Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(5)
ATLANTIC
(0)
AUX
(0)
BOSCH
(5)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(6)
GSS
(0)
HAIER
(8)
HEC
(0)
HEIWA
(0)
HISENSE
(7)
HITACHI
(4)
IVT
(0)
Inventor
(0)
KAYSUN
(5)
LG
(0)
MIDEA
(36)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(0)
NORD
(6)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RPFC-5.0UFE1NH/RAS-5.0UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.78 | 3.24 | -10° | 12.10 | 9.50 | |
|
RPFC-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.82 | 2.88 | -15° | 9.80 | 7.90 | |
|
ABH140K1ERG/1U140S2SP1FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.99 | 3.06 | 13.00 | 10.00 | ||
|
ABH140K1ERG/1U140S2SN1FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.62 | 3.96 | 2.63 | 13.40 | 8.50 | ||
|
ABH140K1ERG(H)/1U140S2SN1FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.62 | 3.96 | 2.63 | 13.40 | 8.50 | ||
|
AB140S2SR1FA(H)/1U140S2SN1FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.62 | 3.96 | 2.63 | 13.40 | 8.50 | ||
|
MOX430U-24HFN8-QRD0W(GA)/MUE-24HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MOX430U-24HFN8-Q(GA)/MUE-24HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
CL5000L 70 E / CL5000iL CF 70 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MOX430U-24HFN8-QRD0W(GA)/MUE-24HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MOX430U-24HFN8-QRD0W(GA)/MUE-24HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
FDMX-070N-09M25/YDAX-070H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MO-24N8-Q/MUE-24NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
KUE-71 DVR13/KPC-71 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
MOX430U-24HFN8-QRD0W(GA)-GR/MUE-24HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.00 | -10° | 7.20 | 5.50 | |
|
AUV175UR4RC8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.30 | -10° | 16.00 | 10.00 | |
|
AB140S2SR1FA(H)/1U140S2SN2FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.62 | 4.00 | 2.63 | 13.40 | 8.50 | ||
|
RPFC-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.01 | 3.55 | -15° | 6.50 | 6.00 | |
|
MOD30U-36HFN8-RRD0W(GA)/MUE-36HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-R(GA)/MUE-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
CL5000L 105 E-3 / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-RRD0W(GA)/MUE-36HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
FDMX-100N-09M25/YDAX-100H-09T35
FDMX
|
AIRWELL | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MO-36N8-R/MUE-36NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
KUE-105 DTR13/KPC-105 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-R(GA)/MUE2-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MO-36N8-R/MUE-36NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-R(H)/MUE-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
AB140S2SR1FA(H)/1U140S2SP2FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.99 | 3.06 | 13.60 | 10.00 | ||
|
ABH140K1ERG/1U140S2SP2FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.99 | 3.06 | 13.60 | 10.00 | ||
|
ABH140K1ERG(H)/1U140S2SP2FB
R32 Super Match Plus - Cassette
|
HAIER | Ceiling | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.99 | 3.06 | 13.60 | 10.00 | ||
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(GA)/MUEU-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
CL5000L 53 E / CL5000iL CF 53 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)/MUEU-18HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
FDMX-050N-09M25/YDAX-050H-09M25
FDMX
|
AIRWELL | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MO-18N8-Q/MUEU-18NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
KUE-52 DVR13/KPC-52 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-QRD0W(GA)-GR/MUEU-18HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(GA)/MUEU2-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(H)/MUE-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
MOX330U-18HFN8-Q(H)/MUEU-18HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 5.40 | 4.00 | |
|
RPFC-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.78 | -15° | 8.60 | 6.50 | |
|
MOX430U-24HFN8-QRD1W(GA)/MUE-24HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MOX430U-24HFN8-QRD1W/MUE-24HRFNX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MOX430U-24HFN8-Q1(GA)/MUE-24HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MO-24N8-Q-1/MUE-24NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
MOX430U-24HFN8-Q1(GA)/MUE2-24HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 | |
|
KUE-71 DVR14/KPC-71 DR14
Ceiling&Floor R32
|
KAYSUN | Ceiling/Floor | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.85 | -10° | 7.10 | 5.90 |