Filters · 1 active
Manufacturer:
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(874)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(621)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(315)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(311)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AS50BP0EW/HB50BP0BG
Uni HB
|
HISENSE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.91 | -10° | 5.00 | 3.90 | |
|
AS50BP00W/HB50BP0AG
Uni HB
|
HISENSE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.91 | -10° | 5.00 | 3.90 | |
|
AS50BP00W/HB50BP0BG
Uni HB
|
HISENSE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.91 | -10° | 5.00 | 3.90 | |
|
AS50BP00W/HABP180AG
Uni HA
|
HISENSE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.91 | -10° | 5.00 | 3.90 | |
|
AS50BP0AW/HA50BP00G
Uni HA
|
HISENSE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.91 | -10° | 5.00 | 3.90 | |
|
AS50BP0FW/HA50BP00G
Uni HA
|
HISENSE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.91 | -10° | 5.00 | 3.90 | |
|
AS50BP0FW/HB50BP0AG
Uni HB
|
HISENSE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.91 | -10° | 5.00 | 3.90 | |
|
AS50BP0FW/HB50BP0BG
Uni HB
|
HISENSE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.91 | -10° | 5.00 | 3.90 | |
|
AS50BP0AW/HB50BP0AG
Uni HB
|
HISENSE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.91 | -10° | 5.00 | 3.90 | |
|
AS50BP0AW/HB50BP0BG
Uni HB
|
HISENSE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.91 | -10° | 5.00 | 3.90 | |
|
AS50BP0AW/HABP180AG
Uni HA
|
HISENSE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.91 | -10° | 5.00 | 3.90 | |
|
FDC100VNP-W/FDE100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.63 | 4.24 | 4.24 | -15° | 10.00 | 6.00 | |
|
PUZ-ZM100YDA/PKA-M100KAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.40 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA/PKA-M100KA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.40 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PKA-M100KA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.40 | 3.61 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PKA-M100KAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.40 | 3.61 | -20° | 9.50 | 7.80 | |
|
AOEG24KBTB/ARXH24KMTAP
ARXH**K
|
FUJITSU | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOHG24KBTB/ARXH24KMTAP
ARX**K
|
GENERAL | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXH24KMTAP
ARX**K
|
FUJITSU | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXH24KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
CU-Z42YKEA / CS-Z42YKEA
2022
|
PANASONIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 3.93 | -15° | 4.20 | 3.60 | |
|
CU-Z42YKEA-1 / CS-Z42YKEA-1
2024
|
PANASONIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 3.93 | -15° | 4.20 | 3.60 | |
|
PUZ-ZM100VDA/PEAD-M50JA2/PEAD-M50JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA/PEAD-M50JAL2/PEAD-M50JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PEAD-M50JA3/PEAD-M50JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PEAD-M50JAL3/PEAD-M50JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.30 | -20° | 9.50 | 7.80 | |
|
RXM35R9 / FVXM35A9
RXM
|
DAIKIN | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.11 | 4.63 | 3.90 | -15° | 3.40 | 2.80 | |
|
AR80F09CAAWN/AR80F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
AR80H09CAAWN/AR80H09CAAWX
RAC
|
SAMSUNG | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
FR212HIDS8*/AIC212HIDS8F*
Floor Standing
|
RIELLO | Floor standing | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.20 | 3.38 | 12.10 | 8.40 | ||
|
AUV125UR4RC8/AUW125U6RN8
Turbo Inverter R32
|
HISENSE | Ceiling | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.30 | 3.65 | -10° | 12.10 | 9.00 | |
|
MUZ-FH50VE/MSZ-FH50VE2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.60 | 4.05 | -15° | 5.00 | 4.50 | |
|
MUZ-EF42VE/MSZ-EF42VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 3.70 | -15° | 4.20 | 3.80 | |
|
RAS-18J2AVSG-E1/RAS-B18G3KVSG-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.77 | -15° | 5.00 | 4.30 | |
|
RAS-18J2AVSG-E1/RAS-B18G3KVSGB-E
SHORAI Edge
|
TOSHIBA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.77 | -15° | 5.00 | 4.30 | |
|
38WHSH050A1A0TEE/40WHHW050D1A0TEE
40WHH
|
CARRIER | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.77 | -15° | 5.00 | 4.30 | |
|
38WHSH050A1A0TEE/40WHHB050D1A0TEE
40WHH
|
CARRIER | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.77 | -15° | 5.00 | 4.30 | |
|
U-100PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 4.24 | -15° | 10.00 | 10.00 | |
|
AD35S2SM3FA(H)/1U35S2SM1FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.47 | 3.71 | -10° | 3.50 | 2.70 | |
|
RAC-VJ70WHAE / RAK-VJ70RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.60 | 3.72 | -15° | 7.00 | 5.40 | |
|
GWH18AUDXE-K6DNA1B
MONOSPLITS
|
GREE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.10 | 4.10 | |
|
GWH18AVDXE-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.30 | 4.10 | |
|
GWH18AUDXE-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.10 | 4.10 | |
|
HMIP2-50W-EUV1 / HMEP2-50-EUV1
HYOKO2
|
HEIWA | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.10 | -10° | 5.10 | 4.10 | |
|
EQO-12/EQI-12WFI
Econ IQ
|
Inventor | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 3.80 | -10° | 3.50 | 2.60 | |
|
RAS-4HRC2E / RCI-4.0FSR1
UTOPIA PRIME
|
HITACHI | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.62 | 4.36 | 4.23 | -20° | 10.00 | 8.70 | |
|
MXZ-2F53VFH4/MSZ-LN18VG2/MSZ-LN35VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 4.10 | -20° | 5.30 | 3.50 | |
|
MXZ-2F53VFH5/MSZ-LN18VG3/MSZ-LN35VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.50 | 4.10 | -20° | 5.30 | 3.50 | |
|
RAS-4HVRC2E / RPI-4.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.44 | 4.04 | 3.71 | -20° | 10.00 | 8.70 | |
|
FDC125VNX/SRK60ZSX-W/SRK60ZSX-W
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.56 | 4.02 | 12.50 | 11.40 |