Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(65)
ATLANTIC
(27)
AUX
(66)
BOSCH
(65)
BRYANT
(6)
Buderus
(20)
CARRIER
(101)
CIAT
(42)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(563)
EQUATION
(5)
FUJI ELECTRIC
(150)
FUJITSU
(353)
Fujitsu Atlantic
(180)
GENERAL
(188)
GREE
(95)
GSS
(4)
HAIER
(451)
HEC
(5)
HEIWA
(5)
HISENSE
(213)
HITACHI
(116)
IVT
(1)
Inventor
(114)
KAYSUN
(66)
LG
(316)
MIDEA
(644)
MITSUBISHI ELECTRIC
(497)
Mitsubishi Heavy Industries
(284)
NORD
(40)
Nobu
(8)
PANASONIC
(197)
RIELLO
(45)
Rotenso
(8)
SAMSUNG
(147)
THERMOR
(43)
TOSHIBA
(193)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(9)
YORK
(37)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ROG18KBTB/RCG18KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -15° | 5.20 | 4.40 | |
|
AOEG18KBTB/AUXG18KVLA
AUXG**K
|
FUJITSU | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -15° | 5.20 | 4.40 | |
|
AOYG18KBTB/AUXG18KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -15° | 5.20 | 4.40 | |
|
42HY18VDS8C/38HU18VDS8C
Ducted
|
CIAT | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
DC250HIDS8/AIC250HIDS8
Ducted
|
RIELLO | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
42QSS018D8S*/38QUS018D8S*
Ducted
|
CARRIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.00 | 3.82 | -10° | 5.40 | 4.30 | |
|
RAV-GM1101ATP-E/RAV-HM1101CTP-E
DI
|
TOSHIBA | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.27 | 3.81 | -15° | 9.50 | 7.60 | |
|
RAV-GM1101AT8P-E/RAV-HM1101CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.27 | 3.81 | -15° | 9.50 | 7.60 | |
|
NF50DBAHRA/1N50KEAFRA
NORD - Console
|
NORD | Console | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.10 | 3.71 | -10° | 5.00 | 4.20 | |
|
FDC140VNA-W/FDT140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.42 | 3.71 | 13.60 | 10.50 | ||
|
RXM60R / FTXM60R
RXM
|
DAIKIN | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.61 | -20° | 6.00 | 4.80 | |
|
RXM60A / FTXM60A
RXM
|
DAIKIN | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.30 | 3.61 | -20° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXG22KMLA
ARY**K
|
FUJITSU | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXG22KMLA
ARH**K
|
GENERAL | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXG22KMLB
ARY**K
|
FUJITSU | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOHG22KBTB/ARXG22KMLB
ARH**K
|
GENERAL | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
ROG22KBTB/RDG22KMLB
RD**K
|
FUJI ELECTRIC | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ARXG22KMLA
ARXG**K
|
FUJITSU | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOEG22KBTB/ARXG22KMLB
ARXG**K
|
FUJITSU | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXG22KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
AOYG22KBTB/ARXG22KMLB
ARY**K
|
Fujitsu Atlantic | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.74 | -15° | 6.00 | 4.80 | |
|
FDC100VNA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
FDC100VSA/FDTC50VH/FDTC50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.38 | 3.56 | -20° | 10.00 | 8.40 | |
|
RZA200D
RZA
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.16 | 4.10 | 19.00 | 11.20 | |||
|
AOYG54KBTB/AUXG54KRLB
AUXG**K
|
FUJITSU | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOYG54KRTA/AUXG54KRLB
AUXG**K
|
FUJITSU | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
ROG54KBTB/RCG54KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
ROG54KRTA/RCG54KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOHG54KBTB/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOHG54KRTA/AUXG54KRLB
AUXG**K
|
GENERAL | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOEG54KRTA/AUXG54KRLB
AUX**K
|
FUJITSU | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOEG54KBTB/AUXG54KRLB
ARX**K
|
FUJITSU | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOYG54KBTB/AUXG54KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOYG54KRTA/AUXG54KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
FDC100VNX/SRK50ZSX-W/SRK50ZSX-W
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.16 | 4.31 | -20° | 10.00 | 10.40 | |
|
FDC100VSX/SRK50ZSX-W/SRK50ZSX-W
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.16 | 4.31 | -20° | 10.00 | 10.40 | |
|
RAV-GM1602ATW-E/RAV-HM1601BTP-E
DI
|
TOSHIBA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.05 | 3.38 | -15° | 14.00 | 8.40 | |
|
GWH18YDXF-K6DNA2Y
MONOSPLITS
|
GREE | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.30 | 4.20 | -10° | 5.30 | 4.30 | |
|
RZAG100NV1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-R(GA)/MUE-55HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)/MUE-55HRFNX-QRD0W(GA)-H
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MO-55N8-R/MUE-55NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
KUE-160 DTR13/KPC-160 DR14
Zen
|
KAYSUN | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
MOE30U-55HFN8-RRD0W(GA)-GR/MUE-55HRFNX-QRD0W(GA)-GR
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
FDC125VSA/FDE125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.03 | 4.30 | 3.74 | 12.50 | 9.80 | ||
|
MOX630U-48HFN8-QRD0W(GA)/MTJ-48HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
MO-48N8-Q-1/MTJ-48NX
Duct R32
|
MIDEA | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.50 |