30 | 4.60 | 3.70 | -25° | 5.00 | 3.90 | |
|
PUZ-ZM125YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.44 | 5.13 | 3.88 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 95 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.44 | 5.13 | 3.88 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.51 | 5.13 | 3.88 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.51 | 5.13 | 3.88 | -20° | 12.50 | 9.30 | |
|
AC052BXAPKG/AC052BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 97 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.85 | -25° | 5.00 | 4.00 | |
|
AC035BXAPKG/AC035BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.64 | -25° | 3.50 | 2.30 | |
|
RAC-XJ35FHAE / RAF-XJ35RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 8.20 | 4.61 | 3.90 | -20° | 3.50 | 3.02 | |
|
RAC-XJ50FHAE / RAF-XJ50RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 7.30 | 4.30 | 3.90 | -20° | 5.00 | 4.19 | |
|
NB71MBAHRA/1N71WEAFRA-W
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 6.10 | 4.05 | 3.15 | -10° | 6.20 | 4.60 | |
|
NB25MBAHRA/1N25MEAFRA
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 7.50 | 4.20 | 3.80 | -10° | 2.50 | 2.60 | |
|
NB35MBAHRA/1N35MEAFRA
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 7.80 | 4.10 | 3.80 | -10° | 3.50 | 2.80 | |
|
NB35MBAHRA/1N35MEAFRA-W
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 7.80 | 4.10 | 3.80 | -10° | 3.50 | 2.80 | |
|
NB50MBAHRA/1N50KEAFRA
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 6.30 | 4.05 | 3.40 | -10° | 5.00 | 4.00 | |
|
NB50MBAHRAA/1N50KEAFRA-W
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 6.30 | 4.05 | 3.40 | -10° | 5.00 | 4.00 | |
|
U-200PZH4E8 / S-1014PU3E(2x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 | |
|
U-250PZH4E8 / S-1014PU3E(2x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 6.97 | 4.18 | 3.75 | -20° | 22.00 | 17.20 | |
|
U-200PZH4E8 / S-6071PU3E(3x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-3650PU3E(4x)
2024
|
PANASONIC | 4-way cassette | — No score: too few class peers or too few declared metrics. Why? | 7.20 | 4.21 | 3.80 | -20° | 19.00 | 16.00 | |
|
U-250PZH4E8 / S-6071PU3E(4x)
2024
|