Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(2)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(78)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(4)
Fujitsu Atlantic
(2)
GENERAL
(2)
GREE
(0)
GSS
(0)
HAIER
(7)
HEC
(0)
HEIWA
(0)
HISENSE
(3)
HITACHI
(4)
IVT
(0)
Inventor
(1)
KAYSUN
(0)
LG
(10)
MIDEA
(7)
MITSUBISHI ELECTRIC
(28)
Mitsubishi Heavy Industries
(53)
NORD
(0)
Nobu
(0)
PANASONIC
(1)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(9)
THERMOR
(0)
TOSHIBA
(16)
Viessmann
(1)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AS35PBBHRA/1U35YEBGRA
Wall mounted - Pearl R290
|
HAIER | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.20 | 3.61 | -10° | 3.50 | 2.50 | |
|
MUZ-HJ50VA/MSZ-HJ50VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.20 | 3.65 | -10° | 5.00 | 3.80 | |
|
MUZ-HR35VF/MSZ-HR35VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -10° | 3.40 | 2.40 | |
|
MUZ-DW35VF/MSZ-DW35VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -10° | 3.40 | 2.40 | |
|
MUZ-HR35VF2/MSZ-HR35VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.60 | -10° | 3.40 | 2.40 | |
|
SRC50ZSP-W1/SRK50ZSP-W1
ZSP-W
|
Mitsubishi Heavy Industries | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.37 | -10° | 5.00 | 3.80 | |
|
ABH105H1ERG(H)/1U105S2SS1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 6.00 | |
|
FDC280VSA-W/FDT140VH/FDT140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 4.22 | 3.35 | 27.00 | 17.80 | ||
|
AR60F12C1KWN/AR60F12C1KWX
RAC
|
SAMSUNG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
AR70F12C1DBN/AR70F12C1DBX
RAC
|
SAMSUNG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
ABH105H1ERG(H)/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 7.00 | |
|
AR70H12CACBN/AR70H12CACBX
RAC
|
SAMSUNG | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
M4OA-27HFN8-Q(HRU)/MCA4U-09HRFNX-QRD1W(GA)+MCA4U-18HRFNX-QRD1W(GA)
M4OA-27HFN8-Q(HRU)
|
MIDEA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.50 | -10° | 7.90 | 6.30 | |
|
RAV-GV1601ATP-E1/RAV-HM1601UTP-E
DIC 1ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.46 | -15° | 13.00 | 8.00 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401UTP-E
DI 3ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
RAV-GM1401ATP-E1/RAV-HM1401UTP-E
DI
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
MUZ-DW50VF/MSZ-DW50VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MUZ-HR50VF/MSZ-HR50VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MUZ-HR50VF2/MSZ-HR50VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.48 | -10° | 5.00 | 3.80 | |
|
MOX130-12HFN8-QRD2GW/MSGPBU-12HRFN8-QRD2GW
Solunar
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
MX1-12RD1H/EF-12RD1H
Solunar
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
MX1H-12RD1H/EF-12RD1H
Solunar
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
NRO-12/NRI-12WFI
Nura
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
DURA-12RD1-OUT/DURA-12RD1-IN
Solunar
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
LINE-12RD1-OUT/LINE-12RD1-IN
Solunar
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
PRO-12RD1-OUT/PRO-12RD1-IN
Solunar
|
MIDEA | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
FDC200VSA-W/SRK100ZR-W/SRK100ZR-W
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.36 | 3.26 | 20.00 | 12.50 | ||
|
FDC125VNA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
FDC125VSA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
FDC250VSA/FDT125VH/FDT125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 4.32 | 3.78 | 24.00 | 14.20 | ||
|
FDC140VNA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
UUD1 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD3 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZTNW60GALA1
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
FDC140VNA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
FDC140VSA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
AZAS140MV / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
AZAS140MY / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
CU-Z60UBEA / CS-Z60UB4EAW
2017
|
PANASONIC | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 2.92 | -15° | 6.00 | 4.00 | |
|
MUZ-BT50VG/MSZ-BT50VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.48 | -15° | 5.00 | 3.80 | |
|
MUZ-BT50VG2/MSZ-BT50VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.48 | -15° | 5.00 | 3.80 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 |