Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(64)
ATLANTIC
(26)
AUX
(56)
BOSCH
(63)
BRYANT
(6)
Buderus
(19)
CARRIER
(94)
CIAT
(41)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(381)
EQUATION
(4)
FUJI ELECTRIC
(115)
FUJITSU
(285)
Fujitsu Atlantic
(145)
GENERAL
(147)
GREE
(80)
GSS
(4)
HAIER
(430)
HEC
(5)
HEIWA
(4)
HISENSE
(171)
HITACHI
(76)
IVT
(1)
Inventor
(111)
KAYSUN
(65)
LG
(201)
MIDEA
(636)
MITSUBISHI ELECTRIC
(361)
Mitsubishi Heavy Industries
(180)
NORD
(38)
Nobu
(8)
PANASONIC
(133)
RIELLO
(44)
Rotenso
(8)
SAMSUNG
(103)
THERMOR
(43)
TOSHIBA
(124)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(7)
YORK
(37)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MOX230-12HFN8-Q(H)/MCA4U-12HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5001L 35 E / CL5001iU 4CC 35 E
Climate 5001 L
|
BOSCH | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
SUZ-M71VA/PEAD-M71JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA/PEAD-M71JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PEAD-M71JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PEAD-M71JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -10° | 7.10 | 5.80 | |
|
42HY42VDS8C*/38HU42VD8C*
Ducted
|
CIAT | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
42QSS042D8S*/38QUS042D8S*
Ducted
|
CARRIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
DC212HIDS8*/AIC212HIDS8*
Ducted
|
RIELLO | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
AD160S2SM3FA/1U160S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.94 | 4.06 | 3.53 | 16.00 | 11.00 | ||
|
AD160S2SM3FA(H)/1U160S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.94 | 4.06 | 3.53 | 16.00 | 11.00 | ||
|
AD160S2SM9FA(H)/1U160S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.94 | 4.06 | 3.53 | 16.00 | 11.00 | ||
|
MXZ-2D53VA2/MSZ-EF18VE3W(B)(S)/MSZ-EF35VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.20 | 3.76 | -15° | 5.30 | 4.50 | |
|
RZA250D
RZA
|
DAIKIN | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.95 | 4.10 | 22.00 | 12.10 | |||
|
42HY60VDS8C/38HU60VDT8C
Ducted
|
CIAT | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
42QSS060D8S*/38QUS060D8T*
Ducted
|
CARRIER | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
DC217HIDS8/AIC217HIDT8
Ducted
|
RIELLO | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
RAV-GM1401AT8P-E1/RAV-HM1401BTP-E
DI 3ph
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.36 | 4.19 | 3.61 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401BTP-E
DI
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.36 | 4.19 | 3.61 | -15° | 12.10 | 7.60 | |
|
AJ070HCJ2KG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.16 | 4.17 | -10° | 7.00 | 5.65 | |
|
U-250PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.48 | 3.90 | 3.80 | -20° | 22.00 | 16.70 | |
|
AUW71U4RJ7/ACT71UR4RJC8
Super Inverter R32
|
HISENSE | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.10 | 3.72 | -10° | 7.00 | 5.50 | |
|
CU-2TZ41CBE/CS-MTZ16CKE/CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.20 | 4.07 | -15° | 4.10 | 3.50 | |
|
RZAG60B / FBA60A9
RZAG
|
DAIKIN | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.10 | 3.80 | -10° | 6.00 | 4.50 | |
|
RAS-2HVRC3 / RPI-2.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.78 | 3.83 | 4.05 | -25° | 5.00 | 5.00 | |
|
RPIH-3.0UFE1NH/RAS-3.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.86 | -15° | 7.30 | 6.00 | |
|
MXZ-2E53VAHZ/MSZ-EF18VE3/MSZ-EF35VE3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.10 | 4.71 | -25° | 5.30 | 6.40 | |
|
U-200PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 3.83 | 3.55 | -20° | 19.00 | 16.00 | |
|
FDC100VSX/FDE100VH
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.84 | 4.17 | 4.18 | -20° | 10.00 | 11.20 | |
|
U-125PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.73 | 4.01 | 4.43 | -15° | 12.50 | 12.50 | |
|
RZA200D
RZA
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.83 | 3.93 | 19.00 | 11.20 | |||
|
SRC40ZSX-W1/FDE40VH
ZSX-W
|
Mitsubishi Heavy Industries | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.46 | 4.02 | 4.09 | -20° | 4.00 | 3.00 | |
|
UUB1 U20 / UT30F NB0
UU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 3.34 | -10° | 7.50 | 4.10 | |
|
U-125PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.01 | 4.43 | -15° | 12.50 | 12.50 | |
|
MOX230-09HFN8-QRD0W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
KUE-26 DVR14/KSD-26 DR14-2
Console R32
|
KAYSUN | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
CU-Z35UBEA / CS-Z35UB4EAW
2017
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.31 | -15° | 3.50 | 3.00 | |
|
U-250PZH4E8 + P‐VTVF250MC5‐PE
2025
|
PANASONIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
GWHD(42)NK6QO GWH18AGD-K6DNA1E/I+GWH24AGE-K6DNA1A/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.55 | -10° | 11.80 | 10.80 | |
|
GWHD(42)NK6ZO GWH18AGD-K6DNA1E/I+GWH24AGE-K6DNA1A/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.55 | -10° | 11.80 | 10.80 | |
|
AP71DFMHRA/1U71WEMFRA
New Cabinet RAC
|
HAIER | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.70 | -10° | 7.20 | 5.50 | |
|
V7FSO-24/V7FSI-24
Floor Standing Cabinet R32
|
Inventor | Floor standing | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 3.70 | -10° | 7.20 | 5.50 | |
|
PUZ-M71VHA/PEAD-M71JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -10° | 7.10 | 4.90 | |
|
PUZ-M71VHA/PEAD-M71JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -10° | 7.10 | 4.90 | |
|
UUD1 U30 / UV42F N20
UU
|
LG | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.60 | 12.10 | 9.50 | ||
|
UUD3 U30 / UV42F N20
UU
|
LG | Ceiling suspended | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.60 | 12.10 | 9.50 | ||
|
GUD85PHS1/A-S/GUD85W1/NhA-S
MONOSPLITS
|
GREE | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | -10° | 8.50 | 6.00 | ||
|
AOYG24KBTB/ARXG24KMLA
ARY**K
|
FUJITSU | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/ARXG24KMLA
ARH**K
|
GENERAL | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 | |
|
ROG24KBTB/RDG24KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 |