Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(29)
ATLANTIC
(20)
AUX
(7)
BOSCH
(63)
BRYANT
(4)
Buderus
(18)
CARRIER
(57)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(13)
DAIKIN
(170)
EQUATION
(2)
FUJI ELECTRIC
(60)
FUJITSU
(123)
Fujitsu Atlantic
(70)
GENERAL
(101)
GREE
(57)
GSS
(2)
HAIER
(169)
HEC
(4)
HEIWA
(4)
HISENSE
(170)
HITACHI
(34)
IVT
(5)
Inventor
(55)
KAYSUN
(16)
LG
(116)
MIDEA
(316)
MITSUBISHI ELECTRIC
(136)
Mitsubishi Heavy Industries
(49)
NORD
(22)
Nobu
(4)
PANASONIC
(96)
RIELLO
(11)
Rotenso
(0)
SAMSUNG
(96)
THERMOR
(29)
TOSHIBA
(105)
Viessmann
(7)
Vulcano
(4)
WESTPOINT
(14)
YORK
(11)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG12KETA /ASYG12KETE-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KMCC/ASYG12KMCE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KETA/ASYG12KETE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KETA/ASYG12KETE-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KMCC/ASYG12KMCF
ASY**K
|
Fujitsu Atlantic | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KETA/ASYG12KETF
ASY**K
|
Fujitsu Atlantic | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AOYG12KETA/ASYG12KETF-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.40 | 4.17 | -15° | 3.40 | 2.50 | |
|
AF50S2SD1FA(D)/1U50S2SJ2FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.47 | 3.24 | -10° | 5.00 | 3.40 | |
|
RXM35R9 / FFA35A9
RXM
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.38 | 4.10 | 3.50 | -15° | 3.40 | 3.10 | |
|
2U40MS3FRA/AS25PBPHRA-PRE/AS25PBPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.30 | 4.30 | -10° | 4.00 | 3.50 | |
|
2U40MS3FRA/AS25PBPHRA-PRE/AS35PBPHRA-PRE
Super Match Multi
|
HAIER | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.30 | 4.30 | -10° | 4.00 | 3.50 | |
|
AUW40U4RS7/AKT40UR4RK8
Super Inverter R32
|
HISENSE | Console | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.54 | -10° | 4.10 | 3.50 | |
|
RXM25R9 / FFA25A9
RXM
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.24 | 3.90 | -15° | 2.50 | 2.31 | |
|
AC052RXADKG/AC052BNLDKG
CAC
|
SAMSUNG | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.45 | -20° | 5.00 | 2.40 | |
|
CU-RZ25WKE / CS-RZ25WKEW
2019
|
PANASONIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
CU-RZ25ZKE / CS-RZ25ZKEW
2023
|
PANASONIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 4.13 | -15° | 2.50 | 2.40 | |
|
AC026BXAPKG/AC026BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.33 | -25° | 2.60 | 2.00 | |
|
AUW35U4RS8/AKT35UR4RK8
Turbo Inverter R32
|
HISENSE | Console | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.40 | 3.78 | -10° | 3.50 | 3.00 | |
|
CL5000i 35 E / CL5000iU W 35 E
Climate 5000i
|
BOSCH | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.30 | 3.93 | -10° | 3.30 | 2.60 | |
|
RAV-GV561ATP-E/RAV-HM561UTP-E
DIC
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.79 | -15° | 5.00 | 2.80 | |
|
AR50F15C1AHN/AR50F15C1AHX
RAC
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.50 | 3.47 | -11° | 4.30 | 2.70 | |
|
CU-2TZ41TBE/CS-TZ25ZKEW/CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 4.49 | -15° | 4.10 | 3.50 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
AOEH09KNCA/ASEH09KNCA
ASE**K
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOHH09KNCA/ASHH09KNCA
ASH**K
|
GENERAL | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOYH09KNCA/ASYH09KNCA
ASY**K
|
FUJITSU | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
ROH09KNCA/RSH09KNCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOHH09KNCA/ASHH09KNCH
ASH**K
|
GENERAL | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
AOYH09KNCA/ASYH09KNCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.40 | 4.00 | -15° | 2.50 | 2.40 | |
|
CU-2Z35TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 5.00 | -15° | 3.50 | 3.20 | |
|
SRC35ZTL-W/SRK35ZTL-W
ZTL-W
|
Mitsubishi Heavy Industries | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.70 | 4.22 | -10° | 3.50 | 2.80 | |
|
AC026BXAPKG/AC026BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.79 | -25° | 2.60 | 2.10 | |
|
MOX230-12HFN8-QRD0W(GA)/MTIU-12HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-Q(GA)/MTIU-12HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
42HY12VDS8C/38HU12VDS8C
Ducted
|
CIAT | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.78 | -10° | 3.50 | 2.70 | |
|
DC235HIDS8/AIC235HIDS8
Ducted
|
RIELLO | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.78 | -10° | 3.50 | 2.70 | |
|
CL5000L 35 E / CL5000iU D 35 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-QRD0W(GA)/MTIU-12HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
MO-12N8-Q/MTIU-12HNX
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
KUE-35 DVR13/KPD-35 DR14
ZEN Duct
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
KUE-35 DVR13/KPD-35V DR14
ZEN Duct
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
42QSS012D8S*/38QUS012D8S*
Ducted
|
CARRIER | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.78 | -10° | 3.50 | 2.70 | |
|
U7RS-12/V7DI-12WiFiR
Ducted R32
|
Inventor | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
MOX230-12HFN8-QRD0W(GA)-GR/MTIU-12HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
YUKF12BYEEBMO-1/YEKF12BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
CU-RZ35CKE / CS-RZ35CKEW
2025
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
AB25S2SC2FA/1U25S2SM1FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.47 | 3.71 | -10° | 2.50 | 2.80 | |
|
SUZ-M35VA/SEZ-M35DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA/SEZ-M35DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/SEZ-M35DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.90 | -10° | 3.50 | 2.60 |