Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(17)
ATLANTIC
(0)
AUX
(10)
BOSCH
(20)
BRYANT
(0)
Buderus
(2)
CARRIER
(19)
CIAT
(8)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(102)
EQUATION
(0)
FUJI ELECTRIC
(27)
FUJITSU
(88)
Fujitsu Atlantic
(44)
GENERAL
(44)
GREE
(12)
GSS
(0)
HAIER
(36)
HEC
(0)
HEIWA
(0)
HISENSE
(34)
HITACHI
(50)
IVT
(0)
Inventor
(15)
KAYSUN
(36)
LG
(47)
MIDEA
(163)
MITSUBISHI ELECTRIC
(168)
Mitsubishi Heavy Industries
(38)
NORD
(8)
Nobu
(0)
PANASONIC
(40)
RIELLO
(8)
Rotenso
(5)
SAMSUNG
(23)
THERMOR
(5)
TOSHIBA
(45)
Viessmann
(7)
Vulcano
(0)
WESTPOINT
(0)
YORK
(11)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RPFC-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.33 | 3.55 | 3.42 | -10° | 13.76 | 12.20 | |
|
RPFC-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.78 | 2.64 | -10° | 16.30 | 11.00 | |
|
UUA1 UL0 / CL18F N60
UU
|
LG | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.40 | -10° | 4.70 | 2.70 | |
|
RPFC-5.0UFE1NH/RAS-5.0UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.78 | 3.24 | -10° | 12.10 | 9.50 | |
|
UUA1 UL0 / CL12F N50
UU
|
LG | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.71 | -10° | 3.40 | 2.90 | |
|
AD71S2SS1FA/1U71S2ST1FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.41 | 3.80 | 3.34 | -10° | 7.10 | 5.00 | |
|
AZAS71MV1 / ADEA71A
AZAS
|
DAIKIN | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.44 | 3.81 | 3.62 | -10° | 6.80 | 4.50 | |
|
RZASG71MV1 / FBA35A9 / FBA35A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.43 | 3.82 | 3.82 | -10° | 6.80 | 4.50 | |
|
RZASG100MV1 / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | 3.80 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | 3.80 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | -10° | 9.50 | 6.00 | ||
|
PUZ-SM140VKA3/PEAD-SM140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA3/PEAD-SM140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3/PEAD-SM140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3/PEAD-SM140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA2/PEAD-SM140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA2/PEAD-SM140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.84 | 3.64 | 3.50 | -15° | 13.40 | 9.40 | |
|
UUA1 UL0 / CM18F NA0
UU
|
LG | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.80 | 3.50 | -10° | 5.00 | 2.80 | |
|
AZAS71MV1 / FBA71A9
AZAS
|
DAIKIN | Ducted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.57 | 3.81 | 3.73 | -10° | 6.80 | 4.50 | |
|
AZAS100MV1 / ADEA100A
AZAS
|
DAIKIN | Ducted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.13 | 3.81 | 4.63 | -10° | 9.50 | 6.00 | |
|
AZAS100MV1 / FBA100A
AZAS
|
DAIKIN | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.81 | 4.77 | -10° | 9.50 | 6.00 | |
|
AZAS100MY1 / FBA100A
AZAS
|
DAIKIN | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.81 | 4.77 | -10° | 9.50 | 6.00 | |
|
AC250KNHPKH / AC250KXAPNH
CAC
|
SAMSUNG | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.00 | 3.40 | 3.24 | -20° | 25.00 | 18.50 | |
|
5MWXM68A9 / FBA35A9 / FBA35A9
5MWXM
|
DAIKIN | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.80 | 3.29 | -15° | 6.80 | 3.60 | |
|
RXM60R / FDXM60F9
RXM
|
DAIKIN | Ducted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.80 | 3.21 | -15° | 6.00 | 4.60 | |
|
AZAS100MY / ADEA100A
AZAS
|
DAIKIN | Ducted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.55 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / ADEA100A
AZAS
|
DAIKIN | Ducted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.55 | 3.81 | -10° | 9.50 | 6.00 | ||
|
ARXM71R / ADEA71A
ARXM
|
DAIKIN | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.35 | 3.80 | 3.49 | -15° | 6.80 | 6.00 | |
|
ARXM71A / ADEA71A
ARXM
|
DAIKIN | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.35 | 3.80 | 3.49 | -15° | 6.80 | 6.00 | |
|
AOYG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
ROG14KATA/RDG14KLLAP
RDG**K
|
FUJI ELECTRIC | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG14KATA/ARXG14KLLAP
ARXG**K
|
GENERAL | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXG14KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AZAS100MV / FBA100A
AZAS
|
DAIKIN | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MY / FBA100A
AZAS
|
DAIKIN | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
UUB1 U20 / UM30F N10
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUB1 U20 / UM30F N11
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
UUB1 U20 / UM30F NA0
UU
|
LG | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.56 | -10° | 7.50 | 4.30 | |
|
RAV-GV1401AT8P-E+RAV-HM1401BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.00 | -15° | 12.10 | 7.80 | |
|
RAV-GV1101ATP-E/RAV-HM1101BTP-E
DIC
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.33 | -15° | 9.50 | 7.60 | |
|
RPFC-4.0UFE1NH/RAS-4.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.87 | 3.82 | 2.88 | -15° | 9.80 | 7.90 | |
|
RAV-GV1401ATP-E/RAV-HM1401BTP-E
DIC
|
TOSHIBA | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.05 | -15° | 11.50 | 7.80 | |
|
PUZ-SM125VKA3/PEAD-SM125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125VKA3/PEAD-SM125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125YKA3/PEAD-SM125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125YKA3/PEAD-SM125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125VKA2/PEAD-SM125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 | |
|
PUZ-SM125YKA2/PEAD-SM125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.86 | 3.50 | -15° | 12.10 | 8.50 |