Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(2)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(8)
CIAT
(5)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(30)
EQUATION
(0)
FUJI ELECTRIC
(4)
FUJITSU
(12)
Fujitsu Atlantic
(4)
GENERAL
(3)
GREE
(0)
GSS
(0)
HAIER
(32)
HEC
(0)
HEIWA
(0)
HISENSE
(1)
HITACHI
(4)
IVT
(0)
Inventor
(6)
KAYSUN
(0)
LG
(6)
MIDEA
(0)
MITSUBISHI ELECTRIC
(4)
Mitsubishi Heavy Industries
(22)
NORD
(3)
Nobu
(0)
PANASONIC
(2)
RIELLO
(5)
Rotenso
(0)
SAMSUNG
(5)
THERMOR
(0)
TOSHIBA
(7)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(3)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AZAS125MV / FHA125A
AZAS
|
DAIKIN | Ceiling suspended | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.75 | 12.10 | 6.00 | |||
|
AZAS125MY / FHA125A
AZAS
|
DAIKIN | Ceiling suspended | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.75 | 12.10 | 6.00 | |||
|
UUB1 U20 / UQ18F NA0
UU
|
LG | Console | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.81 | 3.14 | -10° | 5.00 | 3.80 | |
|
AOYG45KATA/ABYG45KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOYG45KQTA/ABYG45KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45KATA/ABHG45KRTA
ABY**K
|
GENERAL | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOHG45KQTA/ABHG45KRTA
ABY**K
|
GENERAL | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
ROG45KQTA/RYG45KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
ROG45KATA/RYG45KRTA
RYG**K
|
FUJI ELECTRIC | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOEG45KQTA/ABYG45KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOEG45KATA/ABEG45KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOEG45KATA/ABYG45KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOEG45KQTA/ABEG45KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOYG45KATA/ABYG45KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
AOYG45KQTA/ABYG45KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.80 | 3.23 | 12.10 | 9.20 | ||
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.34 | 3.61 | 3.13 | -10° | 23.50 | 12.30 | |
|
RPFC-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.45 | 3.68 | 3.06 | -10° | 14.00 | 12.00 | |
|
AZAS140MV / FHA140A
AZAS
|
DAIKIN | Ceiling suspended | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.81 | 13.40 | 7.80 | |||
|
AZAS140MY / FHA140A
AZAS
|
DAIKIN | Ceiling suspended | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.81 | 13.40 | 7.80 | |||
|
RZASG125MY / FUA125A
RZASG
|
DAIKIN | Ceiling suspended | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.84 | 12.10 | 6.00 | |||
|
RZASG125MV / FUA125A
RZASG
|
DAIKIN | Ceiling suspended | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.84 | 12.10 | 6.00 | |||
|
RZASG125MY / FHA125A
RZASG
|
DAIKIN | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.83 | 3.83 | 12.10 | 6.00 | |||
|
RZASG125MV / FHA125A
RZASG
|
DAIKIN | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.83 | 3.83 | 12.10 | 6.00 | |||
|
RZASG125MV1 / FUA125A
RZASG
|
DAIKIN | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.84 | 4.00 | 12.10 | 6.00 | ||
|
RZASG125MY1 / FUA125A
RZASG
|
DAIKIN | Ceiling suspended | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.49 | 3.84 | 4.00 | 12.10 | 6.00 | ||
|
U-140PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.78 | 3.71 | 3.70 | -15° | 14.00 | 13.60 | |
|
U-140PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.71 | 3.70 | -15° | 14.00 | 13.60 | |
|
RPFC-5.0UFE1NH/RAS-5.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.93 | 3.78 | 3.29 | -10° | 12.70 | 8.70 | |
|
RZASG140MY / FHA140A
RZASG
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.88 | 3.81 | 13.40 | 7.80 | |||
|
RZASG140MV / FHA140A
RZASG
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.88 | 3.81 | 13.40 | 7.80 | |||
|
RZASG140MV1 / FHA140A
RZASG
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.88 | 3.81 | 3.81 | 13.40 | 7.80 | ||
|
RZASG140MY1 / FHA140A
RZASG
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.88 | 3.81 | 3.81 | 13.40 | 7.80 | ||
|
AC125S2SK1FA/1U125S2SN1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.86 | 3.81 | 3.42 | 12.10 | 8.00 | ||
|
AC125S2SK1FA/1U125S2SN1FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.86 | 3.81 | 3.60 | 12.10 | 8.00 | ||
|
RZASG125MV1 / FHA125A
RZASG
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.83 | 3.83 | 3.87 | 12.10 | 6.00 | ||
|
RZASG125MY1 / FHA125A
RZASG
|
DAIKIN | Ceiling suspended | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.83 | 3.83 | 3.87 | 12.10 | 6.00 | ||
|
AC105S2SH1FA(H)/1U105S2SS1FB
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.50 | -10° | 9.50 | 6.00 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
AC140S2SK1FA/1U140S2SP1FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.70 | 13.40 | 11.00 | ||
|
AC125S2SK1FA/1U125S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.97 | 3.21 | 12.30 | 8.00 | ||
|
AC125S2SK1FA(H)/1U125S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.97 | 3.21 | 12.30 | 8.00 | ||
|
AC125S2SK2FA(H)/1U125S2SN2FA
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.97 | 3.21 | 12.30 | 8.00 | ||
|
FDC280VSA-W/FDE140VH/FDE140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.95 | 3.34 | 27.00 | 16.00 | ||
|
AC125S2SK1FA/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC125S2SK1FA(H)/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC125S2SK2FA(H)/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC 048 DB.UI/1U 048 DC.UE
R32 Super Match Plus - Convertible
|
ATLANTIC | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.21 | 12.40 | 8.00 | ||
|
PUZ-M140YKA2/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.28 | 4.04 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA2/PCA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.28 | 4.04 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA3/PCA-M140KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.28 | 4.04 | 3.50 | -15° | 13.40 | 9.40 |