Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(1)
AUX
(0)
BOSCH
(1)
BRYANT
(0)
Buderus
(0)
CARRIER
(1)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(6)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(4)
GSS
(0)
HAIER
(7)
HEC
(0)
HEIWA
(0)
HISENSE
(33)
HITACHI
(10)
IVT
(0)
Inventor
(6)
KAYSUN
(1)
LG
(12)
MIDEA
(8)
MITSUBISHI ELECTRIC
(33)
Mitsubishi Heavy Industries
(5)
NORD
(1)
Nobu
(0)
PANASONIC
(5)
PITSOS
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(3)
THERMOR
(0)
TOSHIBA
(5)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
XTRON
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOX133-09HFN8-QRD0GW/MSAGAU-09HRDN8-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
MA3-09HFN8-QRD0GW/MA3-09HRDN8-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
MOM-09N8D0-1/MAG2-07N8-1
Extreme save R32
|
MIDEA | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
MOM-09N8D0-1/MAG2-09N8-1
Extreme save R32
|
MIDEA | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
Ν2UVO-09/Ν2UVI-09WFI
Neo
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
N2VOCP-09/Ν2VICP-09WFI
Neo
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
VERO-09/VERI-09WFI
Vero
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
N3VO-09/N3VI-09WFI
Neo
|
Inventor | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 3.80 | 3.61 | -10° | 2.60 | 2.30 | |
|
DJ35LE00W/DJ35LE00G
New Comfort
|
HISENSE | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.76 | -10° | 3.50 | 3.20 | |
|
DJ35LE0AW/DJ35LE00G
New Comfort
|
HISENSE | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.76 | -10° | 3.50 | 3.20 | |
|
SUZ-M35VA/SFZ-M35VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/SFZ-M35VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
UUA1 UL0 / UQ12F NA0
UU
|
LG | Console | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.80 | -10° | 3.50 | 3.00 | |
|
UUC1 U40 / UM30F NA0
U4
|
LG | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.71 | -10° | 7.50 | 5.40 | |
|
PUZ-ZM71VHA2/PCA-M71HA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
PUZ-ZM71VHA3/PCA-M71HA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.50 | -20° | 7.10 | 4.70 | |
|
GWH24ALEXE-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 6.20 | 4.70 | |
|
PUZ-ZM125YDA2/PLA-M125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.99 | 3.50 | -20° | 12.50 | 9.30 | |
|
SUZ-M25VA/SEZ-M25DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/SEZ-M25DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SEZ-M25DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
PUZ-ZM125YDA/PLA-M125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA/PLA-M125EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PLA-M125EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.00 | 3.50 | -20° | 12.50 | 9.30 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
UI 5,3 kW MURAO SMART BLANC & UE MONO 5,3 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
S3UM12EL26A / S3NM12EL26A
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA1 U18 / A12GA1 NSE
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2 U18 / A12GA2 NSE
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2U EEU / A12GA2N EEU
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
A12GA2 U18T / A12GA2 NSET
U18A
|
LG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.30 | 3.71 | -10° | 3.70 | 2.80 | |
|
UUC1 U40 / UM30F N10
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
UUC1 U40 / UM30F N11
U4
|
LG | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -10° | 7.80 | 5.40 | |
|
ADH125H1ERG/1UH125P1ERG
Smart Power - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 12.50 | 10.00 | ||
|
ADH125H1ERG/1UH125P1ERK
Smart Power - Duct
|
HAIER | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.91 | 3.61 | 12.50 | 10.00 | ||
|
AC035RXADKG/AC035TNXDKG
CAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.10 | 3.31 | -20° | 3.50 | 2.10 | |
|
AJ052TXJ3KG / AR70F09C1AW / AR70F09C1AW
FJM
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.03 | 3.63 | -10° | 5.00 | 4.91 | |
|
UUA1 UL0 / UT12FH NQ0
UU
|
LG | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 4.00 | -10° | 3.40 | 2.80 | |
|
FDC125VSX-W/FDTC60VH/FDTC60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.95 | 3.93 | 2.20 | 12.50 | 14.00 | ||
|
AF42S3DHRA/1U42MS3FRA
Console-Monosplit
|
HAIER | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 3.80 | -10° | 4.20 | 3.50 | |
|
AF42S3DHRA(D)/1U42MS3FRA
Console-Monosplit
|
HAIER | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 3.80 | -10° | 4.20 | 3.50 | |
|
3AMW72U4RJC/HA35XU00G/HA35XU00G
Uni HA
|
HISENSE | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.21 | -10° | 6.20 | 5.00 | |
|
3AMW72U4RJC/HB35XU0AG/HB35XU0AG
Uni HB
|
HISENSE | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.21 | -10° | 6.20 | 5.00 | |
|
3AMW72U4RJC/HB35XU0BG/HB35XU0BG
Uni HB
|
HISENSE | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.21 | -10° | 6.20 | 5.00 | |
|
CU-RZ35WKE / CS-RZ35WKEW
2019
|
PANASONIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
GWH24YEXF-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.90 | -10° | 7.10 | 5.60 | |
|
CU-RZ35ZKE / CS-RZ35ZKEW
2023
|
PANASONIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
RAC-VJ50NHAE / RAD-VJ50RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.01 | 3.80 | -10° | 5.00 | 4.30 | |
|
RAV-GM1102ATW-E/RAV-HM1101FT-E
DI
|
TOSHIBA | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.22 | 3.92 | 3.61 | -15° | 9.50 | 8.30 |