Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(0)
AUX
(0)
BOSCH
(3)
BRYANT
(0)
Buderus
(0)
CARRIER
(1)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(16)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(18)
HEC
(0)
HEIWA
(0)
HISENSE
(4)
HITACHI
(5)
IVT
(0)
Inventor
(9)
KAYSUN
(9)
LG
(0)
MIDEA
(64)
MITSUBISHI ELECTRIC
(12)
Mitsubishi Heavy Industries
(28)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(1)
Rotenso
(2)
SAMSUNG
(2)
THERMOR
(0)
TOSHIBA
(11)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(2)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AZAS125MV / FVA125A
AZAS
|
DAIKIN | Floor standing | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.56 | 3.75 | 12.10 | 6.00 | ||
|
AZAS125MY / FVA125A
AZAS
|
DAIKIN | Floor standing | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.56 | 12.10 | 6.00 | |||
|
RPFC-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.33 | 3.55 | 3.42 | -10° | 13.76 | 12.20 | |
|
RPFC-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.78 | 2.64 | -10° | 16.30 | 11.00 | |
|
RPFC-5.0UFE1NH/RAS-5.0UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.78 | 3.24 | -10° | 12.10 | 9.50 | |
|
RAV-GM561ATP-E1/RAV-HM561FT-E
DI
|
TOSHIBA | Floor standing | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 4.00 | 3.08 | -15° | 5.00 | 2.80 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Floor standing | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.12 | 3.53 | 2.48 | -10° | 23.50 | 12.30 | |
|
RAV-GM562ATP-E/RAV-HM561FT-E
DI
|
TOSHIBA | Floor standing | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.86 | 4.01 | 3.08 | -15° | 5.00 | 2.80 | |
|
RAV-GM801ATP-E/RAV-HM801FT-E
DI
|
TOSHIBA | Floor standing | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.89 | 3.81 | 2.41 | -15° | 6.70 | 4.70 | |
|
RZASG125MV1 / FVA125A
RZASG
|
DAIKIN | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.52 | 3.64 | 3.71 | 12.10 | 6.00 | ||
|
RZASG125MY1 / FVA125A
RZASG
|
DAIKIN | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.52 | 3.64 | 3.71 | 12.10 | 6.00 | ||
|
RZASG125MY / FVA125A
RZASG
|
DAIKIN | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.52 | 3.64 | 12.10 | 6.00 | |||
|
RZASG125MV / FVA125A
RZASG
|
DAIKIN | Floor standing | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.52 | 3.64 | 12.10 | 6.00 | |||
|
RAV-GM1602AT8W-E/RAV-HM1601FT-E
DI 3ph
|
TOSHIBA | Floor standing | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.15 | 3.82 | 2.83 | -15° | 14.00 | 8.30 | |
|
AZAS140MV / FVA140A
AZAS
|
DAIKIN | Floor standing | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.40 | 3.81 | 13.40 | 7.80 | |||
|
AZAS140MY / FVA140A
AZAS
|
DAIKIN | Floor standing | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.40 | 3.81 | 13.40 | 7.80 | |||
|
AC052RXADKG/AC052RNJDKG
CAC
|
SAMSUNG | Floor standing | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.01 | -20° | 5.00 | 2.40 | |
|
RPFC-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.82 | 2.88 | -15° | 9.80 | 7.90 | |
|
ABH140K1ERG/1U140S2SP1FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.99 | 3.06 | 13.00 | 10.00 | ||
|
ABH140K1ERG/1U140S2SN1FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.62 | 3.96 | 2.63 | 13.40 | 8.50 | ||
|
ABH140K1ERG(H)/1U140S2SN1FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.62 | 3.96 | 2.63 | 13.40 | 8.50 | ||
|
AB140S2SR1FA(H)/1U140S2SN1FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.62 | 3.96 | 2.63 | 13.40 | 8.50 | ||
|
RAV-GM1401AT8P-E1/RAV-HM1401FT-E
DI 3ph
|
TOSHIBA | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 4.86 | 3.90 | 3.24 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401FT-E
DI
|
TOSHIBA | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 4.86 | 3.90 | 3.24 | -15° | 12.10 | 7.60 | |
|
PUZ-M125YKA3/PSA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.29 | 3.84 | 3.10 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA3/PSA-M125KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.29 | 3.84 | 3.10 | -15° | 12.10 | 8.50 | |
|
PUZ-M125VKA2/PSA-M125KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.29 | 3.85 | 3.10 | -15° | 12.10 | 8.50 | |
|
PUZ-M125YKA2/PSA-M125KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.29 | 3.85 | 3.10 | -15° | 12.10 | 8.50 | |
|
RAV-GM1602ATW-E/RAV-HM1601FT-E
DI
|
TOSHIBA | Floor standing | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.90 | 2.83 | -15° | 14.00 | 8.30 | |
|
MOX430U-24HFN8-QRD0W(GA)/MUE-24HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MOX430U-24HFN8-Q(GA)/MUE-24HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
CL5000L 70 E / CL5000iL CF 70 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MOX430U-24HFN8-QRD0W(GA)/MUE-24HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MOX430U-24HFN8-QRD0W(GA)/MUE-24HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
FDMX-070N-09M25/YDAX-070H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MO-24N8-Q/MUE-24NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
KUE-71 DVR13/KPC-71 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MOX430U-24HFN8-QRD0W(GA)-GR/MUE-24HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
RZASG140MV1 / FVA140A
RZASG
|
DAIKIN | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 3.81 | 3.51 | 13.40 | 7.80 | ||
|
RZASG140MY / FVA140A
RZASG
|
DAIKIN | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 3.81 | 13.40 | 7.80 | |||
|
RZASG140MV / FVA140A
RZASG
|
DAIKIN | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 3.81 | 13.40 | 7.80 | |||
|
RAV-GM1402AT8W-E/RAV-HM1401FT-E
DI 3ph
|
TOSHIBA | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.35 | 3.90 | 3.34 | -15° | 12.10 | 8.30 | |
|
AUV175UR4RC8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.30 | -10° | 16.00 | 10.00 | |
|
RZASG140MY1 / FVA140A
RZASG
|
DAIKIN | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.63 | 3.81 | 3.51 | 13.40 | 7.80 | ||
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 3.65 | 2.71 | -10° | 20.00 | 11.40 | |
|
FDC71VNP-W/FDF71VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.91 | 3.51 | -15° | 7.10 | 5.70 | |
|
FDC71VNP-W/FDF71VH1
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.85 | 3.91 | 3.51 | -15° | 7.10 | 5.70 | |
|
U7iRT-66/V7iFI-66
Floor Standing
|
Inventor | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
MOX630U-48HFN8-RRD0W(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.45 | -10° | 14.10 | 11.40 | |
|
MOX630U-48HFN8-R(GA)/MFM-48HRFN8-QRD0W
Floor Standing R32
|
MIDEA | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.45 | -10° | 14.10 | 11.40 |