Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(14)
EQUATION
(0)
FUJI ELECTRIC
(1)
FUJITSU
(4)
Fujitsu Atlantic
(3)
GENERAL
(6)
GREE
(0)
GSS
(0)
HAIER
(6)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(8)
Mitsubishi Heavy Industries
(16)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(2)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AR12TXCACWKN/AR12TXCACWKX
RAC
|
SAMSUNG | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.26 | -11° | 3.50 | 2.40 | |
|
AR12BXFYDWKN/AR12BXFYDWKX
RAC
|
SAMSUNG | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.26 | -11° | 3.50 | 2.40 | |
|
AS25KBAHRA-MB/1U25MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
AS25KBAHRA-MW/1U25MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
AS25KBAHRA-W/1U25MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
AS35KBAHRA-MB/1U35MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.15 | -10° | 3.50 | 2.60 | |
|
AS35KBAHRA-MW/1U35MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.15 | -10° | 3.50 | 2.60 | |
|
AS35KBAHRA-W/1U35MS3FRA
Wall mounted - K
|
HAIER | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.15 | -10° | 3.50 | 2.60 | |
|
FDC140VNA-W/FDT71VH/FDT71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.91 | 5.12 | 4.34 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDT71VH/FDT71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.91 | 5.12 | 4.34 | 13.60 | 10.50 | ||
|
AOYH12KJCA/ASYH12KJCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
AOYH12KJCA/ASYH12KJCA-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
AOHH12KJCA/ASHH12KJCA
ASH**K
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
AOHH12KJCA/ASHH12KJCA-B
ASH**K
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
AOEH12KJCA/ASEH12KJCAL
ASE**K
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
AOEH12KJCA/ASEH12KJCALB
ASE**K
|
FUJITSU | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
AOHH12KJCA/ASHH12KJCAL
ASH**K
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
AOHH12KJCA/ASHH12KJCALB
ASH**K
|
GENERAL | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.70 | 5.10 | 4.21 | -20° | 3.40 | 2.50 | |
|
FDC125VNA-W/FDE60VH/FDE60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.44 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDE60VH/FDE60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.44 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VNA/FDE60VH/FDE60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.45 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC125VSA/FDE60VH/FDE60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.45 | 5.05 | 3.95 | 12.50 | 9.80 | ||
|
FDC140VNA-W/FDUM71VH/FDUM71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.22 | 3.69 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDUM71VH/FDUM71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.22 | 3.69 | 13.60 | 10.50 | ||
|
FDC140VNA/FDUM71VH/FDUM71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.30 | 3.69 | 13.60 | 10.50 | ||
|
FDC140VSA/FDUM71VH/FDUM71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.28 | 5.30 | 3.69 | 13.60 | 10.50 | ||
|
FDC125VNA-W/FDT60VH/FDT60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.96 | 5.20 | 4.23 | 12.50 | 9.80 | ||
|
FDC125VSA-W/FDT60VH/FDT60VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.96 | 5.20 | 4.23 | 12.50 | 9.80 | ||
|
FDC140VNA-W/SRK71ZR-W/SRK71ZR-W
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.86 | 5.31 | 3.85 | 13.60 | 10.50 | ||
|
FDC140VSA-W/SRK71ZR-W/SRK71ZR-W
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.86 | 5.31 | 3.85 | 13.60 | 10.50 | ||
|
FDC125VNA/FDT60VH/FDT60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.97 | 5.21 | 4.23 | 12.50 | 9.80 | ||
|
FDC125VSA/FDT60VH/FDT60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.97 | 5.21 | 4.23 | 12.50 | 9.80 | ||
|
RZASG140MV1
RZASG
|
DAIKIN | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.56 | 5.00 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.56 | 5.00 | 13.40 | 7.80 | |||
|
RZASG140MV
RZASG
|
DAIKIN | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.56 | 5.00 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.56 | 5.00 | 13.40 | 7.80 | |||
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 5.09 | 12.10 | 6.00 | ||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 5.09 | 12.10 | 6.00 | ||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 5.09 | 12.10 | 6.00 | |||
|
RZAG140NV1
RZAG
|
DAIKIN | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.89 | 5.03 | 5.03 | 13.40 | 9.52 | ||
|
RZAG140NY1
RZAG
|
DAIKIN | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.89 | 5.03 | 5.03 | 13.40 | 9.52 | ||
|
RZASG140MV1
RZASG
|
DAIKIN | Ceiling suspended | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.88 | 5.13 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ceiling suspended | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.88 | 5.13 | 13.40 | 7.80 | |||
|
RZASG140MV
RZASG
|
DAIKIN | Ceiling suspended | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.88 | 5.13 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Ceiling suspended | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.88 | 5.13 | 13.40 | 7.80 | |||
|
AOEH12KGCG/ASEH12KGTG
ASE**K
|
FUJITSU | Wall mounted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
AOHH12KGCG/ASHH12KGTG
ASH**K
|
GENERAL | Wall mounted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
AOYH12KGCG/ASYH12KGTG
ASY**K
|
FUJITSU | Wall mounted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.20 | 4.40 | -15° | 3.40 | 2.50 | |
|
ROH12KGCG/RSH12KGTG
RS**K
|
FUJI ELECTRIC | Wall mounted | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.20 | 4.40 | -15° | 3.40 | 2.50 |