Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(3)
AUX
(10)
BOSCH
(13)
BRYANT
(0)
Buderus
(1)
CARRIER
(22)
CIAT
(8)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(27)
EQUATION
(0)
FUJI ELECTRIC
(26)
FUJITSU
(73)
Fujitsu Atlantic
(31)
GENERAL
(31)
GREE
(10)
GSS
(0)
HAIER
(42)
HEC
(0)
HEIWA
(0)
HISENSE
(43)
HITACHI
(66)
IVT
(0)
Inventor
(35)
KAYSUN
(36)
LG
(26)
MIDEA
(180)
MITSUBISHI ELECTRIC
(269)
Mitsubishi Heavy Industries
(94)
NORD
(4)
Nobu
(0)
PANASONIC
(86)
RIELLO
(8)
Rotenso
(8)
SAMSUNG
(27)
THERMOR
(3)
TOSHIBA
(99)
Viessmann
(8)
Vulcano
(1)
WESTPOINT
(0)
YORK
(16)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RPFC-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.33 | 3.55 | 3.42 | -10° | 13.76 | 12.20 | |
|
RPFC-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.78 | 2.64 | -10° | 16.30 | 11.00 | |
|
RPFC-5.0UFE1NH/RAS-5.0UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.78 | 3.24 | -10° | 12.10 | 9.50 | |
|
RCI-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.64 | 3.81 | 3.51 | -10° | 13.89 | 13.50 | |
|
5U105S2SS5FA/AS50PDAHRA+AS50PDAHRA
Super Match Multi
|
HAIER | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.00 | -10° | 8.20 | 7.30 | |
|
5U105S2SS5FA/AS68RDAHRA-4+AS50RCBHRA-4
Super Match Multi
|
HAIER | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.00 | -10° | 8.20 | 7.30 | |
|
IM52-NS + IM70-NS/E5U10LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.00 | -10° | 8.20 | 7.30 | |
|
5U105S2SS5FA/AS50SDBHRA-MW+AS50SDBHRA-MW
Super Match Multi
|
HAIER | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.00 | -10° | 8.20 | 7.30 | |
|
RCI-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.75 | 3.19 | -10° | 14.00 | 13.00 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.34 | 3.61 | 3.13 | -10° | 23.50 | 12.30 | |
|
RCI-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.87 | 2.89 | -10° | 16.90 | 13.50 | |
|
RPFC-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.45 | 3.68 | 3.06 | -10° | 14.00 | 12.00 | |
|
PUZ-SM140VKA3/PEAD-SM140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA3/PEAD-SM140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3/PEAD-SM140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3/PEAD-SM140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA2/PEAD-SM140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA2/PEAD-SM140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
U6RSL(5)-42
ODU + Wall Mounted
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.70 | 2.83 | -10° | 12.10 | 8.70 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Floor standing | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.12 | 3.53 | 2.48 | -10° | 23.50 | 12.30 | |
|
M5OE-42HFN8-Q/MCA4U-18HRFNX-QRD1W(GA)+MCD1-24HRFNX-QRD0W(GA)
M5OE-42HFN8-Q
|
MIDEA | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.20 | -10° | 12.30 | 9.00 | |
|
U6RSL(5)-42
ODU + Cassette
|
Inventor | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.20 | -10° | 12.30 | 9.00 | |
|
M5OE-42HFN8-Q(H)/MCA4U-18HRFNX(GA)+MCD2-24HRFNX(GA)
M5OE-42HFN8-Q
|
MIDEA | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.20 | -10° | 12.30 | 9.00 | |
|
RCI-5.0UFE1NH/RAS-5.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 3.80 | 3.45 | -10° | 12.70 | 9.00 | |
|
RAV-GV1401AT8P-E/RAV-HM1401UTP-E
DIC 3ph
|
TOSHIBA | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.90 | 3.00 | -15° | 12.10 | 7.80 | |
|
5U90S2SSS5FA/AS71S2SF1FA-MW3+AS50S2SF1FA-MW3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS50S2SJ1FA-3+AS50S2SJ1FA-3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS50XCAHRA+AS50XCAHRA
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
5U90S2SS5FA/AS71S2SF2FA-3+AS50S2SF2FA-3
Super Match Multi
|
HAIER | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.50 | -10° | 8.00 | 7.00 | |
|
AC250KNHPKH / AC250KXAPNH
CAC
|
SAMSUNG | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.00 | 3.40 | 3.24 | -20° | 25.00 | 18.50 | |
|
5U105S2SS5FA/AS71S2SF1FA-MW3+AS50S2SF1FA-MW3
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
5U105S2SS5FA/AS50S2SJ1FA-3+AS50S2SJ1FA-3
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
5U105S2SS5FA/AS50XCAHRA+AS50XCAHRA
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
5U105S2SS5FA/AS71S2SF2FA-3+AS50S2SF2FA-3
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
5U 036 NBB.UE/AS 018 JDB.UI+AS 018 JDB.UI
Super Match Multi
|
ATLANTIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
IM52V2-NG + IM70V2-NG/E5U10LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
AJ100TXJ5KH / AJ050TNAPKH / AJ050TNAPKH
FJM
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.51 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
PUHZ-SHW230YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.81 | 3.51 | 3.47 | -25° | 19.00 | 23.00 | |
|
AJ100TXJ5KG / AR60F18C1AW / AR60F18C1AW
FJM
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.58 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
5U125S2SN1FA/AS71S2SF2FA-3/AS71S2SF2FA-3
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 11.00 | 8.70 | |
|
5U125S2SN1FA/AS71XCAHRA+AS71XCAHRA
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 11.00 | 8.70 | |
|
5U125S2SN1FA/AS68PDAHRA+AS68PDAHRA
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 10.50 | 8.70 | |
|
5U125S2SN1FA/AS71SEPHRA-MW+AS71SEPHRA-MW
Super Match Multi
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 10.50 | 8.70 | |
|
RAV-GV1401ATP-E/RAV-HM1401UTP-E
DIC
|
TOSHIBA | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.90 | 3.13 | -15° | 11.50 | 7.80 | |
|
PUZ-SM140VKA2/PLA-SM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.91 | 3.30 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA2/PLA-SM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.91 | 3.30 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA3/PLA-SM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.91 | 3.30 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3/PLA-SM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.91 | 3.30 | -15° | 13.40 | 9.40 | |
|
U-140PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.78 | 3.71 | 3.70 | -15° | 14.00 | 13.60 | |
|
RAV-GM1602AT8W-E/RAV-HM1601FT-E
DI 3ph
|
TOSHIBA | Floor standing | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.15 | 3.82 | 2.83 | -15° | 14.00 | 8.30 |