Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(61)
ATLANTIC
(18)
AUX
(62)
BOSCH
(56)
BRYANT
(6)
Buderus
(16)
CARRIER
(98)
CIAT
(36)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(12)
DAIKIN
(468)
EQUATION
(2)
FUJI ELECTRIC
(102)
FUJITSU
(261)
Fujitsu Atlantic
(129)
GENERAL
(134)
GREE
(58)
GSS
(4)
HAIER
(403)
HEC
(3)
HEIWA
(3)
HISENSE
(199)
HITACHI
(97)
IVT
(0)
Inventor
(109)
KAYSUN
(60)
LG
(230)
MIDEA
(611)
MITSUBISHI ELECTRIC
(310)
Mitsubishi Heavy Industries
(221)
NORD
(39)
Nobu
(8)
PANASONIC
(133)
RIELLO
(39)
Rotenso
(8)
SAMSUNG
(107)
THERMOR
(35)
TOSHIBA
(175)
Viessmann
(22)
Vulcano
(15)
WESTPOINT
(3)
YORK
(35)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GM561ATP-E1/RAV-HM561MUTP-E
DI
|
TOSHIBA | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.37 | 3.61 | -15° | 5.00 | 2.80 | |
|
AL-H30/4DR3HB3(U) / AUMD-H30/4DR3HC2
M-Ducted
|
AUX | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 8.79 | 6.80 | |
|
RXYL90M-T1B/FDMD90M-B
M-Ducted
|
AUX | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 8.79 | 6.80 | |
|
AC71S2SG1FA(H)/1U71S2SR2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 7.10 | 5.00 | |
|
RAV-GM1101ATP-E/RAV-HM1101BTP-E
DI
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.28 | 4.19 | 3.75 | -15° | 9.50 | 7.60 | |
|
RAV-GM1101AT8P-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.28 | 4.19 | 3.75 | -15° | 9.50 | 7.60 | |
|
CU-TZ50WKE / CS-TZ50WKEW
2019
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50ZKE / CS-TZ50ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
CU-TZ50CKE / CS-TZ50CKEW
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.50 | 3.41 | -15° | 5.00 | 4.00 | |
|
AOYG24KBTB/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/ABHG24KRTA
ABH**K
|
GENERAL | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RYG24KRTA
RY**K
|
FUJI ELECTRIC | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/ABEG24KRTA
ABE**K
|
FUJITSU | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
AOEG24KBTB/ABYG24KRTA
ABY**K
|
FUJITSU | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ABYG24KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
RZASG140MY / FCAG140B
RZASG
|
DAIKIN | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 13.40 | 7.80 | |||
|
RZASG140MV / FCAG140B
RZASG
|
DAIKIN | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 13.40 | 7.80 | |||
|
AC50S2SG1FA/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
AC50S2SG1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.31 | 4.00 | 3.73 | -10° | 5.00 | 4.40 | |
|
42HK12VDS8C/38HU12VDS8C
Cassette
|
CIAT | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.65 | -10° | 3.50 | 2.75 | |
|
KC235HIDS8/AIC235HIDS8
Cassette
|
RIELLO | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.65 | -10° | 3.50 | 2.75 | |
|
42QTD012D8S*/38QUS012D8S*
Cassette
|
CARRIER | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.65 | -10° | 3.50 | 2.75 | |
|
MOX230-12HFN8-QRD0W(GA)/MCA4U-12HRFNX-QRD1W(GA)
Cassette R32
|
MIDEA | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-QD0/MCA4U-12HRFNX
Cassette R32
|
MIDEA | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
MO-12N8-Q/MCA4U-12NX
Cassette R32
|
MIDEA | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-QD0/MCA4U-12HRFNX
Cassette R32
|
MIDEA | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-Q(GA)/MCA4U-12HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
KUE-26 DVR14/KCI-35 DR15
Cassette R32
|
KAYSUN | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-QRD0W(GA)/MCA4U-12HRFNX-QRD1W(GA)-W
Cassette R32
|
MIDEA | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
MO-12N8-Q/MCA4U-12NX
Cassette R32
|
MIDEA | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CDMD-035N-09M25/YDAX-035H-09M25**
CDMD
|
AIRWELL | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
42QTD012D8SN*/38QUS012D8S-1
Cassette
|
CARRIER | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
Vitoclima100-SIC8AA100MFA035/Vitoclima100-SPROOFAA100MFP035
Cassette
|
Viessmann | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
U7RS-12/V7iCRI-12WiFiR
Cassette R32
|
Inventor | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-Q(H)/MCA4U-12HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5001L 35 E / CL5001iU 4CC 35 E
Climate 5001 L
|
BOSCH | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
SUZ-M71VA/PEAD-M71JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA/PEAD-M71JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PEAD-M71JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PEAD-M71JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -10° | 7.10 | 5.80 | |
|
42HY42VDS8C*/38HU42VD8C*
Ducted
|
CIAT | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
42QSS042D8S*/38QUS042D8S*
Ducted
|
CARRIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
DC212HIDS8*/AIC212HIDS8*
Ducted
|
RIELLO | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
AD160S2SM3FA/1U160S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.94 | 4.06 | 3.53 | 16.00 | 11.00 | ||
|
AD160S2SM3FA(H)/1U160S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.94 | 4.06 | 3.53 | 16.00 | 11.00 | ||
|
AD160S2SM9FA(H)/1U160S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.94 | 4.06 | 3.53 | 16.00 | 11.00 | ||
|
MXZ-2D53VA2/MSZ-EF18VE3W(B)(S)/MSZ-EF35VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.76 | -15° | 5.30 | 4.50 | |
|
RZA250D
RZA
|
DAIKIN | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.95 | 4.10 | 22.00 | 12.10 | |||
|
RAS-5HNC2E / RCI-5.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.13 | 4.23 | 3.98 | -20° | 11.90 | 11.93 | |
|
42HY60VDS8C/38HU60VDT8C
Ducted
|
CIAT | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 |