Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(1)
ATLANTIC
(2)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(2)
EQUATION
(0)
FUJI ELECTRIC
(1)
FUJITSU
(3)
Fujitsu Atlantic
(1)
GENERAL
(2)
GREE
(6)
GSS
(0)
HAIER
(12)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(14)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
5U90S2SSS5FA/AS71S2SF1FA-MW3+AS50S2SF1FA-MW3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS50S2SJ1FA-3+AS50S2SJ1FA-3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS50XCAHRA+AS50XCAHRA
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS71S2SF2FA-3+AS50S2SF2FA-3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
ABH105H1ERG/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 7.00 | |
|
AB 036 DB.UI/1U 036 DC.UE
Cassettes
|
ATLANTIC | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.45 | -10° | 9.20 | 7.00 | |
|
AB105S2SR1FA(H)/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 7.00 | |
|
AC105S2SH1FA/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.32 | -10° | 9.50 | 7.00 | |
|
AC105S2SH2FA(H)/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.32 | -10° | 9.50 | 7.00 | |
|
ABH105H1ERG(H)/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 7.00 | |
|
AC105S2SH1FA(H)/1U105S2SS2FA
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.00 | 3.32 | -10° | 9.50 | 7.00 | |
|
AC 036 DB.UI/1U 036 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.00 | 3.23 | -10° | 9.50 | 7.00 | |
|
AD90S2SM3FA(H)/ 1U90S2SS2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.65 | -10° | 8.50 | 7.00 | |
|
AD90S2SM9FA(H)/1U90S2SS2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 9.00 | 7.00 | |
|
YDAM-090R-09M22/DDHM-090N-09M22
OASIS
|
AIRWELL | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 9.00 | 7.00 | |
|
MXZ-4F80VF4/MSZ-AY42VG/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 3.93 | 3.31 | -15° | 6.80 | 7.00 | |
|
MXZ-4F80VF5/MSZ-AY42VGK(P)2/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 3.93 | 3.31 | -15° | 6.80 | 7.00 | |
|
MXZ-5F102VF2/MSZ-AY42VG/MSZ-AY50VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.05 | 3.91 | -15° | 8.30 | 7.00 | |
|
MXZ-5F102VF3/MSZ-AY42VGK(P)2/MSZ-AY50VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.05 | 3.91 | -15° | 8.30 | 7.00 | |
|
MXZ-2F53VFHZ2/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
MXZ-2F53VFHZ3/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 4.66 | -25° | 5.30 | 7.00 | |
|
PXZ-5F85VG/MSZ-AY42VG/MSZ-AY42VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.76 | 4.20 | 3.91 | -15° | 7.80 | 7.00 | |
|
PXZ-5F85VG2/MSZ-AY42VGK(P)2/MSZ-AY42VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.76 | 4.20 | 3.91 | -15° | 7.80 | 7.00 | |
|
RZASG140MV
RZASG
|
DAIKIN | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.99 | 4.31 | 13.40 | 7.00 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.99 | 4.31 | 13.40 | 7.00 | |||
|
MXZ-4F83VF2/MSZ-AY42VG/MSZ-AY42VG
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.20 | 3.91 | -15° | 7.80 | 7.00 | |
|
MXZ-4F83VF3/MSZ-AY42VGK(P)2/MSZ-AY42VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.20 | 3.91 | -15° | 7.80 | 7.00 | |
|
MXZ-4F72VF4/MSZ-LN35VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
PXZ-4F75VG/MSZ-LN35VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
MXZ-4F72VF5/MSZ-LN35VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
PXZ-4F75VG2/MSZ-LN35VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.54 | 4.07 | 3.85 | -15° | 6.40 | 7.00 | |
|
GUD100T1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Cassette | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | -10° | 10.50 | 7.00 | ||
|
GUD100T1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Cassette | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | -10° | 10.50 | 7.00 | ||
|
GUD100PHS1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | -10° | 10.50 | 7.00 | ||
|
GUD100PHS1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | -10° | 10.50 | 7.00 | ||
|
AOYG36KBTA5/ASYG18KMTB/ASYG18KMTB
AOY**K Multi
|
FUJITSU | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
AOHG36KBTA5/ASHG18KMTB/ASHG18KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
ROG36KBTA5/RSG18KMTB/RSG18KMTB
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
AOEG36KBTA5/ASEG18KMTE/ASEG18KMTE
AOE**K Multi
|
FUJITSU | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
AOYG36KBTA5/ASYG18KMTB/ASYG18KMTB
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
GUD100ZD1/A-S/GUD100W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
GUD100ZD1/A-S/GUD100W1/NhA-X
MONOSPLITS
|
GREE | Ceiling/Floor | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | -10° | 10.00 | 7.00 | ||
|
AOEG36KBTA5/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -15° | 9.50 | 7.00 | |
|
AOHG36KBTA5/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -15° | 9.50 | 7.00 |