Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(1)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(23)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(5)
Fujitsu Atlantic
(2)
GENERAL
(2)
GREE
(0)
GSS
(0)
HAIER
(1)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(4)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(5)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(1)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PUZ-ZM35VKA2/SLZ-M35FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.40 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SLZ-M35FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -11° | 3.60 | 2.40 | |
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
RZAG35B / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.10 | -10° | 3.50 | 3.10 | |
|
RXM25R9 / FFA25A9
RXM
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.24 | 3.90 | -15° | 2.50 | 2.31 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
CU-2Z35TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 5.00 | -15° | 3.50 | 3.20 | |
|
AS25XCHHRA-NR/1U25KEHFRA-NR
Wall mounted - EXPERT Nordic
|
HAIER | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 4.20 | -10° | 2.60 | 3.00 | |
|
AS 007 JDB.UI/1U 007 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.75 | 4.20 | 4.80 | -10° | 2.40 | 2.50 | |
|
CU-2Z41TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.84 | -15° | 4.10 | 3.50 | |
|
RZAG35A / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.10 | -20° | 3.50 | 3.10 | |
|
RZAG35B / FBA35A9
RZAG
|
DAIKIN | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 4.10 | 4.40 | -10° | 3.50 | 4.20 | |
|
CU-Z25UBEA / CS-Z25UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 4.05 | -15° | 2.50 | 2.70 | |
|
AOYG09KVCA/AGYG09KVCA
AGY**K
|
FUJITSU | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOHG09KVCA/AGHG09KVCA
AGH**K
|
GENERAL | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
ROG09KVCA/RGG09KVCA
RG**K
|
FUJI ELECTRIC | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOEG09KVCA/AGEG09KVCA
AGE**K
|
FUJITSU | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOEG09KVCA/AGYG09KVCA
AGY**K
|
FUJITSU | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
AOYG09KVCA/AGYG09KVCA
AGY**K
|
Fujitsu Atlantic | Floor standing | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.30 | 4.30 | -15° | 2.50 | 2.60 | |
|
RZAG35A / FBA35A9
RZAG
|
DAIKIN | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.12 | 4.10 | 4.40 | -20° | 3.50 | 4.20 | |
|
3AMXM52N9 / ATXM35R / ATXM20R
3AMXM
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.29 | 4.24 | -15° | 5.20 | 4.80 | |
|
3AMXM52N9 / ATXM35A / ATXM20A
3AMXM
|
DAIKIN | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.29 | 4.24 | -15° | 5.20 | 4.80 | |
|
3MXM40A9 / FTXM20R / FTXM20R
3MXM
|
DAIKIN | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.53 | 4.24 | 4.73 | -15° | 4.00 | 4.80 | |
|
3MXM40A9 / FTXM20A / FTXM20A
3MXM
|
DAIKIN | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.53 | 4.24 | 4.73 | -15° | 4.00 | 4.80 | |
|
3MXM40A9 / CTXM15R / FTXM25R
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.52 | 4.39 | 5.15 | -15° | 4.00 | 4.20 | |
|
3MXM40A9 / CTXM15A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.52 | 4.39 | 5.15 | -15° | 4.00 | 4.20 | |
|
3MXM52A9 / CTXM15R / FTXM35R
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / CTXM15R / FTXM35R
4MWXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
3MXM52A9 / CTXM15A / FTXM35A
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / CTXM15A / FTXM35A
4MWXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXP35N9 / CTXM15A
4MWXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.30 | 4.53 | -15° | 5.00 | 4.80 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOHG09KBTB/AUXG09KVLA
AUH**K
|
GENERAL | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG09KBTB/RCG09KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOEG09KBTB/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
3MXM52A9 / FTXM25R / FTXM25R
3MXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXM25R / FTXM25R
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
3MXM52A9 / FTXM25A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXM25A / FTXM25A
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
4MWXM52A9 / FTXP25N9 / FTXP25N9
4MWXM
|
DAIKIN | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -15° | 5.00 | 4.80 | |
|
PUZ-ZM35VKA3/PLA-M35EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.61 | -11° | 3.60 | 2.70 | |
|
PUZ-ZM35VKA2/PLA-M35EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.61 | -11° | 3.60 | 2.50 | |
|
3MXM52A8 / FTXM25A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.59 | 4.38 | 4.45 | -20° | 5.00 | 4.80 | |
|
RZASG71MV1 / FHA35A9 / FHA35A9
RZASG
|
DAIKIN | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.38 | 4.38 | -10° | 6.80 | 4.50 |