Filters · 1 active
Manufacturer:
AIRCLASS
(2)
AIRWELL
(65)
ATLANTIC
(27)
AUX
(66)
BOSCH
(65)
BRYANT
(6)
Buderus
(20)
CARRIER
(101)
CIAT
(42)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(15)
DAIKIN
(563)
EQUATION
(5)
FUJI ELECTRIC
(150)
FUJITSU
(353)
Fujitsu Atlantic
(180)
GENERAL
(188)
GREE
(95)
GSS
(4)
HAIER
(451)
HEC
(5)
HEIWA
(5)
HISENSE
(213)
HITACHI
(116)
IVT
(1)
Inventor
(114)
KAYSUN
(66)
LG
(316)
MIDEA
(644)
MITSUBISHI ELECTRIC
(497)
Mitsubishi Heavy Industries
(284)
NORD
(40)
Nobu
(8)
PANASONIC
(197)
RIELLO
(45)
Rotenso
(8)
SAMSUNG
(147)
THERMOR
(43)
TOSHIBA
(193)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(9)
YORK
(37)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
GUD35PS1/A-S/GUD35W1/NhA-S
MONOSPLITS
|
GREE | Ducted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | -10° | 3.50 | 3.00 | ||
|
RXP50N8 / FTXP50N9
RXP
|
DAIKIN | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.71 | -15° | 5.00 | 4.60 | |
|
PUZ-ZM140YDA2/PLA-M140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.14 | 3.50 | -20° | 13.40 | 10.60 | |
|
RAC-DJ50WHAE / RAK-DJ50RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.50 | 3.71 | -15° | 5.00 | 4.35 | |
|
AUW71U4RJ7/AUF71UR4RCPA8
Super Inverter R32
|
HISENSE | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.10 | 3.71 | -10° | 7.00 | 5.50 | |
|
CU-2Z50TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.63 | -15° | 5.00 | 4.20 | |
|
FDC100VNP-W/FDU100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.13 | 4.08 | -15° | 10.00 | 6.40 | |
|
FDC100VNP-W/FDUM100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.13 | 4.08 | -15° | 10.00 | 6.40 | |
|
PUZ-M140YKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA2/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140YKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-M140VKA3/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.62 | 4.03 | 3.15 | -15° | 13.60 | 9.40 | |
|
PUZ-ZM140YDA/PLA-M140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.64 | 4.15 | 3.50 | -20° | 13.40 | 10.60 | |
|
RAV-GP1601AT8-E/RAV-HM1601FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.98 | 3.31 | -20° | 14.00 | 12.00 | |
|
RAV-GM1102ATW-E/RAV-HM1101KRTP-E
DI
|
TOSHIBA | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.26 | -15° | 9.50 | 8.00 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.34 | 12.10 | 6.00 | |||
|
U-71PZ3E5A / S-6071PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.30 | 4.20 | -15° | 6.80 | 4.70 | |
|
U-50PZ3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.10 | 3.73 | -15° | 5.00 | 4.00 | |
|
CU-Z50CBEA / CS-Z50CD3EAW
2025
|
PANASONIC | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.35 | -15° | 5.10 | 4.00 | |
|
CU-Z50UBEA / CS-Z50UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 3.03 | -15° | 5.00 | 3.80 | |
|
42QZY012D8S*/38QUS012D8S*
Console
|
CARRIER | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
42HC12VDS8C*/38HU12VDS8C*
Console
|
CIAT | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
CC235HIDS8*/AIC235HIDS8*
Console
|
RIELLO | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
Vitoclima100-SICNAA100MFA035/Vitoclima100-SPROOFAA100MFP035
Console
|
Viessmann | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.70 | 4.20 | 4.04 | -10° | 3.70 | 2.60 | |
|
MXZ-3F54VF4/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.16 | 4.11 | -15° | 5.30 | 4.60 | |
|
MXZ-3F54VF5/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.16 | 4.11 | -15° | 5.30 | 4.60 | |
|
RAS-4HNC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.96 | 4.09 | 3.71 | -20° | 10.00 | 8.70 | |
|
MUZ-EF35VEH/MSZ-EF35VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.50 | 4.19 | -20° | 3.50 | 2.90 | |
|
SUZ-M50VA/MLZ-KP50VF
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA/MLZ-KP50VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
SUZ-M50VA2/MLZ-KP50VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 3.21 | -10° | 5.00 | 4.30 | |
|
RAV-GP561ATW-E/RAV-HM561KRTP-E
SDI
|
TOSHIBA | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.84 | 4.19 | 4.03 | -27° | 5.00 | 3.80 | |
|
RAV-GM1102ATW-E/RAV-HM1101BTP-E
DI
|
TOSHIBA | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.85 | -15° | 9.50 | 8.40 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
SCM71ZS-W/SRK20ZSX-W/SRK50ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.20 | 4.91 | -10° | 7.10 | 6.70 | |
|
RAV-GM1601ATP-E/RAV-HM1601UTP-E
DI
|
TOSHIBA | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.35 | 3.61 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601UTP-E
DI 3ph
|
TOSHIBA | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.35 | 3.61 | -15° | 14.00 | 8.00 | |
|
RXM25R9 / FNA25A9
RXM
|
DAIKIN | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 4.24 | 4.00 | -15° | 2.60 | 2.80 | |
|
MUZ-SF50VE/MSZ-SF50VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 3.41 | -15° | 5.00 | 4.20 | |
|
FDC125VNA/FDT125VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.52 | 4.38 | 3.74 | 12.50 | 9.80 | ||
|
AOYG36KBTB/AUXG36KRLB
AUY**K
|
FUJITSU | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOHG36KBTB/AUXG36KRLB
AUH**K
|
GENERAL | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
ROG36KBTB/RCG36KRLB
RC**K
|
FUJI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
ROG36KRTA/RCG36KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOHG36KRTA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOEG36KRTA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 |