Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(7)
HITACHI
(3)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(0)
NORD
(6)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AUV175UR4RC8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.30 | -10° | 16.00 | 10.00 | |
|
AUV140UR4RC8/AUW140U6RN8
Turbo Inverter R32
|
HISENSE | Ceiling | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.30 | 2.90 | -10° | 13.50 | 9.00 | |
|
AUV125UR4RC8/AUW125U6RN8
Turbo Inverter R32
|
HISENSE | Ceiling | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.00 | 4.30 | 3.65 | -10° | 12.10 | 9.00 | |
|
AUV140UR4RC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
AUV140UR4RC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
AUV125UR4RC8/AUW125U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
AUV125UR4RC8/AUW125U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
RAC-XJ25FHAE / RAF-XJ25RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 8.50 | 4.60 | 4.50 | -20° | 2.50 | 2.77 | |
|
RAC-XJ35FHAE / RAF-XJ35RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 8.20 | 4.61 | 3.90 | -20° | 3.50 | 3.02 | |
|
RAC-XJ50FHAE / RAF-XJ50RHAE
RAC-XJ-FHAE airHome Floor
|
HITACHI | Floor | — No score: too few class peers or too few declared metrics. Why? | 7.30 | 4.30 | 3.90 | -20° | 5.00 | 4.19 | |
|
NB71MBAHRA/1N71WEAFRA-W
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 6.10 | 4.05 | 3.15 | -10° | 6.20 | 4.60 | |
|
NB25MBAHRA/1N25MEAFRA
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 7.50 | 4.20 | 3.80 | -10° | 2.50 | 2.60 | |
|
NB35MBAHRA/1N35MEAFRA
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 7.80 | 4.10 | 3.80 | -10° | 3.50 | 2.80 | |
|
NB35MBAHRA/1N35MEAFRA-W
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 7.80 | 4.10 | 3.80 | -10° | 3.50 | 2.80 | |
|
NB50MBAHRA/1N50KEAFRA
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 6.30 | 4.05 | 3.40 | -10° | 5.00 | 4.00 | |
|
NB50MBAHRAA/1N50KEAFRA-W
NORD - Mini Cassette
|
NORD | Mini cassette | — No score: too few class peers or too few declared metrics. Why? | 6.30 | 4.05 | 3.40 | -10° | 5.00 | 4.00 |