Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(1)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(3)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(4)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(6)
Fujitsu Atlantic
(3)
GENERAL
(3)
GREE
(0)
GSS
(0)
HAIER
(29)
HEC
(0)
HEIWA
(0)
HISENSE
(3)
HITACHI
(0)
IVT
(0)
Inventor
(4)
KAYSUN
(1)
LG
(3)
MIDEA
(7)
MITSUBISHI ELECTRIC
(12)
Mitsubishi Heavy Industries
(8)
NORD
(5)
Nobu
(1)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(1)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(9)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC250VSA/FDU250VG
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.83 | 3.52 | 3.75 | 24.00 | 14.20 | ||
|
UUA1 UL0 / CM18F NA0
UU
|
LG | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.80 | 3.50 | -10° | 5.00 | 2.80 | |
|
5U90S2SSS5FA/AS71S2SF1FA-MW3+AS50S2SF1FA-MW3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS50S2SJ1FA-3+AS50S2SJ1FA-3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS50XCAHRA+AS50XCAHRA
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS71S2SF2FA-3+AS50S2SF2FA-3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5MWXM68A9 / FBA35A9 / FBA35A9
5MWXM
|
DAIKIN | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.80 | 3.29 | -15° | 6.80 | 3.60 | |
|
NOBO-09/NOBI-09WFI
Nobu
|
Nobu | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.20 | -10° | 2.70 | 2.30 | |
|
RAV-GV1101ATP-E/RAV-HM1101BTP-E
DIC
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.33 | -15° | 9.50 | 7.60 | |
|
ABH105H1ERG/1U105S2SS1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 6.00 | |
|
AB105S2SR1FA(H)/1U105S2SS1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 6.00 | |
|
RAS-16B2AVG-E2/RAS-B16B2KVG-E2
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
RAS-16B2AVG-E2/RAS-B16B2KV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
RAS-16LAV2G-E/RAS-B16LKV2G-E
SEIYA
|
TOSHIBA | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
38WHSS042ATA0TEE/40WHSW042DTA0TEE
40WHS
|
CARRIER | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.45 | -15° | 4.20 | 3.30 | |
|
42QCE021D8S* / 38QCE021D8S*
Wall mounted
|
CARRIER | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.26 | -10° | 6.12 | 4.75 | |
|
AB125S2SR1FA(H)/1U125S2SN3FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.93 | 3.50 | 12.50 | 8.30 | ||
|
AB125S2SR1FA(H)/1U125S2SN3FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.93 | 3.50 | 12.50 | 8.30 | ||
|
RXM50A8 / FDXM50F9
RXM
|
DAIKIN | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.89 | 2.99 | -15° | 5.00 | 4.00 | |
|
M4OB-36HFN8-Q/MSAFCU-18HRFNX-QRD0GW+MSAFCU-18HRFNX-QRD0GW
M4OB-36HFN8-Q
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.35 | -10° | 10.30 | 8.40 | |
|
ZDAA-4090-09M25/HDLA-050N-09M25x2
ZDAA
|
AIRWELL | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.35 | -10° | 10.30 | 8.40 | |
|
M4OB-36HFN8-Q(H)/ACE-18HRFN8 IN+ACE-18HRFN8 IN
M4OB-36HFN8-Q
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.35 | -10° | 10.30 | 8.40 | |
|
ABH105H1ERG/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 7.00 | |
|
AB105S2SR1FA(H)/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 7.00 | |
|
UUA1 UL0 / CM18F N10
UU
|
LG | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.50 | -10° | 5.00 | 2.80 | |
|
UUA1 UL0 / CM18F N11
UU
|
LG | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.50 | -10° | 5.00 | 2.80 | |
|
AC140S2SK1FA/1U140S2SP1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.70 | 13.40 | 11.00 | ||
|
FUTO-12/FUTI-12WFI
Futura AI
|
Inventor | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.40 | -10° | 3.50 | 2.70 | |
|
IKUO-12/IKUI-12WFI
Ikura
|
Inventor | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.40 | -10° | 3.50 | 2.70 | |
|
PUZ-M200YDA/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.77 | 3.40 | -20° | 19.00 | 15.50 | |
|
MXZ-3F68VF4/MSZ-AY20VG/MSZ-AY50VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 3.81 | 3.16 | -15° | 6.20 | 6.80 | |
|
MXZ-3F68VF5/MSZ-AY20VGK(P)2/MSZ-AY50VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 3.81 | 3.16 | -15° | 6.20 | 6.80 | |
|
3N60WEAFRA-W/AS25SAT1-W+AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.00 | -10° | 5.20 | 4.60 | |
|
AS105S2SF2FA-2/1U105S2SS1FA
Wall mounted - Flair Plus
|
HAIER | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 9.00 | 7.20 | |
|
AR5VO-12/AR5VI-12WFI
Aria (AR5)
|
Inventor | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.50 | -10° | 3.50 | 2.91 | |
|
AP105S2SK1FA(H)/1U105S2SS2FA
R32 Super Match Plus - Cabinet
|
HAIER | Cabinet | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.50 | -10° | 9.20 | 7.50 | |
|
PUZ-M250YKA2/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.39 | 3.56 | 3.30 | -20° | 22.00 | 20.20 | |
|
AOEG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOHG18KATA/ARXH18KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/ARXH18KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
AOYG18KATA/ARXH18KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.30 | -15° | 5.20 | 3.80 | |
|
ABH105H1ERG(H)/1U105S2SS1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 6.00 | |
|
ABH105H1ERG(H)/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 7.00 | |
|
AC125S2SK2FA(H)/1U125S2SN3FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | 12.30 | 8.30 | ||
|
AC125S2SK2FA(H)/1U125S2SN3FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | 12.30 | 8.30 | ||
|
PUZ-ZM125YDA/PSA-M125KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.37 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PSA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.37 | 3.93 | 2.90 | -20° | 12.50 | 9.30 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.52 | 3.94 | 3.94 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Cassette | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.52 | 3.94 | 3.94 | 13.40 | 9.52 | ||
|
RAV-GM901ATP-E/RAV-HM901KRTP-E
DI
|
TOSHIBA | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.10 | -15° | 8.00 | 6.30 |