Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(2)
ATLANTIC
(0)
AUX
(0)
BOSCH
(2)
BRYANT
(0)
Buderus
(0)
CARRIER
(2)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(1)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(4)
Fujitsu Atlantic
(2)
GENERAL
(2)
GREE
(0)
GSS
(0)
HAIER
(2)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(1)
LG
(0)
MIDEA
(6)
MITSUBISHI ELECTRIC
(19)
Mitsubishi Heavy Industries
(1)
NORD
(0)
Nobu
(0)
PANASONIC
(1)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(13)
THERMOR
(0)
TOSHIBA
(2)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
ROG09KATA/RDG09KLLAP
RDG**K
|
FUJI ELECTRIC | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOHG09KATA/ARXG09KLLAP
ARXG**K
|
GENERAL | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOEG09KATA/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOYG09KATA/ARXG09KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.80 | 3.64 | -15° | 2.50 | 2.30 | |
|
MOX230-09HFN8-QRD1W(GA)/MCA4U-09HRFNX-QRD1W(GA)
Cassette R32
|
MIDEA | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
MOX230-09HFN8-Q(GA)/MCA4U-09HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
MO-09N8-Q/MCA4U-09NX
Cassette R32
|
MIDEA | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
CDMD-025N-09M25/YDAX-025R-09M25**
CDMD
|
AIRWELL | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
42QTD009D8SN*/38QUS009D8SX*
Cassette
|
CARRIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
Vitoclima100-SIC8AA100MFA027/Vitoclima100-SPROOFAA100MFP027
Cassette
|
Viessmann | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
CL5001L 26 E / CL5001iU 4CC 26 E
Climate 5001 L
|
BOSCH | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
AOYG09KATA/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
ROG09KATA/RCG09KVLA
RCG**K
|
FUJI ELECTRIC | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOHG09KATA/AUXG09KVLA
AUXG**K
|
GENERAL | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOEG09KATA/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOYG09KATA/AUXG09KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
SUZ-M25VA/SEZ-M25DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/SEZ-M25DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SEZ-M25DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 | |
|
AC035RXADKG/AC035RN1DKG
CAC
|
SAMSUNG | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.12 | -20° | 3.50 | 2.00 | |
|
AC035RXADKG/AC035BNLDKG
CAC
|
SAMSUNG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.31 | -20° | 3.50 | 2.00 | |
|
PUZ-ZM35VKA2/SLZ-M35FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.40 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SLZ-M35FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -11° | 3.60 | 2.40 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 | |
|
U-36PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 4.15 | -15° | 3.40 | 2.40 | |
|
AB25S2SA1FA/1U25S2SM1FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.72 | -10° | 2.60 | 2.10 | |
|
AB25S2SA1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.72 | -10° | 2.60 | 2.10 | |
|
SRC25ZS-W2/FDTC25VH1
ZS-W
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 4.08 | -10° | 2.50 | 2.40 | |
|
AC026RXADKG/AC026RN1DKG
CAC
|
SAMSUNG | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.26 | -20° | 2.60 | 2.00 | |
|
RXM25R9 / FFA25A9
RXM
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.24 | 3.90 | -15° | 2.50 | 2.31 | |
|
AC052RXADKG/AC052BNLDKG
CAC
|
SAMSUNG | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.45 | -20° | 5.00 | 2.40 | |
|
SUZ-M25VA/SLZ-M25FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SLZ-M25FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/MLZ-KP25VF
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/MLZ-KP25VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/MLZ-KP25VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
RAV-GM301ATP-E/RAV-HM301MUTP-E
DI
|
TOSHIBA | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.31 | 4.54 | 4.47 | -15° | 2.50 | 2.30 | |
|
RAV-GM302ATP-E/RAV-HM301MUTP-E
DI
|
TOSHIBA | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.13 | 4.57 | 4.47 | -15° | 2.50 | 2.30 | |
|
AC035RXADKG/AC035RNMDKG
CAC
|
SAMSUNG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.48 | -20° | 3.50 | 2.00 | |
|
AC052RXADKG/AC052RNNDKG
CAC
|
SAMSUNG | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.62 | -20° | 5.00 | 2.40 | |
|
MOX230-09HFN8-QRD1W(GA)/MTJ-09HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MOX230-09HFN8-Q(GA)/MTJ-09HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MO-09N8-Q/MTJU-09HNX
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
KUE-26 DVR14/KPD-26 DR15
Duct R32
|
KAYSUN | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
DDMD-025N-09M25/YDAX-025R-09M25**
DDMD
|
AIRWELL | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
42QSV009D8S*/38QUS009D8SX*
Ducted
|
CARRIER | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
Vitoclima100-SIDHAA100MFA027/Vitoclima100-SPROOFAA100MFP027
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
PUZ-ZM35VKA2/SEZ-M35DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 |