Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(13)
ATLANTIC
(11)
AUX
(0)
BOSCH
(25)
BRYANT
(1)
Buderus
(16)
CARRIER
(24)
CIAT
(3)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(7)
DAIKIN
(115)
EQUATION
(1)
FUJI ELECTRIC
(48)
FUJITSU
(88)
Fujitsu Atlantic
(55)
GENERAL
(83)
GREE
(11)
GSS
(1)
HAIER
(44)
HEC
(2)
HEIWA
(1)
HISENSE
(87)
HITACHI
(10)
IVT
(2)
Inventor
(24)
KAYSUN
(6)
LG
(71)
MIDEA
(179)
MITSUBISHI ELECTRIC
(62)
Mitsubishi Heavy Industries
(5)
NORD
(6)
Nobu
(2)
PANASONIC
(38)
RIELLO
(4)
Rotenso
(0)
SAMSUNG
(77)
THERMOR
(14)
TOSHIBA
(32)
Viessmann
(3)
Vulcano
(2)
WESTPOINT
(5)
YORK
(1)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG12KPCA/ASYG12KPCE
ASY**K
|
FUJITSU | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOYG035KPCA/ASYG035KPCA
ASY**K
|
FUJITSU | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOEG12KPCA/ASEG12KPCE
ASE**K
|
FUJITSU | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOYG12KPCA/ASYG12KPCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
AOYG035KPCA/ASYG035KPCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 3.33 | -15° | 3.40 | 2.50 | |
|
MUZ-HR25VF2/MSZ-HR25VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.71 | -10° | 2.50 | 2.00 | |
|
MUZ-HR35VF/MSZ-HR35VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -10° | 3.40 | 2.40 | |
|
MUZ-DW35VF/MSZ-DW35VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -10° | 3.40 | 2.40 | |
|
MUZ-HR35VF2/MSZ-HR35VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.60 | -10° | 3.40 | 2.40 | |
|
AOYG09KATA/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
ROG09KATA/RCG09KVLA
RCG**K
|
FUJI ELECTRIC | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOHG09KATA/AUXG09KVLA
AUXG**K
|
GENERAL | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOEG09KATA/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
AOYG09KATA/AUXG09KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.64 | -15° | 2.50 | 2.30 | |
|
RXQ25A / FTXQ25A
RXQ
|
DAIKIN | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.22 | 4.22 | 3.71 | -10° | 2.50 | 2.30 | |
|
AC20LC0EW/HC20LC00G
Max Comfort
|
HISENSE | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -10° | 2.20 | 1.80 | |
|
RAS-13B2AVG-E2/RAS-B13B2KVG-E3
SEIYA
|
TOSHIBA | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -15° | 3.30 | 2.30 | |
|
38WHSS035ATA0TEE/40WHSW035DTA0TEE
40WHS
|
CARRIER | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.00 | -15° | 3.30 | 2.30 | |
|
MOX133-09HFN8-QRD1GW/MSAGAU-09HRFN8-QRD1GW
Extreme save R32
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
MOX133-09HFN8-QRD1GW/MSAFAU-09HRFN8-QRD1GW
Forest
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
X1F-09N8D1-O/AGF-09NXD1-I
Extreme save R32
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
MOX1-09HFN8DE/MSAF-09HDN8DE
Forest
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
MCX1-09HFN8DE/MCAF-09HDN8DE
Forest
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
MOX133-09HFN8-FL/MSAGAU-09HRFN8-FL
Extreme save R32
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
O3MVO32-09F/O3MVI32-09WiFiRF
Omnia 3 (ECO)
|
Inventor | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
MOX133-09HFN8-QRD1GW-Lite/MSAGAU-09HRFN8-QRD1GW-Lite
Extreme save R32
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
KAE-C 26 DR13/KAY-CF 26 DR13
SUITE Casual
|
KAYSUN | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
MOM-09N8D1-2/MAG2-09N8-2
Extreme save R32
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
42QHG009D8SJ-2/38QHG009D8SJ-1
Wall mounted
|
CARRIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
42QHA009D8S3/38QHA009D8S3
Wall mounted
|
CARRIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
WR025HJM8-W/AIR025HJM8-1
Wall mounted
|
RIELLO | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
42BRF009B8S-1/38BRF009B8S-1
Wall mounted
|
BRYANT | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
Vitoclima 050-S IWAA050MFA026/Vitoclima 050-S OWAA050MFA026
Wall mounted
|
Viessmann | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
42QHG009D8SJ-B/38QHG009D8SJ-1
Wall mounted
|
CARRIER | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
MOX102-09HFN8/LT/MSAGAU2-09HRFNX
Extreme save R32
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
MOX131-09HFN8-QRD1GW/MSGPAU-09HRFN8-QRD1GW
Solunar
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.71 | -10° | 2.60 | 2.30 | |
|
MX1-09RD1H/EF-09RD1L
Solunar
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.71 | -10° | 2.60 | 2.30 | |
|
MX1H-09RD1H/EF-09RD1L
Solunar
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.71 | -10° | 2.60 | 2.30 | |
|
ACE-09HFN8 OUT/ACE-09HRFN8 IN
Forest
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
AF-09HFN8-O V1/AF-09HRFN8-I V1
Forest
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
MGPXV-09RD0-O/MGPXV-09RD0-I
Solunar
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.71 | -10° | 2.60 | 2.30 | |
|
MGPXVH-09RD0-O/MGPXV-09RD0-I
Solunar
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.71 | -10° | 2.60 | 2.30 | |
|
MOX1-09HFN8DG/MSAF-09HDN8DG
Forest
|
MIDEA | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
NBKU3VO-09/NBKU3VI-09WFI
Nobu
|
Nobu | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.15 | -10° | 2.60 | 2.30 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
RAC-CJ20WHAE / RAK-CJ20PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.90 | -15° | 2.00 | 1.81 | |
|
ARXF25E / ATXF25E
ARXF
|
DAIKIN | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.73 | -15° | 2.50 | 2.40 | |
|
CU-UZ35CKE / CS-UZ35CKE
2025
|
PANASONIC | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.72 | -15° | 3.30 | 2.40 | |
|
AC035RXADKG/AC035RNJDKG
CAC
|
SAMSUNG | Floor standing | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.07 | -20° | 3.50 | 2.00 | |
|
PUZ-ZM35VKA2/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.40 |