Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(4)
ATLANTIC
(0)
AUX
(2)
BOSCH
(2)
BRYANT
(0)
Buderus
(0)
CARRIER
(1)
CIAT
(1)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(1)
GSS
(0)
HAIER
(11)
HEC
(0)
HEIWA
(0)
HISENSE
(6)
HITACHI
(0)
IVT
(1)
Inventor
(2)
KAYSUN
(2)
LG
(2)
MIDEA
(12)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(0)
NORD
(2)
Nobu
(0)
PANASONIC
(4)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(3)
TOSHIBA
(0)
Viessmann
(1)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AL-H12/4DR3HC1(U) / AUCO-H12/4DR3HA2
Console
|
AUX | Console | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.74 | -10° | 3.52 | 2.70 | |
|
RXYL35M-T1B/FDCO35-B
Console
|
AUX | Console | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 3.74 | -10° | 3.52 | 2.70 | |
|
UUA1 UL0 / UQ09F NA0
UU
|
LG | Console | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 4.20 | -10° | 2.60 | 2.80 | |
|
UUA1 UL0 / UQ12F NA0
UU
|
LG | Console | 20 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.40 | 4.00 | 3.80 | -10° | 3.50 | 3.00 | |
|
MOX230-12HFN8-QRD0W(GA)/MFA2U-12HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MFAU-12NX-1
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
U7RS-12/V7LI-12WiFiR
Console R32
|
Inventor | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
KUE-35 DVR13/KSD-35 DR14-2
ZEN Console
|
KAYSUN | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
XDMX-035N-09M25/YDAX-035H-09M25
XDMX
|
AIRWELL | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(GA)/MFA2U-12HRFNX(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MFAU-12NX-2
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(H)/MFA2U-12HRFNX(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
AF42S2SD1FA/1U42S2SM1FA
R32 Super Match Plus-Console
|
HAIER | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
AF42S2SD1FA(H)/1U42S2SM1FA
R32 Super Match Plus-Console
|
HAIER | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
AF42S2SD1FA(D)/1U42S2SM1FA
R32 Super Match Plus-Console
|
HAIER | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
NAGANO CONSOLE IC42V3-NG / E1U42L-NG
NAGANO CONSOLE
|
THERMOR | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
AF50S2SD1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.24 | -10° | 5.00 | 3.40 | |
|
AUW52U4RS7/AKT52UR4RK8
Super Inverter R32
|
HISENSE | Console | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.50 | -10° | 4.90 | 3.50 | |
|
AF25S2SD1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
AF25S2SD1FA(D)/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
NAGANO CONSOLE IC26V3-NG / E1U26LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
AW-YXDL012-H91/AW-XDL012-N91
XDL
|
AIRWELL | Console | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.96 | -10° | 3.50 | 3.20 | |
|
YDAF-035R-09M25/XDLF-035N-09M25
XDLF
|
AIRWELL | Console | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.96 | -10° | 3.50 | 3.20 | |
|
AF50S2SD1FA(D)/1U50S2SJ2FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.24 | -10° | 5.00 | 3.40 | |
|
AUW40U4RS7/AKT40UR4RK8
Super Inverter R32
|
HISENSE | Console | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.54 | -10° | 4.10 | 3.50 | |
|
AUW35U4RS8/AKT35UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.78 | -10° | 3.50 | 3.00 | |
|
AF35S2SD1FA/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AF35S2SD1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AF35S2SD1FA(D)/1U35S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
NAGANO CONSOLE IC35V3-NG / E1U35LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
AUW26U4RS8/AKT26UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.40 | 4.00 | -10° | 2.60 | 3.00 | |
|
MOX230-09HFN8-QRD0W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
KUE-26 DVR14/KSD-26 DR14-2
Console R32
|
KAYSUN | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
AUW40U4RJ8/AKT40UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.71 | -10° | 4.10 | 3.50 | |
|
AUW52U4RJ8/AKT52UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.50 | -10° | 4.90 | 3.50 | |
|
42QZY012D8S*/38QUS012D8S*
Console
|
CARRIER | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
42HC12VDS8C*/38HU12VDS8C*
Console
|
CIAT | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
CC235HIDS8*/AIC235HIDS8*
Console
|
RIELLO | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
Vitoclima100-SICNAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Console
|
Viessmann | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
MOX230-09HFN8-QRD1W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
MOX230-09HFN8-Q(GA)/MFA2U-09HRFNX(GA)
Console R32
|
MIDEA | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
MO-09N8-Q/MFAU-09NX-1
Console R32
|
MIDEA | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
U7RS-09/V7LI-09WiFiR
Console R32
|
Inventor | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
XDMX-025N-09M25/YDAX-025R-09M25**
XDMX
|
AIRWELL | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
AF25S2SD1FA/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.20 | 3.73 | -10° | 2.50 | 2.40 | |
|
MOX230-09HFN8-QRD6W(GA)/MFA2U-09HRFN8-QRD6W(GA)
Console R32
|
MIDEA | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
MOX230-09AFN8-QRD6W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
MOX230-09HFN8-QRD6W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
CL5100i CNO 25 HE / CL5100i CN 25 HE
Climate 5100i
|
BOSCH | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 |