Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(3)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(1)
GSS
(0)
HAIER
(5)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(1)
MIDEA
(0)
MITSUBISHI ELECTRIC
(4)
Mitsubishi Heavy Industries
(3)
NORD
(0)
Nobu
(0)
PANASONIC
(2)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(2)
THERMOR
(0)
TOSHIBA
(4)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC25S2SG2FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.50 | 2.80 | |
|
SUZ-M35VA/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 2.60 | |
|
AC071RXADKG/AC071RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 2.62 | -20° | 7.10 | 3.50 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
SUZ-M35VA2/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 3.00 | |
|
PUZ-ZM35VKA2/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.70 | |
|
AC25S2SG1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.71 | -10° | 2.50 | 2.80 | |
|
RAV-GM561ATP-E1/RAV-HM561CTP-E
DI
|
TOSHIBA | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.61 | 4.32 | 3.90 | -15° | 5.00 | 2.80 | |
|
SRC25ZS-W2/SRR25ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 4.46 | -10° | 2.50 | 2.50 | |
|
RZAG35B / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.10 | -10° | 3.50 | 3.10 | |
|
RAV-GM562ATP-E/RAV-HM561CTP-E
DI
|
TOSHIBA | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.34 | 3.90 | -15° | 5.00 | 2.80 | |
|
SRC40ZSX-W1/FDE40VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.02 | 4.09 | -20° | 4.00 | 3.00 | |
|
RZAG35A / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.10 | -20° | 3.50 | 3.10 | |
|
RXM35R9 / FHA35A9
RXM
|
DAIKIN | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.43 | 4.08 | -15° | 3.40 | 3.10 | |
|
AC35S2SG1FA/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
AC35S2SG1FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.20 | 3.73 | -10° | 3.50 | 3.00 | |
|
RAV-GM401ATP-E/RAV-HM401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.34 | 5.10 | 5.13 | -15° | 3.60 | 2.70 | |
|
UUA1 UL0 / UV18F N10
UU
|
LG | Ceiling suspended | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.60 | 3.70 | -10° | 5.00 | 2.90 | |
|
SRC35ZS-W2/SRR35ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.50 | 4.16 | -10° | 3.50 | 3.10 | |
|
U-36PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.40 | 4.61 | -15° | 3.50 | 2.80 | |
|
AC35S2SG2FA(H)/1U35S2SM1FA-2
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.47 | 3.73 | -10° | 3.50 | 3.00 | |
|
RAV-GM402ATP-E/RAV-HM401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 5.13 | 5.13 | -15° | 3.60 | 2.70 | |
|
GUD35ZD1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.10 | -10° | 3.50 | 3.10 | ||
|
U-36PZH3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.70 | 4.90 | 5.00 | -20° | 3.50 | 3.10 |