Filters · 2 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(9)
BRYANT
(0)
Buderus
(0)
CARRIER
(10)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(2)
Candy
(0)
DAIKIN
(27)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(10)
Fujitsu Atlantic
(6)
GENERAL
(16)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(11)
IVT
(0)
Inventor
(4)
KAYSUN
(0)
LG
(0)
MIDEA
(15)
MITSUBISHI ELECTRIC
(31)
Mitsubishi Heavy Industries
(3)
NORD
(0)
Nobu
(0)
PANASONIC
(32)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(26)
THERMOR
(0)
TOSHIBA
(40)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(5)
YORK
(0)
Mounting:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC052RXADKG/AC052RNJDKG
CAC
|
SAMSUNG | Floor standing | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.01 | -20° | 5.00 | 2.40 | |
|
AC052RXADKG/AC052TNXDKG
CAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 3.90 | 3.43 | -20° | 5.00 | 2.40 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
AC035RXADKG/AC035RNJDKG
CAC
|
SAMSUNG | Floor standing | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.07 | -20° | 3.50 | 2.00 | |
|
AC035RXADKG/AC035RN1DKG
CAC
|
SAMSUNG | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.12 | -20° | 3.50 | 2.00 | |
|
AC035RXADKG/AC035BNLDKG
CAC
|
SAMSUNG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.31 | -20° | 3.50 | 2.00 | |
|
RZAG35A / FDXM35F9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RZAG35A / FNA35A9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RAS-25E2AVG-ND/RAS-B25E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 4.45 | 4.27 | -25° | 2.50 | 2.80 | |
|
AC035RXADKG/AC035TNXDKG
CAC
|
SAMSUNG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.10 | 3.31 | -20° | 3.50 | 2.10 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 | |
|
AC026RXADKG/AC026TNXDKG
CAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.75 | -20° | 2.60 | 2.10 | |
|
AC035BXAPKG/AC035BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.13 | -25° | 3.50 | 2.00 | |
|
AC026RXADKG/AC026RN1DKG
CAC
|
SAMSUNG | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.26 | -20° | 2.60 | 2.00 | |
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
SRC40ZSX-W1/FDUM40VH
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 3.81 | 4.09 | -20° | 4.00 | 3.00 | |
|
RAS-35E2AVG-ND/RAS-B35E2KVG-ND
SEIYA
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.50 | 3.89 | -25° | 3.50 | 3.40 | |
|
AC026RXADKG/AC026RNJDKG
CAC
|
SAMSUNG | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.30 | -20° | 2.60 | 2.00 | |
|
MUZ-SF35VEH/MSZ-SF35VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.88 | -20° | 3.50 | 2.90 | |
|
AC052RXADKG/AC052BNLDKG
CAC
|
SAMSUNG | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.45 | -20° | 5.00 | 2.40 | |
|
AC026BXAPKG/AC026BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.33 | -25° | 2.60 | 2.00 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
AC026BXAPKG/AC026BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.79 | -25° | 2.60 | 2.10 | |
|
AOYG09KMCEN/ASYG09KMCEN
ASY**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOYG09KMCEN/ASEG09KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
MUZ-SF25VEH/MSZ-SF25VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.30 | 4.10 | -20° | 2.50 | 2.40 | |
|
SRC40ZSX-W1/FDE40VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.02 | 4.09 | -20° | 4.00 | 3.00 | |
|
RZAG35A / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.10 | -20° | 3.50 | 3.10 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
MUZ-EF35VEH/MSZ-EF35VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.50 | 4.19 | -20° | 3.50 | 2.90 | |
|
MUFZ-KW25VGHZ2/MFZ-KW25VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
MUZ-AY20VG/MSZ-AY20VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 4.17 | -20° | 2.00 | 2.30 | |
|
MUZ-AY20VG2/MSZ-AY20VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 4.17 | -20° | 2.00 | 2.30 | |
|
AC035RXADKG/AC035RNMDKG
CAC
|
SAMSUNG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.48 | -20° | 3.50 | 2.00 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
RAS-3M18G3AVG-E/RAS-B13G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 3.72 | -20° | 5.20 | 3.50 | |
|
38WH3M052C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 3.72 | -20° | 5.20 | 3.50 | |
|
RAS-3M18G3AVG-E/RAS-B13P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 3.72 | -20° | 5.20 | 3.50 | |
|
CL6100i 65 E / CL6100i-W 65 E
Climate 6100i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.28 | -20° | 3.50 | 3.20 | |
|
RZAG35A / FTXM35R
RZAG
|
DAIKIN | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 3.85 | -20° | 3.50 | 2.60 | |
|
AC035BXAPKG/AC035BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.04 | -25° | 3.50 | 2.50 | |
|
RAS-3M18G3AVG-E/RAS-B16G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.74 | -20° | 5.20 | 3.50 | |
|
38WH3M052C1A0TEE/40WHHW046D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.74 | -20° | 5.20 | 3.50 | |
|
RAS-3M18G3AVG-E/RAS-B16P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 3.74 | -20° | 5.20 | 3.50 | |
|
MFZ-KW25VG/MUFZ-KW25VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
RAS-13P2AVSG-E/RAS-B13J2FVG-E1
Console
|
TOSHIBA | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.70 | 3.89 | -20° | 3.50 | 3.00 |