Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(13)
ATLANTIC
(11)
AUX
(0)
BOSCH
(25)
BRYANT
(1)
Buderus
(16)
CARRIER
(24)
CIAT
(3)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(7)
DAIKIN
(115)
EQUATION
(1)
FUJI ELECTRIC
(48)
FUJITSU
(88)
Fujitsu Atlantic
(55)
GENERAL
(83)
GREE
(11)
GSS
(1)
HAIER
(44)
HEC
(2)
HEIWA
(1)
HISENSE
(87)
HITACHI
(10)
IVT
(2)
Inventor
(24)
KAYSUN
(6)
LG
(71)
MIDEA
(179)
MITSUBISHI ELECTRIC
(62)
Mitsubishi Heavy Industries
(5)
NORD
(6)
Nobu
(2)
PANASONIC
(38)
RIELLO
(4)
Rotenso
(0)
SAMSUNG
(77)
THERMOR
(14)
TOSHIBA
(32)
Viessmann
(3)
Vulcano
(2)
WESTPOINT
(5)
YORK
(1)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOHH12KLTA/ASHH12KLTBL
ASH**K
|
GENERAL | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.72 | -15° | 3.40 | 2.50 | |
|
AOEH12KLTA/ASEH12KLTBL
ASE**K
|
FUJITSU | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.72 | -15° | 3.40 | 2.50 | |
|
AC035RXADKG/AC035RN1DKG
CAC
|
SAMSUNG | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.12 | -20° | 3.50 | 2.00 | |
|
SRC15ZTL-W/SRK15ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.40 | 4.76 | -10° | 1.50 | 2.30 | |
|
MUZ-WN25VA/MSZ-WN25VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.20 | 3.71 | -15° | 2.50 | 1.90 | |
|
CU-FZ25WKE / CS-FZ25WKE
2019
|
PANASONIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.20 | 4.04 | -15° | 2.50 | 1.90 | |
|
CU-BZ25XKE / CS-BZ25XKE
2022
|
PANASONIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.20 | 4.06 | -15° | 2.50 | 1.90 | |
|
CU-UZ25ZKE / CS-UZ25ZKE
2023
|
PANASONIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.20 | 4.06 | -15° | 2.50 | 1.90 | |
|
AC035RXADKG/AC035BNLDKG
CAC
|
SAMSUNG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.31 | -20° | 3.50 | 2.00 | |
|
MOX102-12HFN8-QRD0GW/MSAGBU-12HRFNX-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
42QHG012D8S*/38QHG012D8S*
Wall mounted
|
CARRIER | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.65 | 2.50 | |
|
X1-12N8D0-O/AG-12NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
CL3000i 35 E / CL3000iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
WR535HJM8*/AIR535HJM8*
Wall mounted
|
RIELLO | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.65 | 2.50 | |
|
42HC12JS8C*/38HC12JS8C*
Wall mounted
|
CIAT | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.65 | 2.50 | |
|
AG2Eco-12N8D0-O(U)/AG2Eco-12NXD0-I(U)
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG1Pro-12N8D0-O(B)/AG1Pro-12NXD0-I(B)
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Pro-12N8D0-O(U)/AG2Pro-12NXD0-I(U)
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Eco-12N8D0-O(R)/AG2Eco-12NXD0-I(R)
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
MOX102-12HFN8/LT/MSAGWBU-12HRDN8
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
MOX102-12HFN8/LT/MSAGSBU-12HRDN8
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Lite-12N8D0-O/AG2Lite -12NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Eco-12N8D0-O(A)/AG2Eco-12NXD0-I(A)
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Dura-12N8D0-O(R)/AG2Dura -12NXD0-I(R)
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
X1BP-12N8D0-O/AGBP-12NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Pro-12N8D0-O /AG2Pro-12NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Line-12N8D0-O/AG2Line-12NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Eco-12N8D0-O(B)/AG2Eco-12NXD0-I(B)
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
MOX1M02-12HFN8-QRD0GW/MSAGMBU-12HRFNX-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Eco-12N8D0-O/AG2Eco-12NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Pro-12N8D0-O(A)/AG2Pro-12NXD0-I(A)
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG1Pro-12N8D0-O(R)/AG1Pro-12NXD0-I(R)
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Line-12N8D0-O(A)/AG2Line-12NXD0-I(A)
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
MOX102-12HFN8/LT/MSAGGBU-12HRDN8
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AG2Dura-12N8D0-O/AG2Dura-12NXD0-I
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
MOM-12N8D0/MAG2-12N8
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
UE-L2C 35 / UI-L2CU M 53
Line cool
|
Vulcano | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AC166i.2-3,5 / AC166i.2-3,5 W
Logacool
|
Buderus | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
MOX102-12HFN8-GH/MSAGBU-12HRFNX-QRD0GW
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
MOX102-12HFN8-QRD0GW-GR/MSAGBU-12HRFNX-QRD0GW-GR
Extreme save R32
|
MIDEA | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
CL3000i 35 E / CL3200iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AC166i.2-3,5 / AC166i.3-3,5 W
Logacool
|
Buderus | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AOEH09KLTA/ASEH09KLTA
ASE**K
|
FUJITSU | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.73 | -15° | 2.50 | 2.30 | |
|
AOHH09KLTA/ASHH09KLTA
ASH**K
|
GENERAL | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.73 | -15° | 2.50 | 2.30 | |
|
ROH09KLTA/RSH09KLTA
RS**K
|
FUJI ELECTRIC | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.73 | -15° | 2.50 | 2.30 | |
|
AOHH09KLTA/ASHH09KLTBL
ASH**K
|
GENERAL | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.73 | -15° | 2.50 | 2.30 | |
|
AOEH09KLTA/ASEH09KLTBL
ASE**K
|
FUJITSU | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 3.73 | -15° | 2.50 | 2.30 | |
|
CU-BZ35ZKE / CS-BZ35ZKE
2023
|
PANASONIC | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.72 | -15° | 3.30 | 2.40 | |
|
ARXF20E / ATXF20E
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 | |
|
ARXF20F / ATXF20F
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 |