Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(1)
ATLANTIC
(0)
AUX
(0)
BOSCH
(2)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(6)
EQUATION
(0)
FUJI ELECTRIC
(1)
FUJITSU
(4)
Fujitsu Atlantic
(1)
GENERAL
(3)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(1)
MITSUBISHI ELECTRIC
(8)
Mitsubishi Heavy Industries
(0)
NORD
(0)
Nobu
(0)
PANASONIC
(8)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(1)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PUZ-ZM35VKA2/SLZ-M35FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.40 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SLZ-M35FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -11° | 3.60 | 2.40 | |
|
CU-CZ25WKE / CS-CZ25WKE
2020
|
PANASONIC | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
CU-CZ25ZKE / CS-CZ25ZKE
2023
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.30 | 4.66 | -25° | 2.50 | 2.80 | |
|
RZAG35B / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.10 | -10° | 3.50 | 3.10 | |
|
RXM25R9 / FFA25A9
RXM
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.24 | 3.90 | -15° | 2.50 | 2.31 | |
|
RAS-25G3AVSG-ND/RAS-B25G3FVG-ND
Console
|
TOSHIBA | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.30 | 3.82 | -25° | 2.50 | 3.50 | |
|
AOYG09KMCEN/ASYG09KMCEN
ASY**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOYG09KMCEN/ASEG09KMCEN-B
ASE**K
|
FUJITSU | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
AOHG09KMCEN/ASHG09KMCEN-B
ASH**K
|
GENERAL | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -25° | 2.50 | 2.50 | |
|
RZAG35A / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.10 | -20° | 3.50 | 3.10 | |
|
RZAG35B / FBA35A9
RZAG
|
DAIKIN | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 4.10 | 4.40 | -10° | 3.50 | 4.20 | |
|
CU-Z25UBEA / CS-Z25UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 4.05 | -15° | 2.50 | 2.70 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
RZAG35A / FBA35A9
RZAG
|
DAIKIN | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.12 | 4.10 | 4.40 | -20° | 3.50 | 4.20 | |
|
M2OF-18HFN8-Q/MSEPBU-09HRFN8-QRD6GW+MSEPBU-09HRFN8-QRD6GW
M2OF-18HFN8-Q
|
MIDEA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
CL7000M 53/2 E /CL6001iU W 26 E +CL6001iU W 26 E
Climate 7000 M
|
BOSCH | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
ZDAB-2050-09M25/HDHC-025N-09M25x2
ZDAB
|
AIRWELL | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.60 | 4.50 | -10° | 5.30 | 4.40 | |
|
CU-NZ25YKE / CS-NZ25YKE
2023
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
CU-NZ25YKE / CS-NZ25YKE-1
2024
|
PANASONIC | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 5.00 | 5.00 | -25° | 2.50 | 2.80 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOHG09KBTB/AUXG09KVLA
AUH**K
|
GENERAL | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG09KBTB/RCG09KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOEG09KBTB/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
PUZ-ZM35VKA3/PLA-M35EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.61 | -11° | 3.60 | 2.70 | |
|
PUZ-ZM35VKA2/PLA-M35EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.61 | -11° | 3.60 | 2.50 | |
|
RZASG71MV1 / FHA35A9 / FHA35A9
RZASG
|
DAIKIN | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.33 | 4.38 | 4.38 | -10° | 6.80 | 4.50 | |
|
CU-Z25CBEA / CS-Z25CFEAW
2025
|
PANASONIC | Console | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.90 | 4.60 | 4.47 | -15° | 2.50 | 2.70 | |
|
PUZ-ZM50VKA2/PLA-ZM50EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.90 | 4.40 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/PLA-ZM50EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.90 | 4.40 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM35VKA3/PLA-ZM35EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 5.00 | -11° | 3.60 | 2.70 | |
|
PUZ-ZM35VKA2/PLA-ZM35EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.70 | 5.00 | -11° | 3.60 | 2.50 | |
|
U-36PZH3E5 / S-3650PT3E
2021
|
PANASONIC | Ceiling suspended | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.70 | 4.90 | 5.00 | -20° | 3.50 | 3.10 | |
|
U-36PZH3E5 / S-36PY3E
2022
|
PANASONIC | Cassette | 94 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.70 | 4.12 | -20° | 3.60 | 3.60 |